821 1 Avenue
Manhattan, NY 10017BBL 1-01338-0030Map
Owner of record: Republic Of Turkey
821 1 Avenue is an office building built in 2018 in Manhattan, 10017. It has 20 residential units across 35 floors. The owner of record is Republic Of Turkey. HPD has recorded 5 housing violations here, most recently on May 8, 2026. 5 of the 5 most recent violations are still open.
- HPD violations
- 5
- DOB violations
- 48
- ECB violations
- 32
- HPD complaints
- 7
What to know
No open immediately-hazardous violations among recent records.
Date of the most recent HPD inspection that found a problem.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 5
- ANon-hazardous
File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.
May 8, 2026
Open — Nov sent out - IInformation / order
And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.
Nov 17, 2025
Open — Info nov sent out - ANon-hazardous
File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.
Jun 13, 2025
Open — Nov sent out - IInformation / order
And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.
Nov 22, 2024
Open — Info nov sent out - ANon-hazardous
File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.
Apr 17, 2024
Open — Nov sent out
DOB building violations · 48
- Construction other optional
Failure to maintain exterior facade wall & appurtances. -refer to violation-. remedy: file unsafe fisp report. submit hands on report to [email protected]
Jun 22, 2026
Dob violation - active - Construction other optional
Structure rendered non-compliant. at time of inspection observed at 40th floor at exterior 1 window section of glass panel broke from unknown causes & pieces of glass fell to sidewalk & street.
Jun 17, 2026
Dob violation - active - Immediate emergency anythingoptional
Provide pedestrian protection sidewalk shed approximately 205' linear ft. at exposure#1 on (1st avenue) 40' linear ft. extending past and wrap around expo 4 at expo 4 on (east 46 street) 165' linear ft. to safeguard public and property
Jun 17, 2026
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued-failure to file 2022 external low pressure inspection
Apr 25, 2023
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued-failure to file 2022 external low pressure inspection
Apr 25, 2023
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued-failure to file 2022 external low pressure inspection
Apr 25, 2023
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued-failure to file 2022 external low pressure inspection
Apr 25, 2023
Dob violation - dismissed - Construction other optional
Due to failure to maintain exterior building facade with broken/ falling glass panel 07/20/2021. remedy: owner to immed retain nys lic prof/qewi to evaluate and inspect 100% of all facade exposures and glass panels, produce and provide report and proposal by 08/22/2021 to the facade unit at dept of bldgs. file and obtain permits
Jul 22, 2021
Dob violation - dismissed - Construction other optional
Failure to maintain exterior bldg facade and appurtenances. at time of inspection: north east elevation, exp 1 and 4 broken glass window on 17fl. glass had fallen and landed on 7fl set back at corner of 1st ave and east 46th st. remedy: maintain exterior bldg facade, provide safety measures, repair unsafe glass facade, make facade safe
Jul 22, 2021
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jun 26, 2019
Dob violation - dismissed
Show 38 more ↓
- Private residential elevator elevatoroptional
2017 vios issued to elevators in private res dwellings (1 or 2 family dwellings)
Apr 5, 2019
Dob violation - dismissed - Private residential elevator elevatoroptional
2017 vios issued to elevators in private res dwellings (1 or 2 family dwellings)
Apr 5, 2019
Dob violation - dismissed - Private residential elevator elevatoroptional
2017 vios issued to elevators in private res dwellings (1 or 2 family dwellings)
Apr 5, 2019
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Mar 6, 2019
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Mar 6, 2019
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Mar 6, 2019
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Mar 6, 2019
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Mar 6, 2019
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Mar 6, 2019
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Mar 6, 2019
