roofy

1105 Lexington Avenue

Manhattan, NY 10075BBL 1-01412-0021Map

Owner of record: Allied Xxxx LLC

1105 Lexington Avenue is an elevator apartment building built in 1910 in Manhattan, 10075. It has 10 residential units across 4 floors. The owner of record is Allied Xxxx LLC. HPD has recorded 8 housing violations here, most recently on June 4, 2025.

HPD violations
8
DOB violations
5
ECB violations
24
HPD complaints
19

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
Last violation Jun 4, 2025

Date of the most recent HPD inspection that found a problem.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 8

  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Jun 4, 2025

    Closed — Violation dismissed
  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Apr 1, 2024

    Closed — Violation dismissed
  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Mar 15, 2023

    Closed — Violation dismissed
  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Feb 15, 2022

    Closed — Violation dismissed
  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Feb 15, 2022

    Closed — Violation dismissed
  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Apr 1, 2021

    Closed — Violation dismissed
  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Oct 9, 2018

    Closed — Violation dismissed
  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Oct 1, 2015

    Closed — Violation dismissed

DOB building violations · 5

  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Mar 3, 2021

    Dob violation - dismissed
  • Construction other optional

    C-construction other optional

    Mar 20, 2001

    Dob violation - dismissed
  • Construction other optional

    C-construction other optional

    Mar 19, 2001

    Dob violation - dismissed
  • Zoning none

    Z-zoning none

    Jun 21, 1999

    Dob violation - dismissed
  • Zoning none

    Z-zoning none

    Jun 21, 1999

    Dob violation - dismissed

ECB violations · 24

  • Class - 2

    Failure to file required annual boiler inspection reports for low-pressure boiler 071688 in accordance with the rules of the department. 1rcny and 103-01(d)(1) requires that an annual inspection report for low-

    Jun 7, 2024 · Penalty $625

    Resolve
  • Class - 2

    At time of inspection, observed sidewalk shed and supported scaffold at exposure 1. upon requesting daily inspection check list it was not provided. observed some defects on sidewalk shed that were not recorde

    Feb 22, 2023

    Resolve
  • Class - 2

    Failure to maintain supported scaffold in code complying manner. at time of inspection observed at exp. 1 and 3 a supported scaffold. observed unsecured planks at different levels planks not resting on bicycle

    Feb 22, 2023

    Resolve
  • Class - 2

    At time of inspection, observed a supported scaffold at exposure 1. at 4 floor observed shoring system use to brace supported scaffold. upon requesting approved drawing a detail page with option used was provid

    Feb 22, 2023 · Penalty $1,250

    Resolve
  • Class - 1

    Failure to institute/maintain safety measures. (bc 3301.2). at time of inspection observed at roof level worker on baker scaffolding working up and over guard rail at leading edge without ppe (harness) tied off

    Feb 9, 2023

    Resolve
  • Class - 1

    Failure to institute/maintain safety equipment measures or temporary construction-no guard rails. at time of inspection observed at roof level area open unsecured where perimeter at expo$ 2/3/4 leading edge mis

    Feb 9, 2023 · Penalty $2,500

    Resolve
  • Class - 1

    Work does not conform to approved plans-sidewalk shed.at time of inspection of 6 story active jobsite permit #123069909 observed sws at exp #1 review of approved drawings shed missing crossbraces creating hazar

    Mar 31, 2022 · Penalty $2,500

    Resolve
  • Class - 1

    Work does not conform to approved plans-pipe scaffold.at time of inspection of 6 story active jobsite under permit #123069909 observed pipe scaffold at exp #1 #3 review of approved drawings exp #3 pipe scaffold

    Mar 31, 2022 · Penalty $2,500

    Resolve
  • Class - 1

    Inadequate inspection logs for supported scaffold.at time of inspection of 6 story building permit #123069909 observed supported scaffold at exp #1 #3 multiple issues work not build according to plans review of

    Mar 31, 2022 · Penalty $2,500

    Resolve
  • Class - 1

    Sec. bc3301.13.12 failure to designated &/or have a construction superintendent/c.s. present at site as required or competent person. at time of inspection of this 6 sty bldg,i observed active worksite. 5 worke

    Jul 13, 2021 · Penalty $10,000

    Resolve
Show 14 more ↓
  • Class - 1

    Sec. bc 3303.9 obstructed egress. at time of inspection this 6 sty bldg,i observed active worksite w/5 workers on the 6th fl doing masonry work. very difficult to access the 6th fl as ladder egress is 100% obst

    Jul 13, 2021 · Penalty $2,500

    Resolve
  • Class - 2

    Sec. bc3314.9.2 unsafe scaffold-foundation-base plates. at time of inspection of this 6 sty bldg,i observed masonry scaffold on the 6th fl used by workers. scaffold had no baseplates. bc 3314.9.2 clearly stipul

    Jul 13, 2021 · Penalty $625

    Resolve
  • Class - 2

    Inadequate work/storage zone. at the time of inspection of proposed 6 story building enlargement active jobsite observed approx 15' of roadway width occupied at exp#1 by the contractor storing materials/unloadi

    Jul 12, 2021 · Penalty $625

    Resolve
  • Class - 1

    Work does not conform to approved construction documents and/or amendments-structural framing plans. at time of inspection at a 6 story alteration,i observed on 2nd-4th fl c-joist sistering joist beams not comp

