roofy

761 5 Avenue

Manhattan, NY 10022BBL 1-01294-0001Map

Owner of record: 767 Fifth Partners LLC

761 5 Avenue is an office building built in 1968 in Manhattan, 10022. The owner of record is 767 Fifth Partners LLC. HPD has no housing violations on record for this property.

HPD violations
0
DOB violations
479
ECB violations
101
HPD complaints
9

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
No HPD violations

HPD has not cited this building.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 0

No HPD violations on record

DOB building violations · 479

  • Failure to post energy grade/score none

    Failure to display energy efficiency score and energy efficiency grade as per adcode sec. 28-309.12.3

    Dec 1, 2022

    Dob violation - active
  • No report and / or late filing (facade) facade required

    Failed to file fisp cycle 9a technical report by 02/21/2022

    Feb 22, 2022

    Dob violation - dismissed
  • Failure to post energy grade/score none

    Failure to display energy efficiency score and energy efficiency grade as per adcode sec. 28-309.12.3

    Dec 1, 2021

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 21, 2020

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 21, 2020

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 21, 2020

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 21, 2020

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 21, 2020

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 18, 2020

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 18, 2020

    Dob violation - resolved
Show 40 more ↓
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 18, 2020

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 15, 2020

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 15, 2020

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 16, 2019

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 16, 2019

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 16, 2019

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 16, 2019

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 16, 2019

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 16, 2019

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 16, 2019

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 16, 2019

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 13, 2019

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 12, 2019

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Nov 9, 2019

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Nov 9, 2019

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Nov 9, 2019

    Dob violation - resolved
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tst

    Sep 6, 2019

    Dob violation - dismissed
  • Sprinkler none

    Failed to file final sprinkler report by july 1, 2019

    Sep 3, 2019

    Dob violation - dismissed
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    Aug 3, 2019

    Dob violation - dismissed
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    May 2, 2019

    Dob violation - dismissed
  • Elevator annual inspection / test elevatorrequired

    Violation issued to elevator - failure to file category 1 2017 inspection/test

    Apr 5, 2019

    Dob violation - dismissed
  • Elevator annual inspection / test elevatorrequired

    Violation issued to elevator - failure to file category 1 2017 inspection/test

    Apr 5, 2019

    Dob violation - dismissed
  • Elevator annual inspection / test elevatorrequired

    Violation issued to elevator - failure to file category 1 2017 inspection/test

    Apr 5, 2019

    Dob violation - dismissed
  • Elevator annual inspection / test elevatorrequired

    Violation issued to elevator - failure to file category 1 2017 inspection/test

    Apr 5, 2019

    Dob violation - dismissed
  • Elevator annual inspection / test elevatorrequired

    Violation issued to elevator - failure to file category 1 2017 inspection/test

    Apr 5, 2019

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jan 23, 2019

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jan 23, 2019

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 27, 2018

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 27, 2018

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 27, 2018

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 27, 2018

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 27, 2018

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 26, 2018

    Dob violation - resolved
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jul 11, 2018

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst

    Jan 26, 2018

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst

    Jan 26, 2018

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst

    Jan 26, 2018

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst

    Jan 26, 2018

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 15, 2017

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 15, 2017

    Dob violation - resolved

ECB violations · 101

  • Class - 1

    I observed the sidewalk shed in place with the majority of the parapet taller than 4 feet and made of solid material. this creates a dislodgment and struck by hazard. comply with code bc 3307.6.4.6

    Jun 22, 2026

    Resolve
  • Class - 1

    I observed the sidewalk shed vertical members in place at exposure 3 and 4 corner less than 18 inches from the street which is contrary to bc 3307.6.4.4. this creates a vehicle struck by hazard which can collap

    Jun 22, 2026

    Resolve
  • Class - 2

    Stop all suspended scaffold use entire site. counter weights were installed contrary to the design drawings missing one 50.lb plate used to balance adjustable suspension scaffolds that shall be capable of resis

    Jun 16, 2026 · Penalty $625

    Resolve
  • Class - 1

    Stop all facade operations entire. i observed a 50 story building undergoing facade operations with suspended scaffolds in place. my inspection revealed that suspended scaffold workers have not received a site

    Jun 16, 2026 · Penalty $2,500

    Resolve
  • Class - 2

    Failure to comply with the commissioner's order to file a certificate of correction with the department of buildings. at time of inspection,contractor failed to file a certificate of correction for violation #3

