roofy

1005 1 Avenue

Manhattan, NY 10022BBL 1-01348-0023Map

Owner of record: X11 First Ave LLC

1005 1 Avenue is a school building built in 1907 in Manhattan, 10022. The owner of record is X11 First Ave LLC. HPD has no housing violations on record for this property.

HPD violations
0
DOB violations
146
ECB violations
46
HPD complaints
13

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
No HPD violations

HPD has not cited this building.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 0

No HPD violations on record

DOB building violations · 146

  • Construction other optional

    Concrete cylinders were not properly cured in accordance w/bc 1905.6.3 and astm c31. remedy:comply with code. eor to review non-conformance and provide s/s acceptance statement based on supplemental field test results

    Sep 18, 2026

    Dob violation - active
  • Low pressure boiler boiler required

    Violation issued-failure to file 2024 external low pressure inspection

    Nov 14, 2025

    Dob violation - active
  • Low pressure boiler boiler required

    Violation issued-failure to file 2023 external low pressure inspection

    Sep 23, 2024

    Dob violation - active
  • Construction other optional

    Dob summons issued for structure rendered non compliant due to motor vehicle impacting building at exposure #4 damaging 2 exterior marble panels.

    Jan 10, 2024

    Dob violation - active
  • Low pressure boiler boiler required

    Violation issued-failure to file 2020 external low pressure inspection

    Jun 30, 2023

    Dob violation - active
  • Low pressure boiler boiler required

    Violation issued-failure to file 2021 external low pressure inspection

    Jun 30, 2023

    Dob violation - active
  • Low pressure boiler boiler required

    Violation issued-failure to file 2018 external low pressure inspection

    Jun 20, 2023

    Dob violation - active
  • Low pressure boiler boiler required

    Violation issued-failure to file 2019 external low pressure inspection

    Jun 20, 2023

    Dob violation - active
  • Low pressure boiler boiler required

    Violation issued-failure to file 2022 external low pressure inspection

    Apr 25, 2023

    Dob violation - active
  • No report and / or late filing (facade) facade required

    Failed to file fisp cycle 9b technical report by 2/21/2023

    Feb 22, 2023

    Dob violation - dismissed
Show 40 more ↓
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    May 15, 2020

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    May 15, 2020

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    May 15, 2020

    Dob violation - resolved
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2017 inspection report

    Nov 8, 2019

    Dob violation - active
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tst

    Sep 6, 2019

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tst

    Sep 6, 2019

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tst

    Sep 6, 2019

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tst

    Sep 6, 2019

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tst

    Sep 6, 2019

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tst

    Sep 6, 2019

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tst

    Sep 6, 2019

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tst

    Sep 6, 2019

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tst

    Sep 6, 2019

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Apr 11, 2019

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Apr 11, 2019

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Apr 11, 2019

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Apr 11, 2019

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Apr 11, 2019

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Apr 11, 2019

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Apr 11, 2019

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Apr 11, 2019

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Apr 11, 2019

    Dob violation - resolved
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2016 inspection report

    Apr 6, 2018

    Dob violation - dismissed
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2015 inspection report

    Feb 24, 2017

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2015 cat 1 insp/tst

    Jan 3, 2017

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2015 cat 1 insp/tst

    Jan 3, 2017

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2015 cat 1 insp/tst

    Jan 3, 2017

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2015 cat 1 insp/tst

    Jan 3, 2017

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2015 cat 1 insp/tst

    Jan 3, 2017

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2015 cat 1 insp/tst

    Jan 3, 2017

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2015 cat 1 insp/tst

    Jan 3, 2017

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2015 cat 1 insp/tst

    Jan 3, 2017

    Dob violation - dismissed
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2014 inspection report

    Oct 1, 2015

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Apr 10, 2015

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Apr 10, 2015

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Apr 9, 2015

    Dob violation - resolved
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2013 inspection report

    Mar 3, 2015

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2012 cat 1 insp/tst

    May 30, 2014

    Dob violation - dismissed
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2012 inspection report

    May 15, 2014

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Apr 22, 2014

    Dob violation - resolved

ECB violations · 46

  • Class - 2

    During the inspection of alteration works for the 27-story building, observed at 22nd floor, 2 steel column connections contain multiple unused bolt holes. upon review of the approved shop drawings, these unuse

    Sep 17, 2026 · Penalty $1,250

    Active
  • Class - 2

    At time of inspection observed active structural work. observed workers modifying steel connection on site. upon requesting engineer approval or shop drawings allowing on site modifications none were provided.

