49 West 45 Street

Manhattan, NY 10036BBL 1-01261-0015Map

Owner of record: Famurb Company

49 West 45 Street is an office building built in 1922 in Manhattan, 10036. The owner of record is Famurb Company. HPD has no housing violations on record for this property.

HPD violations
0
DOB violations
64
ECB violations
25
HPD complaints
2

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
No HPD violations

HPD has not cited this building.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 0

No HPD violations on record

DOB building violations · 64

  • Construction other optional

    Emergency work order due to cracked/spalling masonry cornice new roof lvl. defective/spalling brk near roof lvl. cracked,spalling coping stones @ mult setback locations. remedy:immed take/provide safe meas & install pub prot exp1 s ele. additionally remove/secure loose/hangin material. make repairs u/supervision of a licensed professional

    Jul 9, 2026

    Dob violation - active
  • Failure to submit eer none

    Failure to submit an eer per ad. code sec. 28-308.4 in 2021

    Aug 21, 2022

    Dob violation - dismissed
  • Failure to post energy grade/score none

    Failure to display energy efficiency score and energy efficiency grade as per adcode sec. 28-309.12.3

    Apr 29, 2021

    Dob violation - active
  • Hazardous condition (facade) facade required

    Cycle 9c unsafe report filed

    Nov 2, 2020

    Dob violation - active
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tst

    Sep 6, 2019

    Dob violation - active
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tst

    Sep 6, 2019

    Dob violation - active
  • Sprinkler none

    Failed to file final sprinkler report by july 1, 2019

    Sep 3, 2019

    Dob violation - active
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2016 inspection report

    Apr 6, 2018

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst

    Jan 26, 2018

    Dob violation - active
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst

    Jan 26, 2018

    Dob violation - active
Show 40 more ↓
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2014 cat 1 insp/tst

    Nov 14, 2016

    Dob violation - active
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2014 cat 1 insp/tst

    Nov 14, 2016

    Dob violation - active
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2014 cat 1 insp/tst

    Nov 14, 2016

    Dob violation - active
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    Feb 2, 2016

    Dob violation - active
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    Nov 2, 2015

    Dob violation - active
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    Aug 2, 2015

    Dob violation - active
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    May 2, 2015

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Sep 30, 2014

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Sep 30, 2014

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Sep 30, 2014

    Dob violation - resolved
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    Jun 6, 2014

    Dob violation - active
  • No report and / or late filing (facade) facade required

    Failed to file fisp cycle 7c technical report by 02/21/2013

    Dec 31, 2013

    Dob violation - active
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    Jun 3, 2013

    Dob violation - active
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Sep 20, 2012

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Sep 20, 2012

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Sep 20, 2012

    Dob violation - resolved
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    May 3, 2012

    Dob violation - active
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    Jan 1, 2012

    Dob violation - active
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jun 8, 2011

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jun 7, 2011

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jun 7, 2011

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jun 7, 2011

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Aug 3, 2009

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Aug 3, 2009

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Aug 3, 2009

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Apr 30, 2008

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Apr 30, 2008

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Apr 30, 2008

    Dob violation - resolved
  • Facade facade optional

    Ll1198-local law 11/98 - facade facade optional

    Nov 30, 2007

    Dob violation - active
  • Facade facade optional

    Ll1198-local law 11/98 - facade facade optional

    Nov 30, 2007

    Dob violation - active
  • Photoluminescent none

    Ll2604-photoluminescent none

    Nov 1, 2006

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jul 1, 2005

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jul 1, 2005

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jul 1, 2005

    Dob violation - resolved
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jan 31, 2005

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jan 22, 2004

    Dob violation - resolved
  • Facade facade required

    L1198-local law 11/98 - facade facade required

    Aug 8, 2002

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 27, 2001

    Dob violation - dismissed
  • Elevator elevatorrequired

    1p12467

    Feb 15, 2001

    Dob violation - resolved
  • Elevator elevatorrequired

    1p12469

    Mar 14, 2000

    Dob violation - resolved

ECB violations · 25

  • Class - 1

    Failure to maintain bldg exterior facade and appurtenances. note: at time of inspection i observed cracked masonry banding at upper level and at water table of exp #1 south.-exp #2 west-(1)defective/spalling br

    Jul 9, 2026 · Penalty $5,000

    Active
  • Class - 2

    Failure to file acceptable amended cycle 8c and 9c report indicating correction of unsafe conditions described in initial facades report required by 28-302.5 for control #904108. agg1: prior nov 37026219k under

    Apr 20, 2026 · Penalty $10,000

    Active
  • Class - 2

    Failure to file acceptable amended cycle 8c & 9c report indicating correction of unsafe conditions described in initial facades report required by 28-302.5 for control #904108.remedy:file acceptable report

    Jan 16, 2024 · Penalty $6,250

    Active
  • Class - 2

    Failure to file acceptable amended cycle 8c & 9c report indicating correction of unsafe conditions described in initial facades report required by 28-302.5 for control#904108. remedy: file acceptable report.

