240 Riverside Drive
Manhattan, NY 10025BBL 1-01887-0001Map
Owner of record: 243 Riverside Drive Corp
240 Riverside Drive is an elevator apartment building built in 1916 in Manhattan, 10025. It has 47 residential units across 12 floors. The owner of record is 243 Riverside Drive Corp. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 45
- ECB violations
- 9
- HPD complaints
- 2
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 45
- Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tst
Sep 6, 2019
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Jul 2, 2019
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jul 2, 2019
Dob violation - resolved - Facade safety program facade required
Fisp-facade safety program facade required
Feb 20, 2018
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst
Jan 26, 2018
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst
Jan 26, 2018
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 21, 2016
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 21, 2016
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jul 15, 2014
Dob violation - resolved - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2012 inspection report
May 15, 2014
Dob violation - dismissed
Show 35 more ↓
- Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2012 inspection report
May 15, 2014
Dob violation - dismissed - No report and / or late filing (facade) facade required
Failed to file fisp cycle 7b technical report by 08/21/2012
Aug 30, 2013
Dob violation - active - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2011 inspection report
Mar 1, 2013
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2011 inspection report
Mar 1, 2013
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Dec 13, 2012
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Dec 13, 2012
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
May 19, 2011
Dob violation - active - Elevator elevatorrequired
E-elevator elevatorrequired
Oct 14, 2010
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Nov 18, 2009
Dob violation - resolved - Elevator elevatoroptional
Ll1081-local law 10/81 - elevator elevatoroptional
Feb 27, 2009
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 6, 2008
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 6, 2008
Dob violation - resolved - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Jan 3, 2008
Dob violation - dismissed - Facade facade optional
Ll1198-local law 11/98 - facade facade optional
Nov 30, 2007
Dob violation - dismissed - Facade facade optional
Ll1198-local law 11/98 - facade facade optional
Nov 30, 2007
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Jan 19, 2007
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Oct 3, 2006
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Oct 3, 2006
Dob violation - resolved - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Jan 6, 2006
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Apr 11, 2005
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 30, 2003
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 30, 2003
Dob violation - resolved - Facade facade required
L1198-local law 11/98 - facade facade required
Aug 8, 2002
Dob violation - dismissed - Facade facade optional
Ll10/80-local law 10/80 - facade facade optional
Feb 26, 2002
Dob violation - dismissed - Elevator elevatorrequired
1p9038
May 3, 2001
Dob violation - resolved - Elevator elevatorrequired
1p9039
May 3, 2001
Dob violation - resolved - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Mar 16, 1999
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
May 4, 1998
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Sep 16, 1997
Dob violation - dismissed - Elevator elevatoroptional
Ll1081-local law 10/81 - elevator elevatoroptional
Mar 8, 1996
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Aug 29, 1995
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Mar 18, 1994
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Mar 18, 1993
Dob violation - dismissed - Elevator elevatorrequired
(51)provide counterweight buffers & provide proper clearance counterweight to buffer
Aug 1, 1988
Dob violation - resolved - Facade facade optional
Ll10/80-local law 10/80 - facade facade optional
Jul 1, 1988
Dob violation - active
ECB violations · 9
- Class - 2
Failure to maintain exterior building facade and appurtenances.note:observed multiple air conditioners installed on exposures 1 and 4 west and south elevations with improper support of plywood and pieces of woo
May 28, 2020
Resolve - Class - 1
Failure to take and provide safety measures sidewalk shed/netting etc where required to protect and secure public safety from documented unsafe facade as per 1rcny 103.04. two facade technical report (fisp 3 no
Feb 23, 2018 · Penalty $2,400
Resolve - Class - 2
Failure to file an acceptable sixth round technical report in compliance w/ code provisions periodic insp of exterior walls and appurtenances as required by article 28.302 and the dob rules and regulations rem:
Jul 17, 2010
Resolve - Non-hazardous
Failure to submit a fifth round technical report periodic inpection of exterior walls and appurtenances as required by local law 11 of 1998 and the dept of bld rules and regulations remedy file the required rep
May 30, 2003
Resolve - Hazardous
Failure to file an amended round five report acceptable to this department, indicating correction of unsafe conditions described in initial ll11/98 report. remedy: file an amended report following remedial repa
May 23, 2003 · Penalty $1,750
Resolve - Hazardous
No licensed concrete testes upon inspection at the above property the 4th floor was being poured and there is no licensed concrete tester present.remedy:provide licensed concrete tester as per code
Apr 23, 2003 · Penalty $500
Resolve - Hazardous
Failure to file an ammended round five report acceptable to this department pursuant to rule r.c.n.y. 32-03b(5),indicating correction of hazardous conditions described in initial ll11/98report remedy file an am
May 3, 2002 · Penalty $400
Resolve - Non-hazardous
73#,22d,46t,48t,47l,73o,73# perform 5 year test. properly tag device, and file elv3 form.
Jun 24, 1991
Resolve - Non-hazardous
73#,46t,48t,73o,73# perform 5 year test, properly tag device, and file elv 3 form.
Jun 24, 1991
Resolve
Complaints
- Plumbing
Water-leaks
Jan 18, 2007 · Apt 1B
Close - Paint/plaster
Ceiling
Jan 18, 2007 · Apt 1B
Close
Sales history
No recorded sales in our data
Building details
- Building type
- Elevator apartment building (D4)
- Year built
- 1916
- Floors
- 12
- Residential units
- 47
- Building area
- 41,132 ft²
- Lot area
- 5,450 ft²
- Zoning
- R10A
- Community board
- 107
- Council district
- 7
- Block / lot
- 1887 / 1
- Assessed value
- $3,335,400
- Landmark / historic district
- Riverside-West End Historic District Extension II
HPD registration #102204, last renewed Aug 26, 2025.
Questions about 240 Riverside Drive
Who owns 240 Riverside Drive?
The owner of record in NYC Department of City Planning PLUTO data is 243 Riverside Drive Corp.
Does 240 Riverside Drive have violations?
NYC HPD has no housing violations on record for this property.
Is 240 Riverside Drive rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 240 Riverside Drive built?
City records list 1916 as the year it was built.
How many apartments are in 240 Riverside Drive?
It has 47 residential units.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.