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Dec 27, 2017
Dob violation - dismissed - Private residential elevator elevatoroptional
2016 vios issued to elevators in private res dwellings(1 or 2 family dwellings)
Sep 15, 2017
Dob violation - dismissed - Private residential elevator elevatoroptional
2016 vios issued to elevators in private res dwellings(1 or 2 family dwellings)
Sep 15, 2017
Dob violation - dismissed - Private residential elevator elevatoroptional
2016 vios issued to elevators in private res dwellings(1 or 2 family dwellings)
Sep 15, 2017
Dob violation - dismissed - Private residential elevator elevatoroptional
2015 vios issued to elevators in private res dwellings(1 or 2 family dwellings)
Dec 1, 2016
Dob violation - dismissed - Private residential elevator elevatoroptional
2015 vios issued to elevators in private res dwellings(1 or 2 family dwellings)
Dec 1, 2016
Dob violation - dismissed - Private residential elevator elevatoroptional
2015 vios issued to elevators in private res dwellings(1 or 2 family dwellings)
Dec 1, 2016
Dob violation - dismissed - Residential elevator periodic inspection/test elevatorrequired
Failure to perform category 5 inspection
Jun 1, 2016
Dob violation - dismissed - Residential elevator periodic inspection/test elevatorrequired
Failure to perform category 5 inspection
Jun 1, 2016
Dob violation - dismissed - Residential elevator periodic inspection/test elevatorrequired
Failure to perform category 5 inspection
Jun 1, 2016
Dob violation - dismissed - Private residential elevator elevatoroptional
2012 vios issued to elevators in private res dwellings(1 or 2 family dwellings)
Mar 31, 2014
Dob violation - dismissed - Private residential elevator elevatoroptional
2012 vios issued to elevators in private res dwellings(1 or 2 family dwellings)
Mar 31, 2014
Dob violation - dismissed - Private residential elevator elevatoroptional
2012 vios issued to elevators in private res dwellings(1 or 2 family dwellings)
Mar 31, 2014
Dob violation - dismissed - Private residential elevator elevatoroptional
2011 vios issued to elevators in private res dwellings(1 or 2 family dwellings)
Oct 1, 2012
Dob violation - dismissed - Private residential elevator elevatoroptional
2010 vios issued to elevators in private res dwellings (1 or 2 family dwellings)
Dec 13, 2011
Dob violation - dismissed - Private residential elevator elevatoroptional
Violation issued to elevators in private res dwellings (1 or 2 family dwellings)
Nov 12, 2010
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Nov 4, 2004
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Nov 4, 2004
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Nov 4, 2004
Dob violation - resolved - Elevator elevatoroptional
Ll1081-local law 10/81 - elevator elevatoroptional
Apr 21, 2004
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Jan 22, 2004
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jan 22, 2004
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jan 22, 2004
Dob violation - resolved - Elevator elevatoroptional
Ll1081-local law 10/81 - elevator elevatoroptional
Mar 21, 2003
Dob violation - dismissed - Elevator elevatoroptional
Ll1081-local law 10/81 - elevator elevatoroptional
Feb 19, 2002
Dob violation - dismissed - Elevator elevatoroptional
Ll1081-local law 10/81 - elevator elevatoroptional
Jan 13, 1997
Dob violation - active - Elevator elevatoroptional
Ll1081-local law 10/81 - elevator elevatoroptional
Jan 13, 1997
Dob violation - dismissed - Local law 5/73 none
Ll5-local law 5/73 none
Mar 31, 1989
Dob violation - dismissed
ECB violations · 32
- Class - 1
Unlawful acts: failure to comply to commissioner's order: note: dob violation #072221cllf01jf required the owner to provide a pe/ra report to the facade unit due to broken/falling glass panel at 17th floor of e
May 10, 2024
Resolve - Class - 2
Failure to maintain exterior facade and appurtenances. note: observed at exposure 4, east elevation a broken glass panel on the 16th floor. no loose material was observed. damaged panel is near northeast corner
May 10, 2024
Resolve - Class - 1
Unsafe storage of combustibles. notes: at time of inspection on an active jobsite i observed a flammable canister stored in a(shantie)on the4th fl. the tank was unsecured at the time & room was unlocked. canist
