roofy

805 3 Avenue

Manhattan, NY 10022BBL 1-01323-0047Map

Owner of record: 805 Third New York LLC

805 3 Avenue is an office building built in 1980 in Manhattan, 10022. The owner of record is 805 Third New York LLC. HPD has no housing violations on record for this property.

HPD violations
0
DOB violations
256
ECB violations
60
HPD complaints
11

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
No HPD violations

HPD has not cited this building.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 0

No HPD violations on record

DOB building violations · 256

  • Low pressure boiler boiler required

    Violation issued-failure to file 2024 external low pressure inspection

    Nov 14, 2025

    Dob violation - active
  • Low pressure boiler boiler required

    Violation issued-failure to file 2023 external low pressure inspection

    Sep 23, 2024

    Dob violation - active
  • Failure to submit eer none

    Failure to submit an eer per ad. code sec. 28-308.4 in 2023

    Jun 23, 2024

    Dob violation - active
  • Low pressure boiler boiler required

    Violation issued-failure to file 2020 external low pressure inspection

    Jun 30, 2023

    Dob violation - active
  • Low pressure boiler boiler required

    Violation issued-failure to file 2021 external low pressure inspection

    Jun 30, 2023

    Dob violation - active
  • Low pressure boiler boiler required

    Violation issued-failure to file 2018 external low pressure inspection

    Jun 20, 2023

    Dob violation - active
  • Low pressure boiler boiler required

    Violation issued-failure to file 2019 external low pressure inspection

    Jun 20, 2023

    Dob violation - active
  • Low pressure boiler boiler required

    Violation issued-failure to file 2022 external low pressure inspection

    Apr 25, 2023

    Dob violation - active
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Feb 3, 2021

    Dob violation - active
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Nov 25, 2020

    Dob violation - dismissed
Show 40 more ↓
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Sep 2, 2020

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Apr 30, 2020

    Dob violation - active
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Apr 30, 2020

    Dob violation - active
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Apr 30, 2020

    Dob violation - active
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Apr 30, 2020

    Dob violation - active
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Apr 30, 2020

    Dob violation - active
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Apr 30, 2020

    Dob violation - active
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Apr 30, 2020

    Dob violation - active
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Apr 30, 2020

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Apr 30, 2020

    Dob violation - active
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Apr 30, 2020

    Dob violation - active
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Apr 30, 2020

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Apr 30, 2020

    Dob violation - active
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Apr 30, 2020

    Dob violation - active
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Feb 5, 2020

    Dob violation - dismissed
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2017 inspection report

    Jan 17, 2020

    Dob violation - active
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tst

    Sep 6, 2019

    Dob violation - active
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tst

    Sep 6, 2019

    Dob violation - active
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tst

    Sep 6, 2019

    Dob violation - active
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tst

    Sep 6, 2019

    Dob violation - active
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tst

    Sep 6, 2019

    Dob violation - active
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tst

    Sep 6, 2019

    Dob violation - active
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tst

    Sep 6, 2019

    Dob violation - active
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tst

    Sep 6, 2019

    Dob violation - active
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tst

    Sep 6, 2019

    Dob violation - active
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tst

    Sep 6, 2019

    Dob violation - active
  • Sprinkler none

    Failed to file final sprinkler report by july 1, 2019

    Sep 3, 2019

    Dob violation - active
  • Sprinkler none

    Failed to file final sprinkler report by july 1, 2019

    Sep 3, 2019

    Dob violation - active
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Apr 3, 2019

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Apr 3, 2019

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Apr 2, 2019

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Apr 2, 2019

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Apr 2, 2019

    Dob violation - resolved
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst

    Jan 26, 2018

    Dob violation - active
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst

    Jan 26, 2018

    Dob violation - active
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst

    Jan 26, 2018

    Dob violation - active
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst

    Jan 26, 2018

    Dob violation - active
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst

    Jan 26, 2018

    Dob violation - active
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Nov 15, 2017

    Dob violation - dismissed
  • Elevator annual inspection / test elevatorrequired

    Violation issued to elevator-failure to file category 1 2016 inspection/test

    Sep 15, 2017

    Dob violation - active

ECB violations · 60

  • Class - 2

    Class 2 rts:: failure to maintain building in code compliant manner. upon inspection, the device is found to be out of service. remedy: restore to service and contact the dob elevator division at elevatorir@bui

    Jul 11, 2025 · Penalty $625

    Active
  • Class - 2

    A.c.27-929.1, failure to complete the installation of a full system ofautomatic sprinklers and file a final sprinkler report prepared by a registered design professional in an office building 100 feet or more i

    Jun 17, 2024 · Penalty $10,000

    Active
  • Class - 2

    A.c.27-929.1,failure to complete installation of full system of automatic sprinklers & file final sprinkler report prepared by registered design professional in office building 100 feet or more in height in exi

    Jun 17, 2024 · Penalty $10,000

    Active
  • Class - 2

    At time of inspection on 8/21/23 at 645-7 pm the pops site is closed and unavailable to the public as required by dcp report., comply with zr

    Aug 21, 2023 · Penalty $5,000

    Resolve
  • Class - 3

    Failure to maintain building in a code-compliant manner. at the time of inspection, i observed 2 of the 6 doors (not including revolving doors) are not working properly due to defective hardware and are closed.