    Mar 9, 2026 · Penalty $1,250

    Active
  • Class - 1

    At the time of my inspection-observed shed being installed at exp#3 -upon checking plans vertical posts of sidewalk shed shall be square 4"x4"-installed are square posts- 3"x3"-hazardous condition of collapse o

    Jan 21, 2026 · Penalty $2,500

    Resolve
  • Class - 1

    /bc 3307.6.4.6-shed parapet-observed solid sidewalk shed parapet installed 6 feet high(self certified plans)-not according to code-parapet shall be at least 3 feet m6 inches but no more than 4 feet high-no wire

    Jan 8, 2026 · Penalty $5,000

    Resolve
  • Class - 1

    Observed sidewalk shed at exp#3/4 installed contrary to self certified plans-spacing between posts not as per plan in multiple locations(exp#3 shall be 10'-installed aprox 2/3 ' apart-exp#4-post installed 5 fee

    Jan 8, 2026 · Penalty $2,500

    Resolve
  • Class - 2

    Failure to maintain parking structures in safe condition. as noted: attime of inspection on an occupied parking garage consisting of 01 level. observed multiple cracks at ceiling and floor slabs on the sub-cell

    Dec 31, 2025

    Resolve
  • Class - 2

    Failure to maintain parking structurec in safe condition.as noted at time of inspection on an occupied parking structure consisting of one level below grade level observed cracked concrete slab at various locat

    Sep 27, 2025 · Penalty $1,250

    Resolve
Show 40 more ↓
  • Class - 1

    Failure to maintain parking structure in safe condition.as noted:at time of inspection on an occupied parking garage structure consisting ofone level below grade level,observed:cracked concrete slab at various

    Sep 12, 2025 · Penalty $2,500

    Resolve
  • Class - 2

    27-929.1 failure to complete the installation of a full system of automatic sprinklers and file a final sprinkler report prepared by a registered design professional in an office building 100 feet or more in he

    Feb 28, 2023 · Penalty $6,280

    Resolve
  • Class - 2

    Violation of discretionary zoning conditions of privately owned publicspaces. note at time of inspection 2 overhead canopies installed underpermit#m00655412 expires 7/20/22 for overhead protection. no approval

    Jan 28, 2022 · Penalty $625

    Resolve
  • Class - 2

    27-929.1 ac27-929.1,failure to complete installation of full system ofautomatic sprinklers file final sprinkler report prepared by registered design professional in office bldg 100' or more in ht in existence o

    Mar 30, 2021 · Penalty $3,125

    Resolve
  • Class - 2

    Work does not conform to approved construction document. note: at timeof my inspection,i observed 2 separate shed installed for overhead protection at exp#1 of the bldg w/heating element on top of shed installe

    Feb 5, 2021 · Penalty $625

    Resolve
  • Class - 2

    Sec. 3307.6.4.8 failure to provide lighting. note: at time of my inspection i observed 2 separate shed installed for overhead protection at exp#1 of the bldg w/o electric power source connected. this create uns

    Feb 5, 2021 · Penalty $625

    Resolve
  • Class - 2

    Failure to institute and maintain safety measures note:at the time of my inspection of a 50 story building under interior renovations and demolition on the 2nd floor in response to a report of an incident where

    Sep 29, 2020 · Penalty $625

    Resolve
  • Class - 2

    Sec. ac 27-929.1 failure to complete the installation of a full systemof automatic spriklers & file a final sprinkler report prepared by a registered design professional by 7/1/19,in an office bldg 100 feet or

    Jul 13, 2020 · Penalty $3,125

    Resolve
  • Class - 2

    Ac 27-929.1, failure to complete the installation of a full system of automatic sprinklers & file sprinkler report prepared by a registerd design professional by july 1, 2019, in an office building 100 feet or

    Nov 15, 2019 · Penalty $1,250

    Resolve
  • Class - 1

    Failure to notify the dept of an incident that resulted in a fatality or an injury. a worker cut his wrist while framing duckwork,he was transported to a hospital by an ambulanvce. as per the dept records,the

    Aug 22, 2019 · Penalty $5,000

    Resolve
  • Class - 1

    Work does not conform to approved construction documents/amendments. @the time of inspection of 50 sty building under alteration #122970721 has exterior work with exterior out rigger beams being installed with