Mar 26, 2020 · Penalty $2,500
Resolve - Class - 1
Failure to institute & maintain safety equipment measures & temporary construction equipment. note: at the time of my inspection while responding to an incident where a piece of hardware fell off the constructi
Aug 8, 2019 · Penalty $10,000
Resolve - Class - 1
Failure to safe guard all persons and property as noted at time of my inspection active site 37 story building i observed no control zone was established at an opening edges 32nd,33rd,34th 35 floors at differen
Apr 4, 2019 · Penalty $10,000
Resolve - Class - 2
Work does not conform to pe approved drawings as noted at time of inspection active site 37 story building i observed platforms erected at elevator shafts,drawings approved by pe has different design work and p
Apr 4, 2019 · Penalty $625
Resolve - Class - 1
Failure to maintain adequate housekeeping as noted at time of inspection active site 37 story bldg i observed debris ot the following at construction site brick,wooden objects and plywood sheets,cartoon & plast
Apr 4, 2019 · Penalty $2,500
Resolve - Class - 1
Unsafe storage of materials during construction as noted at time of inspection,active site 37 story building i observed different materials stored within 10ft from unenclosed perimeters which results in unsafe
Apr 4, 2019 · Penalty $2,500
Resolve - Class - 2
Bc1704.4/failure to provide a continuos special inspection during grouting operations.as noted:at time of inspection active site.37 story building i observed grouting operations for cmu walls at 32 flr.no mason
Apr 4, 2019 · Penalty $620
Resolve - Class - 1
Bc3308.1/failure to provide safety netting requirement.as noted at time of inspection active site 37 story building i observed(floors 30-35)vertical netting is not maintained and has alot of holes and not secur
Apr 4, 2019 · Penalty $2,500
Resolve
Show 22 more ↓
- Class - 1
3301.2;failure to maintain safe operations.note:at the time of my inspection of an active jobsite responding to complaint #1504322 where it was reported that a worker fell in a hole that was not covered when th
Mar 19, 2019 · Penalty $10,000
Resolve - Class - 1
Bc3301.4 inspection. noted: at the time of inspection of an active jobsite, i observed a fall protection system used perimeter on exp1 at 2rd and 4th floor. upon request for records of daily inspection for
Mar 19, 2019 · Penalty $625
Resolve - Class - 1
3301.2;fail to institute and maintain safe operations.at the time of my inspection of an actve jobsite answering an incident (complaint #1502241)where a flagman were backing up a concrete truck that did not sto
Feb 20, 2019 · Penalty $2,530
Resolve - Class - 1
Failure to protect public or property. during concrete pouring ops,the(chute guard)for the concrete bucket which was being held in place by the overhead crane was missed out of place,not in the right location,
Dec 19, 2018
Resolve - Class - 1
Housekeeping. observed active construction site 35 sty nb currently at17 stys,housekeeping inadequate consisting of construction materials,debris,extension cords,laying on floors creating a trip & fall hazard
Dec 19, 2018 · Penalty $2,500
Resolve - Class - 1
Sec. 3301.2 failure to maintain control access zones observed active construction site 38 sty nb currently at 17 stys,observed,control access zone was not maintained/enfoced at various locations through site,
Dec 19, 2018 · Penalty $625
Resolve - Class - 2
Work does not conform to approved construction documents upon review of pe design drawing for wood plat forms in the elevator shafts or stair shafts at bldg west side exp#3,i observed that the wood platforms in
Dec 19, 2018 · Penalty $625
Resolve - Class - 1
Sec. 3309.1 protection of adjacent property observed at exp#3 protection of adj property wss inadequate. stop all work at exp# perimeter above 10th fl. remedy: provide & maintain adequate overhead/roof protecti
Dec 19, 2018
Resolve - Class - 1
Sec. 3303.4.5.2 storage near unenclosed perimeters. note: at the time of my inspection of a 35 sty bldg at 17th fl level construction work in progress. i observed reshores formwork & material metal containers
Dec 13, 2018 · Penalty $2,500
Resolve - Class - 1
Training. note: at the time of my inspection of a 35 sty bldg at 17th fl level construction work in progress. i observed 2 workers performing masonry operation on 3rd fl level perimeter at exp#2 on supported