    May 15, 2023 · Penalty $500

    Active
  • Class - 2

    27-929.1 failure to complete the installation of a full system of automatic sprinklers and file a final sprinkler report prepared by a registered design professional in an office building 100 feet or more in he

    Feb 28, 2023 · Penalty $6,250

    Active
  • Class - 2

    Ac 27-929.1, failure to complete the installation of a full system of automatic sprinklers and file a final sprinkler report prepared by a registered design professional in an office building 100ft or more in h

    Feb 28, 2023 · Penalty $10,000

    Active
  • Class - 2

    27-929.1 failure to complete installation of full system of automatic sprinklers and file final sprinkler report prepared by registered design professional in office building 100 feet or more in height in exist

    Nov 1, 2021 · Penalty $3,125

    Active
  • Class - 2

    Sec. 27-929.1 failure to complete the installation of a full system ofautomatic sprinklers & file a final sprinkler report prepared by a registered design professional in an office bldg 100 feet or more in heig

    Mar 30, 2021 · Penalty $3,125

    Active
  • Class - 2

    27-929.1 failure to complete the installation of a full system of automatic sprinklers and file a final sprinkler report prepared by a registered design professional in an office building 100ft or more in heigh

    Mar 30, 2021 · Penalty $10,000

    Active
Show 40 more ↓
  • Class - 1

    97x17: 97-x-17 this elevator is out of service repair device and restore to service immediately and contact nycdob by 212 393 2435

    Nov 4, 2020 · Penalty $1,250

    Active
  • Class - 1

    No door lock monitoring installed in this controller as mandated by 3.10.12 of k3 2014 nycbc. this is a controller feature which ensures passengers safety. remedy; file application, install dlm and perform and

    Aug 26, 2020 · Penalty $1,250

    Resolve
  • Class - 1

    Bc 3307.3.1 failure to provide sidewalk shed where required.at time of inspection i observed no sws over a japanese resturant and about 20feet from the restaurant as well.sidewalk sheds shall be provided as req

    May 29, 2020 · Penalty $10,000

    Resolve
  • Class - 2

    27-929.1 failure to complete the installation of a full system of automatic sprinklers and file a final sprinkler report prepared by a registered design professional by july 1,2019,in an office building 100 fee

    Mar 30, 2020 · Penalty $10,000

    Active
  • Class - 2

    Failure to submit a required cycle 8b report of critical examination documenting condition of exterior walls & appurtenances required by 28-302.4 for control#804599. remedy: submit acceptable required technica

    Feb 13, 2020 · Penalty $1,250

    Active
  • Class - 2

    Pedestrian protection does not meet code specification #bc 3307.6.5.3.failure to maintain sidewalk shed. note:at the time of inspection observed a heavy duty sws at exposure 1 and 4. pedestrians walking under t

    Nov 19, 2019

    Resolve
  • Class - 2

    Ac279291-failure to complete the installation of a full system of automatic sprinklers and file a final sprinkler report prepared by a registered design professional by july,1,2019,in an office building 100 fee

    Nov 15, 2019 · Penalty $6,250

    Active
  • Class - 2

    Ac279291-failure to complete the installation of a full system of automatic sprinklers and file a final sprinkler report prepared by a registered design professional by july 1,2019,in an office building 100 fee

    Nov 15, 2019 · Penalty $1,250

    Active
  • Class - 1

    97/x/17 restore to service for proper inspection by dob.

