150 East 45 Street
Manhattan, NY 10017BBL 1-01299-0041Map
Owner of record: Rsh Properties LLC
150 East 45 Street is a store building built in 1950 in Manhattan, 10017. The owner of record is Rsh Properties LLC. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 46
- ECB violations
- 14
- HPD complaints
- 0
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 46
- Low pressure boiler boiler required
Violation issued-failure to file 2023 external low pressure inspection
Sep 23, 2024
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued-failure to file 2023 external low pressure inspection
Sep 23, 2024
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued-failure to file 2020 external low pressure inspection
Jun 30, 2023
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued-failure to file 2020 external low pressure inspection
Jun 30, 2023
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued-failure to file 2022 external low pressure inspection
Apr 25, 2023
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued-failure to file 2022 external low pressure inspection
Apr 25, 2023
Dob violation - dismissed - Hazardous condition (facade) facade required
Cycle 9a unsafe report filed
Feb 18, 2022
Dob violation - dismissed - Failure to correct swarmp conditions (facade) facade required
Cycle 9a failure to correct swarmp conditions
Feb 18, 2022
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Mar 24, 2020
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Mar 24, 2020
Dob violation - resolved
Show 36 more ↓
- Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Aug 2, 2019
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
May 2, 2019
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Mar 22, 2019
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Mar 19, 2019
Dob violation - resolved - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst
Jan 26, 2018
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst
Jan 26, 2018
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Mar 17, 2016
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Mar 17, 2016
Dob violation - resolved - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2012 inspection/test
Mar 31, 2014
Dob violation - dismissed - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2012 inspection/test
Mar 31, 2014
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 21, 2014
Dob violation - resolved - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jan 15, 2014
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Jan 19, 2013
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jan 19, 2013
Dob violation - resolved - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2011 inspection/test
Oct 1, 2012
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2010 cat 1 insp/tst
Aug 15, 2012
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Jul 6, 2011
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jul 6, 2011
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Sep 9, 2010
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Sep 9, 2010
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
May 16, 2008
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
May 16, 2008
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jul 2, 2007
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jul 2, 2007
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 12, 2006
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Oct 23, 2003
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Oct 23, 2003
Dob violation - resolved - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 27, 2001
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 27, 2001
Dob violation - dismissed - Elevator elevatorrequired
1p27787
Feb 28, 2000
Dob violation - resolved - Elevator elevatorrequired
1p27788
Feb 28, 2000
Dob violation - resolved - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Mar 16, 1999
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Mar 16, 1999
Dob violation - dismissed - Elevator elevatoroptional
2
Jun 28, 1993
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Mar 18, 1993
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Mar 18, 1993
Dob violation - dismissed
ECB violations · 14
- Class - 2
Removal of public protection from unsafe facade w/o approval from dept.at time of inspection observed no public protection along exterior facade that filed unsafe.remedy:comply with rule.
Sep 5, 2023 · Penalty $1,280
Resolve - Class - 2
Vf. communication defective repair. electronic edge cover missing provide. provide permanent car light.
May 15, 2023 · Penalty $625
Resolve - Class - 2
Vf .hoist machine brake maintenance tag expired provide. communication defective repair. provide permanent car top light , provide permanent car light. provide electronic edge cover. pit light defective repair.
May 15, 2023 · Penalty $625
Resolve - Class - 1
3301.1.1 responsibility for safety atoi of active site i observed workperformed on baker scf on top of makeshift platform (wood) platform onopen large hole aprx12' above grnd no manufacturer specs &or dd for ma
Aug 3, 2022 · Penalty $2,500
Resolve - Class - 1
Work does not conform to approved plans-needle beams. upon review of approved plans needles beams at exposure 2 on 3rd floor are to be 8 ft long however they are 9ft. *stop all work on supported scaffold on nee
Jun 23, 2022 · Penalty $625
Resolve - Class - 1
Work does not conform to approved plans- supported scaffold exposure 4. upon review of approved plans provided it states only 5 working platforms are to be provided,however 7 working platforms are in place *sto
Jun 23, 2022 · Penalty $625
Resolve - Class - 1
Work does not conform to approved plans-sidewalk shed exposure#1- upon review of provided approved drawings it shows that sidewalk shed is missing double cross bracing sections and missing a steel pipe over dri
Jun 23, 2022 · Penalty $625
Resolve - Class - 1
97b10 - device #1p27787 cease use due to intrapment and intermitting problems with shutting down during run to landing floor remedy. repairdevice call dob 212-566-5542 to have inspection before return device
Jan 22, 2013 · Penalty $1,000
Resolve - Non-hazardous
B4a,16,19b,50a,c,32a,34a,36,50b.50a-flue connections installed incorrectly.50b-fresh air required fire damper.50c-replace missing( ) cords.
Jul 27, 2007 · Penalty $180
Resolve - Non-hazardous
B4a/ 32a/ 19b/ 50a/ 50c/ 16/ 34a/ 36/ 50b/ 50a flue connections installed incorrectly 50b fresh air required fire damper 50c replace missingcontrol covers
Jul 27, 2007 · Penalty $180
Resolve
Show 4 more ↓
- Non-hazardous
50k12,50y14,50o02, replace main machine. 50y seal main machine. 50o- clean main machine.
Jul 24, 1998 · Penalty $180
Resolve - Non-hazardous
50y14,46k12,50o02
Jul 24, 1998 · Penalty $180
Resolve - Non-hazardous
37d.37-fireman service relays.
Mar 13, 1996
Resolve - Non-hazardous
37d.37-fireman service relays.
Mar 13, 1996
Resolve
Complaints
No HPD complaints in our records
Sales history
No recorded sales in our data
Building details
- Building type
- Store building (K7)
- Year built
- 1950
- Floors
- 7
- Residential units
- —
- Building area
- 33,515 ft²
- Lot area
- 7,535 ft²
- Zoning
- C5-2.5
- Community board
- 106
- Council district
- 4
- Block / lot
- 1299 / 41
- Assessed value
- $6,111,900
- Landmark / historic district
- No
Questions about 150 East 45 Street
Who owns 150 East 45 Street?
The owner of record in NYC Department of City Planning PLUTO data is Rsh Properties LLC.
Does 150 East 45 Street have violations?
NYC HPD has no housing violations on record for this property.
Is 150 East 45 Street rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 150 East 45 Street built?
City records list 1950 as the year it was built.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.