3 East 57 Street
Manhattan, NY 10022BBL 1-01293-0005Map
Owner of record: Dixson Assocs. LLC
3 East 57 Street is an office building built in 1930 in Manhattan, 10022. The owner of record is Dixson Assocs. LLC. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 44
- ECB violations
- 11
- HPD complaints
- 1
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 44
- Elevator elevatorrequired
E-elevator elevatorrequired
Dec 21, 2021
Dob violation - resolved - Sprinkler none
Failed to file final sprinkler report by july 1, 2019
Sep 3, 2019
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Aug 2, 2019
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
May 2, 2019
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst
Jan 26, 2018
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Dec 11, 2017
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Dec 11, 2017
Dob violation - resolved - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2016 inspection/test
Sep 15, 2017
Dob violation - active - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2016 inspection/test
Sep 15, 2017
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Nov 17, 2015
Dob violation - resolved
Show 34 more ↓
- Elevator elevatorrequired
E-elevator elevatorrequired
Nov 17, 2015
Dob violation - resolved - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2014 inspection/test
Jun 10, 2015
Dob violation - active - Elevator elevatorrequired
E-elevator elevatorrequired
Dec 4, 2014
Vw*-violation - work w/o permit dismissed - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2013 inspection/test
Oct 31, 2014
Dob violation - active - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2012 inspection/test
Mar 31, 2014
Dob violation - active - No report and / or late filing (facade) facade required
Failed to file fisp cycle 7c technical report by 02/21/2013
Dec 31, 2013
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Mar 12, 2013
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Mar 12, 2013
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Mar 12, 2013
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Apr 20, 2012
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Apr 19, 2012
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Apr 19, 2012
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jul 5, 2011
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jul 5, 2011
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jul 5, 2011
Dob violation - resolved - Elevator annual inspection / test elevatorrequired
Vcat1-elevator annual inspection / test elevatorrequired
Oct 8, 2010
Dob violation - active - Elevator elevatorrequired
E-elevator elevatorrequired
Sep 2, 2010
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Sep 2, 2010
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jan 15, 2008
Dob violation - resolved - Elevator elevatoroptional
Ll1081-local law 10/81 - elevator elevatoroptional
Apr 2, 2007
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Jan 30, 2007
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jan 30, 2007
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 8, 2006
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 8, 2006
Dob violation - resolved - Elevator elevatoroptional
Ll1081-local law 10/81 - elevator elevatoroptional
Oct 1, 2005
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Jan 4, 2005
Vw*-violation - work w/o permit dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Jan 4, 2005
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jan 4, 2005
Dob violation - resolved - Elevator elevatoroptional
Ll1081-local law 10/81 - elevator elevatoroptional
Nov 19, 2004
Dob violation - dismissed - Elevator elevatoroptional
Ll1081-local law 10/81 - elevator elevatoroptional
Apr 21, 2004
Dob violation - dismissed - Elevator elevatorrequired
1p18435
Jul 27, 2001
Dob violation - resolved - Elevator elevatorrequired
1p18435
Nov 9, 1999
Dob violation - resolved - Elevator elevatorrequired
1p31341
Nov 9, 1999
Dob violation - resolved - Elevator elevatoroptional
Ll1081-local law 10/81 - elevator elevatoroptional
Mar 8, 1996
Dob violation - dismissed
ECB violations · 11
- Class - 2
27-929.1 failure to complete the installation of a full system of automatic sprinklers and file a final sprinkler report prepared by a registered design professional in an office building 100 feet or more in he
Nov 1, 2021 · Penalty $1,250
Resolve - Class - 2
Ac 27-929.1, failure to complete the installation of a full system of automatic sprinklers & file sprinkler report prepared by a registerd design professional by july 1, 2019, in an office building 100 feet or
Nov 15, 2019 · Penalty $1,250
Resolve - Class - 2
Failure to file an acceptable cycle 7 technical report in compliance with code provisions: periodic inspection of exterior walls & appurtenances as required by article 28-302 & the dept of bldgs rules & regulat
Dec 22, 2014 · Penalty $800
Resolve - Non-hazardous
60m07.44m13.84r09.60m provide emergency phone # on main line 44m provide seal on governor 84r remove spronkler from mr
Jun 4, 2008 · Penalty $180
Resolve - Non-hazardous
39s0716b0166p16. 39s provide fire retardant roof above controller. 16badjust hoistway door on lobby to be self closing 66p provide proper access to pit drop does not fit in hole.
Apr 7, 2008 · Penalty $180
Resolve - Non-hazardous
85 bb 5/85-expired 5yr 11-2001-perform & file test
Jan 12, 2007 · Penalty $180
Resolve - Non-hazardous
Failure to post sign on shed as required by local law 33/91. as noted:no contractor's sign or permit posted on sidewalk shed. no exterior activity upon inspection. remedy:post sign & permit as per code.
May 13, 2006
Resolve - Non-hazardous
08v01-74x11-12x11-15b06-22w06-21d06-20d06-20x11-10m12-36b07-74x11. 08-v-01 basement floor not level off 1/4 adjust leveling 74-x-11 phone communication inoperatiue repary phone 15-b-06 basement hall door sight
Sep 24, 2002
Resolve - Non-hazardous
75u, tag device for five year test, current test tag show only two year.
Nov 23, 1999
Resolve - Non-hazardous
35o2,57o2,30q3,15d6. -30 installed guard rail on the top of car for safety, -15 hoistway door molding on basement floor is very loose
Nov 4, 1998
Resolve
Show 1 more ↓
- Non-hazardous
Altered building occupied without a valid certificate of occupancy alt. 55/85. remendy: obtain a c of o.
Jan 22, 1992 · Penalty $285
Resolve
Complaints
- Heating
Heat related
Mar 25, 2009 · Apt 4B
Close
Sales history
No recorded sales in our data
Building details
- Building type
- Office building (O6)
- Year built
- 1930
- Floors
- 9
- Residential units
- —
- Building area
- 42,500 ft²
- Lot area
- 4,259 ft²
- Zoning
- C5-3
- Community board
- 105
- Council district
- 4
- Block / lot
- 1293 / 5
- Assessed value
- $47,832,300
- Landmark / historic district
- INDIVIDUAL LANDMARK
Questions about 3 East 57 Street
Who owns 3 East 57 Street?
The owner of record in NYC Department of City Planning PLUTO data is Dixson Assocs. LLC.
Does 3 East 57 Street have violations?
NYC HPD has no housing violations on record for this property.
Is 3 East 57 Street rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 3 East 57 Street built?
City records list 1930 as the year it was built.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.