    Aug 11, 2026 · Penalty $2,500

    Resolve
  • Class - 2

    At time of inspection observed on multiple level inadequate fire extinguishers. missing/broken inspection tags, no pressure, store on floor, missing monthly inspection signatures and expire tags. inadequate ext

    Aug 11, 2026 · Penalty $2,500

    Resolve
  • Class - 2

    At time of inspection observed unenclosed perimeter with inadequate guardrail cable system protection. zero cable has gaps between slab and cable up to approx. 3". condition contrary to bc 3308.5.3.1 which stat

    Aug 11, 2026 · Penalty $2,500

    Resolve
  • Class - 1

    The crane user barone steel inc.,failed to notify the department properly of the mobile crane's(liebherr ltm1300-6.3 cd5946 cn18926) arrival and departure from this site. they must make the notification 24/48 h

    Aug 6, 2026 · Penalty $10,000

    Active
  • Class - 2

    (1 rcny 3319-01(c)(5)the crane user(liebherr ltm 1300-6.3 cd5946 cn18926 ) barone steel inc. failed to notify the department properly of the arrival of the crane today. lift director adan vergara., properly not

    Jun 26, 2026

    Resolve
  • Class - 2

    (1 rcny 3319-01(c)(5)the crane user(cd5946 cn18926 ) barone steel inc. failed to notify the department properly of the arrival of the crane., properly notify the department

    Jun 23, 2026 · Penalty $5,000

    Active
  • Class - 1

    Responding to incident were a worker fell from a ladder on the 6 floor while ascending. inspection revealed that the ladder were in an unsafe condition with bent, broken, and twisted rear rungs that compromised

    Jun 17, 2026 · Penalty $5,000

    Resolve
  • Class - 1

    Note: at time of inspection, i observed 3 worker sheds within 30 feet from each other without the required permit, additionally, worker shed at expo #4 was not equipped with a smoke detector or sprinkler system

    Jun 17, 2026 · Penalty $5,000

    Resolve
  • Class - 1

    20 story alt2 facade active site.observed sidewalk shed in place at exp#1,2,4 permit#m01250783. white advertising signage attached to parapet wall stating,vanbarton group, for retail leasing inquries,. also not

    May 11, 2026 · Penalty $2,500

    Resolve
Show 36 more ↓
  • Class - 2

    20 story alt2 facade work active site. observed parapet clamps with netting on adjoining property used for window protection at exp#2,3. upon request to contractor for stamped engineer inspection/stability lett

    May 11, 2026 · Penalty $1,250

    Resolve
  • Class - 2

    20 story alt2 facade work active site. observed wood temporary enclosure approximately 16 ft in height by 60 ft in width attached/anchored to building on 3rd floor at exp#3. upon review of site safety plans. no

    May 11, 2026 · Penalty $625

    Resolve
  • Class - 2

    20 story alt2 facade work active site. observed supported scaffold in place permit#m01378984. approximately 104 ft in height upon review of plans, above truss system observed 1 set of extra scaffold frames, bri

    May 11, 2026 · Penalty $625

    Resolve
  • Class - 2

    20 story alt2 work active site.observed medium duty pipe scaffold on top of sidewalk shed approximately 130 ft on adjoining property for protection with netting in place at exp#3,4. request to contractor for se

    May 11, 2026 · Penalty $1,250

    Resolve
  • Class - 1

    At time of inspection, investigation of an incident revealed a worker used a ladder contrary to manufacturer specifications by facing away while performing work, resulting in a fall and injury, in violation of