    Nov 2, 2018 · Penalty $1,250

    Resolve
  • Class - 1

    Site safety monitoring program.@ time of inspection of 50 sty buildingunder alteration,has exterior work @ roof lvl with no approved site safety plan steel beams with lighting + electrical with safety design ne

    Nov 2, 2018 · Penalty $2,500

    Resolve
  • Class - 2

    Failure to provide dob approved/accepted plans at job site at time of inspection.at time of inspection i observed hmo#9475 alfred macdonald class b in operation of 5000lb max capacity spyder crane hoisting ston

    Oct 22, 2018 · Penalty $250

    Resolve
  • Class - 1

    Work without a permit.at time of inspection i observed hmo#9475 alfredmacdonald class:b operating a 5800lb max capacity syder crane to hoiststone slabs.repspondent was using the crane to perform this work,but n

    Oct 22, 2018 · Penalty $800

    Resolve
  • Class - 1

    Work without a permit.at time of inspection i observed hmo#9475 alred macdonald class:b hoisting stone slabs using a 5800lbs max capacity crane without the required alt2 permit.no one on site could produce the

    Oct 22, 2018 · Penalty $800

    Resolve
  • Class - 2

    Failure to provide dob approved/accepted plans at jobsite at time of inspection while performing an audit inspection,i observed the use of a5800 max capacity spyder crane by hmo#9475 alfre macdonald.mr macdonal

    Oct 22, 2018 · Penalty $250

    Resolve
  • Class - 1

    3303.10 operation in occupied building.note: at the time of my inspection of a 50 story building performing alteration (structural modifica tion)at concourse and sub cellar level construction work in progress

    Jul 30, 2018 · Penalty $2,500

    Resolve
  • Class - 1

    307.7.5 design of fence. note: at the time of my inspection of an alteration operation structural modification of a 50 story buiding at plaza concourse and sub cellar level,construction work in progress. i obs

    Jul 30, 2018 · Penalty $1,250

    Resolve
  • Class - 1

    Work does not conform to approved construction documents and or approved amendments.note: at the time of my inspection of a 50 story building under structural modification on plaza concourse and sub cell

    Jul 30, 2018

    Resolve
  • Class - 1

    Equipment user failed to provide docs on site as required @time of insp, i asked hoist machine operator dominick milone,#7829 & lift director mike hoenig of mobile crane cd4345,cn14118 for required cn plans to

    Apr 9, 2018 · Penalty $2,500

    Resolve
  • Class - 2

    Job site fence not constructed or maintained pursuant.pe section requirements.noted;at time of inspection observed construction wooden fenceinstalled under job #123056012,however fence does not conform with loc

    May 15, 2017

    Resolve
  • Class - 1

    86i11,99bb07,89h10 cease use item. 86i11-repalce damaged comb plate teet at top landing; 99bb07-provide current 1year test tag; 89h10-repair worn steps. cease use item must be repaired asap.

    Sep 3, 2014 · Penalty $1,000

    Resolve
  • Class - 1

    Failure to safeguard all persons & property affected by const operations.noticed @ time of insp incident-workers working on suspended scaffold doing facaded work on 42nd fl when worker dropped scraping razor ap

    Jul 1, 2014 · Penalty $2,400

    Resolve
  • Class - 2

    Failure to maintain exterior building wall in that an approx 30'high and 10'wide glass panel has shattered at front entranceway to apple store. vacate area beneath broken panel and also exterior plaza adjac

    Jan 22, 2014 · Penalty $250

    Resolve
  • Class - 2

    28-116.4.1)(97r07)operating a device w/o a cert of compliance.no report of inspec submitted to dob & no witnessing of test by dob.remedy:contact dob to schedule test appt to obtain cert of compliance under ebn8

    Jul 2, 2012 · Penalty $400

    Resolve
  • Class - 2

    Work does not conform to approved construction documents and/or approved amendments for alt 2 job #110090393 of which permit expired 2.13.09. non-conforming work noted @ north corridor of 45th flr - img world

    Dec 8, 2011 · Penalty $500

    Resolve
  • Class - 1

    Sec. 3310.6 failure to have designated ssn/ssc as indicated on pw2 present on site at minimum of once every 2# weeks: examination of site safety log from april -june indicates that ssn #1403 so designated on

    Jun 21, 2011 · Penalty $1,600

    Resolve
  • Class - 1

    Failure to safeguard all persons and property affected by constructionoperations. noted: temporary rigging installation in progress whereas man lift "genie" had toppled & fallen onto large sign approx 10'x 15'

    May 20, 2010

    Resolve
  • Class - 1

    Failure to maintain bldg in code-compliant manner. interior 1st flr directional sign 10' x 15' damaged directional arrow broken off. remedy:immediately make safe - provide structural engineer's report on

    May 20, 2010 · Penalty $1,000

    Resolve
  • Non-hazardous

    64x10,60r11,81x10,80h11,83o02. 60r-replace it so that reading access can be attained.81x-top 80h-step chain (properly file & obtain permit)83o-perform a full clean down inside entire equipment.