    Nov 14, 2019 · Penalty $1,250

    Resolve
  • Class - 2

    Sidewalk shed parapet panel.noted:@time of insp,observed sidewalk shederected @exp one & two.i also observed that there were no parapet panel information posted on the sidewalk shed parapet as required.required

    Apr 9, 2019 · Penalty $625

    Resolve
  • Class - 2

    Temporary construction equipment on site. expired permit. note at timeof inspection i observed sidewalk shed on site w/o an active permit onfile. permit for sidewalk shed on site w/o an active permit.rmdy:renew

    Jan 17, 2019

    Resolve
  • Class - 2

    Bc3307.6.4.9/failure to install sidewalk shed so not to obstruct access to bus stop.noted:at bus stops located on 50th street and 3rd ave,sidewalk shed crossbars obstructing clear passage and access to bus stop

    Aug 29, 2018 · Penalty $1,250

    Active
  • Class - 2

    Temporary construction equipment on site-expired permit.noted;sidwalk shed running along 3rd ave and 5th street continues to stand erected under expired permit#140594435-01eqsh.permit expired 1/18/18.rem:renew

    Aug 29, 2018 · Penalty $1,250

    Resolve
  • Class - 2

    3307.6.4.9 sidewalk shed not to code specification. note: at time of inspection, i observed sidewalk shed on site. cross braces from sidewalk shed interfere with access to bus stop. persons can not reasonably e

    Aug 10, 2018 · Penalty $1,250

    Active
  • Class - 2

    Pedestrian protection does not meet code specification. note: at time of inspection, i observed sidewalk shed on site without extensions over adjoining property. sidewalk shed shall extend past property lines

    Aug 10, 2018

    Resolve
  • Class - 2

    Temporary construction equipment on site: expired permit. note: at time of inspection, i observed sidewalk shed on site without an active permit on file. permit for sidewalk shed on site without an active permi

    Aug 10, 2018 · Penalty $1,250

    Resolve
  • Class - 2

    Pedestrian protection does not meet code specification. note: at time of inspection, i observed sidewalk shed on site with the following objections: -damaged mudsills. -exposed bolts. -inoperable light bulbs. -

    Aug 10, 2018 · Penalty $2,400

    Active
  • Class - 1

    Unlawful acts. failure to comply with an order the commissioner. in april 10, 2012, electrical violation was issued to the respondent. the respondent failed to comply with administrative code #28-201.1 (ecb) #m

    Jun 25, 2018 · Penalty $6,250

    Resolve
  • Class - 1

    Unlawful acts.failure to comply with an order of the commissioner.in august 9 2017 -january 12 2018 two violations was issue to the respondent.the respondent failed to comply with (nyc electrical code #110.2(a)

    Apr 10, 2018 · Penalty $2,500

    Resolve
  • Class - 2

    Violation of discretionary zoning conditions on privately owned public space.noted:at time of inspecton public plaza missing reqd amenities;restrooms 2 on concourse level,2restrms provided & locked(no access),p

    Jan 26, 2018 · Penalty $4,000

    Active
  • Class - 1

    Unlawful acts.failure to comply with an order of the commissioner.in august 09 2017,october 02 2017.two violations was issue to the respondent.the respondent failed to comply with (nyc)#28.201.1,110.2(a),(ecb's

    Jan 12, 2018 · Penalty $2,400

    Resolve
  • Class - 1

    Unlawful acts. failure to comply w/an order of the commissioner. in 8-9-17 a electrical violation was issue to the respondent. the respodent failed to comply w/nyc electrical code#110.2(a)(ecb)#35227570x.

    Oct 2, 2017

    Resolve
  • Class - 1

    Unapproved,unsafe,unsuitable electrical equipment,apparatus,materials,devices,appliances or wiring in use.15fl electrical closet:defective open temporary wiring in use throughout the ceiling,defective,

    Aug 9, 2017 · Penalty $1,600

    Resolve
  • Class - 2

    Failure to comply w/commissioner's order contained in summons/violation #35219137p issued on 12/24/16 and to file a certificate of correction pursuant to 28-201.1 and 14cny 102-01. rmdy: comply w/commissioner's

    Feb 8, 2017 · Penalty $800

    Resolve
  • Class - 2

    Failure to maintain bldg walls appurtenances.noted:at time inspection(a)at expo 1(3ave)(i)defective/seperated metal molding at top of 29/f window at middle section(ii)dislodged vertical molding/mullion at a/f

    Dec 27, 2016 · Penalty $500

    Resolve
  • Class - 1

    Failure to maintain bldg wall(s) or appurtenances.noted:2nd flr section of curtain wall glass approx 6'x10' has fallen to ground.said section of class is part of a restaurant d.b.a "gyu-kaka". additional inspec

    Dec 24, 2016 · Penalty $5,000

    Resolve
  • Class - 1

    Electrical work w/out a permit.the entire motor rms 4 & 5 floor:branchcircuit wiring,control wiring, 16th motors,controller.rem:obtain permit."not on file" observe @3:30pm weg nemo premium.model #100180t3e404ts

    Oct 8, 2015 · Penalty $400

    Active
  • Class - 1

    Approved/unsafe/unsuitable electrical equipment,apparatus,materials,devices,appliances or wiring in use.motor rms 4 & 5 floors:motors model #100180t3e404ts made in brazil,277,480 volts (their) one not approved

    Oct 8, 2015 · Penalty $300

    Active
  • Class - 2

    Failure to maintain building walls and appurtenances. noted at exp4 (3rd avenue) spalled bricks were found at various flrs such as by 10f window a tnorth section and between 19f and 18f at south section etc.