    Apr 27, 2026 · Penalty $2,500

    Resolve
  • Class - 1

    Failure to operate hilti diamond drilling machine poses danger and caused incident. plumber was coring in concrete slab on 20th floor disconnected 6" jamming bit and used a hammer. manufacturer specifications w

    Feb 5, 2026 · Penalty $2,500

    Resolve
  • Class - 1

    Note: at time of inspection, upon review of department records it was noted that the permit holder failed to notify the department of an incident (as required 28-103.21.1) that occurred on 11/05/2025 where a

    Dec 8, 2025 · Penalty $5,000

    Resolve
  • Class - 1

    Responded to an incident in which a worker sustained a cut to the nose while grinding welds on the metal plates on the 21st floor. inspection revealed that the building is over 20 stories and 250 feet, upon req

    Nov 5, 2025 · Penalty $5,030

    Resolve
  • Class - 2

    Note: at time of inspection, i observed a 20 story building with ongoing construction operations, upon request for documentation of change in use from passenger to freight none was provided as required by 3303.

    Nov 5, 2025 · Penalty $2,530

    Resolve
  • Class - 1

    Responded to an incident in which a worker sustained a cut to the nose while grinding welds on the metal plates on the 21st floor. inspection revealed that the worker was not using adequate face protection such

    Nov 5, 2025 · Penalty $2,530

    Resolve
  • Class - 2

    Failure to submit an acceptable required cycle 9b report of critical examination documenting condition of exterior wall and appurtenances required by 28-302.4 for control #904718. remedy: submit acceptable requ

    Apr 11, 2024 · Penalty $1,250

    Active
  • Class - 2

    Failure to file annual certification that cooling tower 1000000889 has been inspected, tested and disinfected and that a maintenance plan has been developed and implemented by november 1, 2016. rem: file annual

    Jun 20, 2017 · Penalty $2,000

    Active
  • Class - 2

    Failure to file annual certification that cooling tower 1000000893 has been inspected, tested and disinfected and that a maintenance plan has been developed and implemented by november 1, 2016. rem: file annual

    Jun 20, 2017 · Penalty $2,000

    Active
  • Class - 1

    *cease use* 42l10,42al10,98m07,00m07,60m07.42:db relay aux contact & shunt.42a:wire on limit board on sfi terminal too much stress.98:missing cat 5 tag.99:missing cat 1 tag.69:code data tag missing.c/u accident

    Dec 3, 2012 · Penalty $1,000

    Resolve
  • Class - 2

    52k11.100x10.81m07.40d secure smoke hole by machine in m/r 67x repair ph. sysytem in car 100x repair access key sw

    Jun 23, 2009

    Resolve
  • Class - 2

    40d6.80b4.81m7.40d secure smoke hole in m/r 67x repair ph. system in car 100x repair access key sw. 80b shorten cwt ropes

    Jun 23, 2009

    Resolve
  • Non-hazardous

    Failure to submit a fifth round technical report:periodic inspection of exterior walls and appurtenances as required by local law 11 of 1998and the department of buildings rules and regulations remedy:file the

    Mar 19, 2004 · Penalty $350

    Resolve
  • Non-hazardous

    79u5/ 79-u-5 -perform & file 3 year pressure test

    May 9, 2003

    Resolve
  • Non-hazardous

    48,k,12. 48-k-12-excessive rouge a crown wear, replace.

    Apr 12, 2003

    Resolve
  • Non-hazardous

    48,b,15. 48-b-15- shorten hoist ropes

    Apr 12, 2003

    Resolve
  • Non-hazardous

    50b09/20l11. 50b09 remove rumbling noise from secondary sheave. 20l11 repair lobby hall button.

    Jul 16, 2002

    Resolve
  • Non-hazardous

    73x11/ repair elevator for proper d.o.b elevator respectors.

    Jul 16, 2002

    Resolve
  • Non-hazardous

    46h12/hoist cables 1,2,3, rusted and undersized replace

    Jun 19, 2002

    Resolve
  • Non-hazardous

    46l12,50h09,46-change hoist ropes #50 remove noise from traction sheive bearing.