Dec 13, 2018 · Penalty $625
Resolve - Class - 1
Work does not conform to approved construction documents & or approvedamendments. note: at the time of my inspection of a 35 sty bldg at 17th fl level construction work in progress. i observed safety concrete
Dec 13, 2018 · Penalty $625
Resolve - Class - 2
Failure to institute & maintain safety equipment measures & temporary construction. note: at the time of my inspection of a 35 sty bldg at 17th fl level construction work in progress. i observed that there were
Dec 13, 2018
Resolve - Class - 1
Sec. 3307.6.5.7 installation inspection. note: at the time of my inspection of a 35 sty bldg at 17th fl level construction work in progress.i observed a sidewalk shed erected & being use for storage of office
Dec 13, 2018
Resolve - Class - 1
Failure to safeguard.at the time of inspection of a 35 story new building under construction.active jobsite.as per site safety managers report a metal wing nut fell from forwork from(unknown floor)and brok adja
Nov 26, 2018 · Penalty $10,000
Resolve - Class - 1
Bc3310.10/inadequate safety orientation and training.at the time of inspection as per site safety managers report a metal wing nut fell fromformwork(from unknown flr)and brok adjacent propertys(at 809 1st ave)w
Nov 26, 2018
Resolve - Class - 1
Bc3309.14/protect adjoining property.window protection at the time of isnpetion of a 35 story neew building under construction.active jobsite as per site safet manages report a metal wing nut fell from formwork
Nov 26, 2018
Resolve - Class - 2
Work does not conform to approved construction documents and/or approved amendments. as noted: at time of inspection @ an active construction site. observed at 1st floor level at exp #4 steel column has been er
Aug 22, 2018 · Penalty $1,280
Resolve - Class - 1
Failure to instiute/maintain safety equipment measures or temporary construction missing guardrails and toeboards. at time of inspection i observed active construction site with contractor was doing excava
Jan 9, 2018 · Penalty $1,200
Resolve - Class - 2
Failure to provide approved/accepted plans at job sie at time of inspection. at time of inspection i observed active construction site. during inspection i ask super for his demolition plans and demolition plac
Jan 9, 2018
Resolve - Class - 2
Failure to maintain adequate houskeeping per section requirement. at itime of inspection i observed active construction site with contrctual work doing excavation work jobsitehad debris, rebar boxes around exc
Jan 9, 2018
Resolve - Class - 1
3318.3-95m7)cease use 97m7 failure to provide notification of rise of the cathead when the travel of the hoist is increased or decreased as per ansi a10.4 section 26.
Jul 18, 2017 · Penalty $1,600
Resolve - Class - 2
Failure to file annual certification that cooling tower 1000004780 hasbeen inspected,tested,and disinfected and that a maintenance plan has been developed and implemented by november,1,2016.rem:file annual cert
Jun 22, 2017 · Penalty $1,000
Resolve
Complaints
- General
Signage missing
Sep 2, 2021 · Apt BLDG
Close - Electric
Power outage
Sep 2, 2021 · Apt BLDG
Close - Heating
Heat related
Nov 19, 2011 · Apt 1
Close - Heating
Heat related
Nov 19, 2011 · Apt 2FL
Close - Heating
Heat related
Nov 13, 2011 · Apt 1
Close - Heating
Heat related
Nov 5, 2011 · Apt 1
Close - Heating
Heat related
Dec 5, 2007 · Apt 4F
Close
Sales history
No recorded sales in our data
Building details
- Building type
- Office building (O9)
- Year built
- 2018
- Floors
- 35
- Residential units
- 20
- Building area
- 189,840 ft²
- Lot area
- 12,067 ft²
- Zoning
- C5-2
- Community board
- 106
- Council district
- 4
- Block / lot
- 1338 / 30
- Assessed value
- $42,741,000
- Landmark / historic district
- No
Questions about 821 1 Avenue
Who owns 821 1 Avenue?
The owner of record in NYC Department of City Planning PLUTO data is Republic Of Turkey.
Does 821 1 Avenue have violations?
Yes. NYC HPD has recorded 5 housing violations at this property.
Is 821 1 Avenue rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 821 1 Avenue built?
City records list 2018 as the year it was built.
How many apartments are in 821 1 Avenue?
It has 20 residential units and 21 units in total.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.