    Sep 18, 2015

    Resolve
  • Class - 2

    52k11,59e01. 52k- replace rusted and undersized hoist ropes. 59e- adjust, clean and lubricate broke plunger.

    Dec 4, 2012 · Penalty $250

    Resolve
  • Class - 2

    W/o a permit.const/electrical/plumbing.work noted:men working on 30th fl installing metal studs sheetrock.no permit on file for this work&nodrawing.demo on fl is done.men were setting up layout on fl studying,r

    Aug 24, 2011 · Penalty $800

    Resolve
  • Class - 3

    99b07,11m07,58h10. 99b07-perform annual test. 11m07-provide city id number 1p32040 on car station panel. 58h10- defective machine bearing repair.

    Jul 11, 2011 · Penalty $200

    Resolve
  • Class - 3

    99bb07 60q03. 99bb07-perform 1 year test. 60q03-guard motor room lighting.

    Apr 25, 2011 · Penalty $200

    Resolve
  • Class - 2

    12-x-10/12-q-03/12-repair all car lighting and guard

    Feb 24, 2011

    Resolve
  • Class - 3

    60b07,60q03,12d06,12q03,34b07.(60b07)provide proper lighting in motor room by controller.(60q03)properly guard lighting in motor room.(12d6)properly secure lighting in elevator.(12q03)properly guard lighting in

    Feb 2, 2011

    Resolve
  • Class - 3

    Work w/o a permit: illegal work noted: at 3rd flr roof of 2 sty rear bldg. hot water heater exhaust breeched exhaust pipe not to nyc code fastened to bldg inadequately. heater & pipe originate from eating and

    Jul 27, 2010 · Penalty $200

    Resolve
  • Non-hazardous

    83x10. 83-return elevator to service.

    Apr 26, 2007 · Penalty $180

    Resolve
  • Non-hazardous

    83x10. 83- return elevator to service.

    Apr 26, 2007 · Penalty $180

    Resolve
  • Non-hazardous

    83x10. 83- return elevator to service.

    Apr 26, 2007 · Penalty $350

    Resolve
  • Non-hazardous

    Cease use:80i11/cease use:84b9/.cease use items-80-severly damaged stop treads on 2 dozen steps-replace.84-scaffold over unit top has reduced overhead clearance to less than 7ft.remove scaffold to operate unit.

    Mar 13, 2007 · Penalty $500

    Resolve

Complaints

  • Heat/hot water

    Entire building

    Feb 9, 2026 · Apt BLDG

    Close
  • Heat/hot water

    Entire building

    Jan 15, 2025 · Apt BLDG

    Close
  • Heat/hot water

    Entire building

    Dec 20, 2024 · Apt BLDG

    Close
  • Heat/hot water

    Entire building

    Dec 20, 2024 · Apt BLDG

    Close
  • Heat/hot water

    Entire building

    Dec 14, 2024 · Apt BLDG

    Close
  • Heat/hot water

    Entire building

    Dec 13, 2024 · Apt BLDG

    Close
  • Heat/hot water

    Entire building

    Jan 22, 2024 · Apt BLDG

    Close
  • Heat/hot water

    Entire building

    Feb 15, 2022 · Apt BLDG

    Close
  • Heat/hot water

    Entire building

    Jan 23, 2022 · Apt BLDG

    Close
  • Heat/hot water

    Apartment only

    Mar 10, 2017 · Apt 14J

    Close
Show 1 more ↓
  • Heat/hot water

    Entire building

    Mar 10, 2017 · Apt BLDG

    Close

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Office building (O4)
Year built
1980
Floors
29
Residential units
—
Building area
597,553 ft²
Lot area
24,975 ft²
Zoning
C6-6
Community board
106
Council district
4
Block / lot
1323 / 47
Assessed value
$71,908,200
Landmark / historic district
No

Questions about 805 3 Avenue

Who owns 805 3 Avenue?

The owner of record in NYC Department of City Planning PLUTO data is 805 Third New York LLC.

Does 805 3 Avenue have violations?

NYC HPD has no housing violations on record for this property.

Is 805 3 Avenue rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was 805 3 Avenue built?

City records list 1980 as the year it was built.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.