    Feb 4, 2008 · Penalty $180

    Resolve
  • Non-hazardous

    84j10.84-vibration in lower end(problem in turn around)repair.

    May 14, 2007 · Penalty $350

    Resolve
  • Non-hazardous

    Cease use.hazardous.84m07/84b01/58l10/84m07/8o02.cease use items.84-ceiling intersection guard missing,provide.84-excessive skirtclearance adjust.58-brake stopping too short adjust brake or repair.cease use

    Sep 25, 2006 · Penalty $500

    Resolve
  • Non-hazardous

    Noted: failure to post permit holder sign as required by admin. code. remedy: post sign as required.

    Feb 3, 2006 · Penalty $200

    Resolve
  • Non-hazardous

    Noted: expired sidewalk shed permit issued under 104023343 on 2/2/5 expired 12/31/05. remedy: renew permit.

    Feb 3, 2006 · Penalty $250

    Resolve
  • Non-hazardous

    86m07/*x10/x10 (86) no current two-year test tag present; provide (*) demarcation lighting inoperative; repair stop switch buzzer on top andinoperative; repair.

    Jan 25, 2006 · Penalty $180

    Resolve
  • Non-hazardous

    77i11/86m07/x10/*x10 (77) several comb plate teeth missing at top end open it; replace comb plates (86) no current two-year test tag present-provide stop switch buzzer inoperative on top end inoperative; repair

    Jan 25, 2006 · Penalty $180

    Resolve
  • Non-hazardous

    86m07 (86) no current two year test tag present; provide.

    Jan 25, 2006 · Penalty $180

    Resolve
  • Non-hazardous

    86u05/81i10/77i10 86) two year test- perform and file 81) key switch cover damaged 77) comb plate teeth.

    Jan 25, 2006 · Penalty $180

    Resolve
  • Non-hazardous

    86u05/79a10/81i10 86) two year test- perform and file test 79) handrail chain (left) 81) key switch covers damaged.

    Jan 25, 2006 · Penalty $180

    Resolve
  • Non-hazardous

    82x10/83o02/83u7/86u05 82x- inaudible button 83o- perform a full cleandown.

    Oct 6, 2005 · Penalty $180

    Resolve

Complaints

  • Heat/hot water

    Entire building

    Jan 2, 2026 · Apt BLDG

    Close
  • Heat/hot water

    Entire building

    Feb 2, 2025 · Apt BLDG

    Close
  • Heat/hot water

    Entire building

    Dec 31, 2018 · Apt BLDG

    Close
  • Heat/hot water

    Entire building

    Jan 2, 2018 · Apt BLDG

    Close
  • Heat/hot water

    Entire building

    Jan 1, 2018 · Apt BLDG

    Close
  • Heat/hot water

    Entire building

    Dec 30, 2017 · Apt BLDG

    Close
  • Heat/hot water

    Entire building

    Mar 13, 2017 · Apt BLDG

    Close
  • Heat/hot water

    Entire building

    Jan 8, 2017 · Apt BLDG

    Close
  • Heating

    Heat related

    Dec 4, 2010 · Apt 4R

    Close

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Office building (O4)
Year built
1968
Floors
50
Residential units
—
Building area
1,824,820 ft²
Lot area
84,350 ft²
Zoning
C5-3
Community board
105
Council district
4
Block / lot
1294 / 1
Assessed value
$826,881,300
Landmark / historic district
No

Questions about 761 5 Avenue

Who owns 761 5 Avenue?

The owner of record in NYC Department of City Planning PLUTO data is 767 Fifth Partners LLC.

Does 761 5 Avenue have violations?

NYC HPD has no housing violations on record for this property.

Is 761 5 Avenue rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was 761 5 Avenue built?

City records list 1968 as the year it was built.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.