    Mar 7, 2001

    Resolve
  • Non-hazardous

    43y11,43l12.43-properly seal pump unit.43-properly seal pump unit.43-replace defective oil line in pit.

    Mar 7, 2001

    Resolve
  • Non-hazardous

    46h15

    Sep 29, 2000

    Resolve
  • Non-hazardous

    11q3,18d6. 18- chain.

    Mar 21, 2000

    Resolve
  • Non-hazardous

    35d6,4m7,30p17,57p17,31q3. 35- smoke hole grating 4 keys 30key.

    Mar 21, 2000

    Resolve
  • Non-hazardous

    35d6,41q3,74s7,4m7,30p17,57p17. 35- smoke hole grating. 74- container as per code for ray 4 keys 30key.

    Mar 21, 2000

    Resolve
  • Non-hazardous

    35d6,30p17,57p17,75s7,4m7. 74- container as per code for rags. 30 key 4 keys.

    Mar 21, 2000

    Resolve
  • Hazardous

    35d06,57o02,04m07,30p17,60l11, (04)keys (30)key cease use until buffer& switch are working as per code- call 212 312-8738 before returning to service.

    Mar 21, 2000 · Penalty $500

    Resolve
  • Non-hazardous

    35d6,37q3,4m7,30p17. 4 keys 30 key.

    Mar 21, 2000

    Resolve
  • Non-hazardous

    35d637q3,47i12,57t7,4m7,30p17. 35- smoke hole grating 4 keys 30 key.

    Mar 21, 2000

    Resolve
  • Non-hazardous

    35d6,46o2,37q3,55x11,57o2,4m7,30p17. 35- smoke hole grating 4 keys 30 keys.

    Mar 21, 2000

    Resolve
  • Non-hazardous

    New building occupied without a valid certificate of occupancy. in that building 1011 1 st ave has been issued temp c/o #73127 d/d 8-19-75- but has not submitted applicationer been granted a final c of o. remed

    Apr 8, 1998

    Resolve
  • Non-hazardous

    46h.

    Jan 24, 1995

    Resolve

Complaints

  • Heat/hot water

    Apartment only

    Oct 7, 2026 · Apt 4D

    Open
  • Door/window

    Window frame

    Oct 7, 2026 · Apt 4D

    Open
  • General

    Janitor/super

    Oct 7, 2026 · Apt 4D

    Open
  • Heat/hot water

    Entire building

    Apr 28, 2023 · Apt BLDG

    Close
  • Unsanitary condition

    Pests

    Apr 28, 2023 · Apt 5D

    Close
  • Unsanitary condition

    Mold

    Apr 28, 2023 · Apt 5D

    Close
  • Flooring/stairs

    Floor

    Apr 28, 2023 · Apt 5D

    Close
  • Unsanitary condition

    Pests

    Apr 28, 2023 · Apt 5D

    Close
  • General

    Signage missing

    Jul 10, 2018 · Apt PARISH

    Close
  • Outside building

    Pavement

    Jul 10, 2018 · Apt PARISH

    Close
Show 3 more ↓
  • General

    Windows

    May 8, 2007 · Apt 4D

    Close
  • General

    Windows

    May 8, 2007 · Apt 4D

    Close
  • General

    Windows

    May 1, 2007 · Apt 4D

    Close

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
School building (W3)
Year built
1907
Floors
20
Residential units
—
Building area
398,214 ft²
Lot area
35,681 ft²
Zoning
R10
Community board
106
Council district
4
Block / lot
1348 / 23
Assessed value
$57,042,450
Landmark / historic district
No

Questions about 1005 1 Avenue

Who owns 1005 1 Avenue?

The owner of record in NYC Department of City Planning PLUTO data is X11 First Ave LLC.

Does 1005 1 Avenue have violations?

NYC HPD has no housing violations on record for this property.

Is 1005 1 Avenue rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was 1005 1 Avenue built?

City records list 1907 as the year it was built.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.