roofy

2 East 67 Street

Manhattan, NY 10065BBL 1-01381-0069Map

Owner of record: Fifth 67th INC

2 East 67 Street is an elevator apartment building built in 1928 in Manhattan, 10065. It has 15 residential units across 12 floors. The owner of record is Fifth 67th INC. HPD has recorded 1 housing violation here, most recently on October 24, 2016.

HPD violations
1
DOB violations
45
ECB violations
9
HPD complaints
0

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
Last violation Oct 24, 2016

Date of the most recent HPD inspection that found a problem.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 1

  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Oct 24, 2016

    Closed — Violation dismissed

DOB building violations · 45

  • Failure to submit eer none

    Failure to submit an eer per ad. code sec. 28-308.4 - multiple years (2023)

    Jun 23, 2024

    Dob violation - dismissed
  • Failure to submit eer none

    Failure to submit an eer per ad. code sec. 28-308.4 in 2022

    Apr 22, 2023

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 20, 2021

    Dob violation - resolved
  • Facade safety program facade required

    Fisp-facade safety program facade required

    Feb 21, 2019

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to priv res elevator - fail to correct defects on 2016 cat 1 insp/tst

    Jan 26, 2018

    Dob violation - dismissed
  • Private residential elevator elevatoroptional

    2016 vios issued to elevators in private res dwellings(1 or 2 family dwellings)

    Sep 15, 2017

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jul 21, 2017

    Dob violation - resolved
  • Elevator affirmation of correction elevatorrequired

    Vio issued to priv res elevator - fail to correct defects on 2015 cat 1 insp/tst

    Jan 3, 2017

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jul 31, 2014

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jul 31, 2014

    Dob violation - resolved
Show 35 more ↓
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jul 31, 2014

    Dob violation - resolved
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2012 cat 1 insp/tst

    May 30, 2014

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2012 cat 1 insp/tst

    May 30, 2014

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 5, 2012

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 5, 2012

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 5, 2012

    Dob violation - resolved
  • Private residential elevator elevatoroptional

    2011 vios issued to elevators in private res dwellings(1 or 2 family dwellings)

    Oct 1, 2012

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Nov 23, 2011

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Nov 23, 2011

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Nov 23, 2011

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 29, 2010

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 29, 2010

    Dob violation - resolved
  • Private residential elevator elevatoroptional

    Violation issued to elevators in private res dwellings (1 or 2 family dwellings)

    Nov 12, 2010

    Dob violation - dismissed
  • Elevator elevatoroptional

    Ll1081-local law 10/81 - elevator elevatoroptional

    Mar 21, 2008

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Aug 2, 2007

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Aug 2, 2007

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Aug 2, 2007

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jul 21, 2006

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jul 21, 2006

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jul 12, 2006

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Nov 6, 2001

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Nov 6, 2001

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Nov 6, 2001

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Nov 6, 2001

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Nov 6, 2001

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Nov 6, 2001

    Dob violation - resolved
  • Elevator elevatorrequired

    1p16962

    Dec 23, 1999

    Dob violation - resolved
  • Elevator elevatorrequired

    1p16850

    Jan 4, 1999

    Dob violation - resolved
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    May 4, 1998

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Sep 16, 1997

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 10, 1997

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Aug 29, 1995

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Mar 18, 1994

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Mar 18, 1993

    Dob violation - dismissed
  • Elevator elevatoroptional

    1

    Oct 12, 1989

    Dob violation - dismissed

ECB violations · 9

  • Class - 2

    Failure to maintain exterior building facade and appurtenances. *roof level, obseved cracked/spalled limestone panels on various locations at bulkhead on north and south elevations; and cracked window glass

    Oct 16, 2018 · Penalty $1,250

    Resolve
  • Class - 1

    59bb15,37t7,80b14-ps marcato elevator co. inc. license #412001 submitted a notorized affirmation of correction with intent of removing deficiencies found during a category 1 test. after an inspection conducted

    Dec 6, 2017 · Penalty $4,800

    Resolve
  • Class - 2

    59bb15,52b14,37t7,52u15/(59-bb-15)brake maintenance tag expired;(52-b-7)hoist ropes need shortning;(37-t-7)overhead and deflector sleave room not labeled;(52-u-15)hoist rope tag not filled out.

    Dec 6, 2017

    Resolve
  • Class - 2

    Sec. 3314.10.9. tiebacks shall be installed perpendicular to the face of the bldg or opposing angle tiebacks shall be installed. single tiebbacks installed at an angle are prohibited. noted: tieback for c-hooks

    Jun 9, 2010 · Penalty $400

    Resolve
  • Class - 1

    No record of daily inspection of suspended scaffold performed by authorized person on site. noted: no daily inspection log book at site at time of inspection suspended scaffold on top flr of the bldg.

    Jun 9, 2010 · Penalty $2,400

    Resolve
  • Hazardous

    40l11/74x11/74i04/ 40l11 inspection reveals missing pin to bearing collar cease use call dept of building before returning back to service 646*248-8738 -74x11 repair overhead lights 74i04 repair and patch wal

    Jul 24, 2002 · Penalty $500

    Resolve
  • Non-hazardous

    39h09/46b13/74o02/58o02/59o02/ 39h09-shemre groves worn regrove shemre 74002 properly clean car top

    Jul 24, 2002

    Resolve
  • Non-hazardous

    15b01/62d06/74x11/33o02/74i11/74b01/15b01-adjust 10 floor door spring tension to close -62d06 properly secure under car wires -74x11 repair over head light 33o02-remove grease on grooves and clear area of

    Jul 24, 2002

    Resolve
  • Non-hazardous

    73o02,50y11,74d06,39o09,37g12.(73o02)clean entry device.(50y11)repair oil leak.(74d06)properly secure timer on controller by mounting (39o09)traction sheave grooves filled with grease remove grease (37g12)prope

    Mar 3, 2000

    Resolve

Complaints

No HPD complaints in our records

Complaint data is still being backfilled from NYC Open Data.

Sales history

DatePriceTypeUnits
Jun 11, 2026Non-market transferCoops - elevator apartments—
Jun 11, 2026Non-market transferCoops - elevator apartments—

Building details

Building type
Elevator apartment building (D4)
Year built
1928
Floors
12
Residential units
15
Building area
93,515 ft²
Lot area
8,400 ft²
Zoning
R10
Community board
108
Council district
4
Block / lot
1381 / 69
Assessed value
$12,595,950
Landmark / historic district
Upper East Side Historic District

HPD registration #101794, last renewed Sep 9, 2025.

Questions about 2 East 67 Street

Who owns 2 East 67 Street?

The owner of record in NYC Department of City Planning PLUTO data is Fifth 67th INC.

Does 2 East 67 Street have violations?

Yes. NYC HPD has recorded 1 housing violations at this property.

Is 2 East 67 Street rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was 2 East 67 Street built?

City records list 1928 as the year it was built.

How many apartments are in 2 East 67 Street?

It has 15 residential units.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.