    Dec 10, 2020 · Penalty $2,500

    Resolve
  • Class - 1

    3314.9 supported scaffold shall meet its requirements per-sections 3314.9.1 thru 3314.9.4. at time of inspection at a 6 story alteration,i observed on the 2nd fl roof/setback expo 3 pipe scaffold erected to 4th

    Dec 10, 2020 · Penalty $625

    Resolve
  • Class - 1

    3305.2.2 structural steel assembly/fabrication. at time of inspection at a 6 story alteration,i observed from 1st-4th fl steel assembly/fabrication/connection modified. upon request for approved drawings and de

    Dec 10, 2020 · Penalty $625

    Resolve
  • Class - 1

    Failure to maintain/display onsite documents required by chapter 33.attime of inspection of an active job no detail indicating how the 2x6 shoring should be layed out.when i ask for design drawing shoring that

    Mar 11, 2020 · Penalty $1,250

    Resolve
  • Class - 2

    Failure to provide drawings for temporary construction-temp const ladders. at time of inspection i observed ongoing const activity w/ const ladders installed to provide secondary egress. when requested for deta

    Dec 3, 2019 · Penalty $312

    Resolve
  • Class - 1

    28-116.2.3 failure to provide required special inspection report at time of inspection. at time of inspection i observed an active jobsite w/ structural steel installed up to the 4th fl. upon request for inspec

    Dec 3, 2019 · Penalty $625

    Resolve
  • Class - 1

    Failure to institute/maintain safety equipment measures for temporary const(no guardrails). at time of my inspection at an active jobsite i observed at exp#3 rear 2nd story roof exposed leading edge w/ no prote

    Dec 3, 2019 · Penalty $2,500

    Resolve
  • Class - 1

    Demolition work w/o required demolition/alt permit at time of inspection observed a full interior demolition in progress of a 4 sty bldg floors stripped down to subfloor walls striped down to brick walls & ceil

    Feb 28, 2019 · Penalty $5,000

    Resolve
  • Class - 1

    Demolition work w/o required demolition/alt permit at time of inspection observed. a full interior demolition of a 4 sty bldg all floors removed down to subflooring,wall removed down to brick walls,ceilings.

    Feb 28, 2019

    Resolve
  • Class - 3

    Work w/o permit. work noted: at 2 flr level removed part of partly wall to create opening in to 1105 lexington as work 100% complete. remedyobtain permit or restore to prior legal conditions.

    Jun 19, 2009 · Penalty $500

    Resolve
  • Non-hazardous

    51,49, picked up over 300 ppm carbon monoxide.

    Jan 13, 1999 · Penalty $400

    Resolve

Complaints

  • Heating

    Heat related

    Dec 16, 2011 · Apt BLDG

    Close
  • Heating

    Heat related

    Apr 20, 2011 · Apt BLDG

    Close
  • Heating

    Heat related

    Apr 20, 2011 · Apt BLDG

    Close
  • Heating

    Heat related

    Nov 28, 2009 · Apt 4F

    Close
  • Heating

    Heat related

    Nov 18, 2009 · Apt BLDG

    Close
  • Heating

    Heat related

    Nov 12, 2008 · Apt 4R

    Close
  • Heating

    Heat related

    Nov 12, 2008 · Apt 2R

    Close
  • Heating

    Heat related

    Oct 30, 2008 · Apt BLDG

    Close
  • Heating

    Heat related

    Oct 30, 2008 · Apt BLDG

    Close
  • Heating

    Heat related

    Oct 24, 2008 · Apt BLDG

    Close
Show 9 more ↓
  • Heating

    Heat related

    Oct 23, 2008 · Apt BLDG

    Close
  • Heating

    Heat related

    Oct 22, 2008 · Apt BLDG

    Close
  • Heating

    Heat related

    Oct 19, 2008 · Apt 3R

    Close
  • Heating

    Heat related

    Jan 31, 2008 · Apt BLDG

    Close
  • Heating

    Heat related

    Jan 29, 2008 · Apt 4F

    Close
  • Heating

    Heat related

    Dec 19, 2007 · Apt BLDG

    Close
  • Heating

    Heat related

    Dec 15, 2007 · Apt BLDG

    Close
  • Nonconst

    Vermin

    Jun 1, 2004 · Apt 3

    Close
  • Paint/plaster

    Wall

    Jun 1, 2004 · Apt 3

    Close

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Elevator apartment building (D6)
Year built
1910
Floors
4
Residential units
10
Building area
11,995 ft²
Lot area
2,334 ft²
Zoning
C1-8X
Community board
108
Council district
4
Block / lot
1412 / 21
Assessed value
$1,946,250
Landmark / historic district
No

HPD registration #136308, last renewed Sep 3, 2025.

Questions about 1105 Lexington Avenue

Who owns 1105 Lexington Avenue?

The owner of record in NYC Department of City Planning PLUTO data is Allied Xxxx LLC.

Does 1105 Lexington Avenue have violations?

Yes. NYC HPD has recorded 8 housing violations at this property.

Is 1105 Lexington Avenue rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was 1105 Lexington Avenue built?

City records list 1910 as the year it was built.

How many apartments are in 1105 Lexington Avenue?

It has 10 residential units and 11 units in total.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.