    Oct 8, 2021

    Resolve
  • Class - 2

    27-929.1 ac27-929.1,failure to complete installation of full system ofautomatic sprinklers&file final sprinkler report prepared by registered design professional in office bldg 100' or more in ht in existence o

    Mar 30, 2021

    Resolve
  • Class - 2

    Ac 27-929 failure to complete the installation of a full system of automatic sprinlers and file a final sprinkler report prepared by a registered design professional by july 1, 2019 in an office building 100 fe

    Jul 13, 2020 · Penalty $3,155

    Active
  • Class - 2

    Failure to submit an acceptable required cycle 8c report of critical examination documenting condition of exterior wall & appurtenances required by 28-302.4 for control#804108. remedy: submit acceptable require

    Feb 13, 2020 · Penalty $1,280

    Active
  • Class - 2

    Ac279291-failure to complete the installation of a full system of automatic sprinklers and file a final sprinkler report prepared by a registered design professional by july 1,2019,in an office building 100 fee

    Nov 15, 2019 · Penalty $6,250

    Active
  • Class - 2

    Failure to file an acceptable 6th round technical report in compliancew/article 28-302 of the bldg code and dob's rules and regulations. respondent has demonstrated a history of non-compliance w/dept rules and

    Jun 29, 2012 · Penalty $10,000

    Active
  • Class - 2

    Failure to file an acceptable 6th round technical report in compliance with code provisions: periodic inspection of exterior walls & appurtenances as required by article 28.302 & the dept of bldgs rules & regul

    Dec 15, 2011 · Penalty $1,000

    Active
Show 15 more ↓
  • Class - 2

    Failure to file an acceptable sixth round technical report in compliance w/ code provisions periodic insp of exterior walls and appurtenances as required by article 28.302 and the dob rules and regulations rem:

    Jan 25, 2011

    Resolve
  • Class - 2

    Failure to file an acceptable sixth round technical report in compliance w/ code provisions periodic insp of exterior walls and appurtenances as required by article 28.302 and the dob rules and regulations rem:

    Jan 25, 2011 · Penalty $2,000

    Active
  • Class - 2

    Failure to file an acceptable sixth round technical report in compliance w/ code provisions: periodic inspection of exterior walls & appurtenances as required by article 28.302 & the d.o.b. rule and regulations

    May 10, 2010 · Penalty $8,000

    Active
  • Class - 2

    Failure to file an acceptable sixth round technical report in compliance w/ code provisions: periodic inspection of exterior walls & appurtenances as required by article 28.302 & the d.o.b. rule and regulations

    May 10, 2010 · Penalty $8,000

    Active
  • Class - 2

    Failure to safeguard all persons & property affected by construction operations: at west side of property @ 2nd flr level workers under job application #120040204 have damaged barber shop "barbers pole".

    May 28, 2009

    Resolve
  • Class - 2

    Failure to submit an acceptable sixth round technical report in compliance w/code provisions periodic inspection of exterior walls & appurtenances as required by article 28.302 and the dept of bldg rules & regu

    Dec 12, 2008 · Penalty $800

    Active
  • Class - 2

    Failure to submit an acceptable 6th round technical report in compliance with code provisions: periodic inspection of exterior walls & appurtenances as required by article 28.302 & the dept of buildings rules &

    Dec 12, 2008

    Resolve
  • Non-hazardous

    41g07,55y13.41-improper fusing-shunt across fuse,unable to verift amperage on another fuse.55-oil leak-reseal.

    Feb 26, 2007

    Resolve
  • Non-hazardous

    85u05 85-perform and file 5yrs test

    Mar 22, 2004

    Resolve
  • Non-hazardous

    20m7. install new hall button station on the lobby floor as stated on application ebn 699-02 to comply with ansi a1711. rs 18 paes x 11.

    Sep 10, 2002

    Resolve
  • Non-hazardous

    Instllation of mechacial equipment without first obtaining a equipment use permit for a/c unit on roof remedy obtain a equipment use permit from this departmnet

    Aug 21, 1997

    Resolve
  • Non-hazardous

    Failure to provide emergency lighting facilities on 1) tenant cordior ,floors 11,10,9,8,7, and 2) staircases b & c on every floor. failure to provide emergency power to 1) lighting facilities on tenant corrido

    Dec 11, 1996 · Penalty $525

    Resolve
  • Non-hazardous

    Failure to file a report of compliance with local law 16/84 certifying to the installation or required fire protection systems.

    Dec 11, 1996 · Penalty $400

    Resolve
  • Non-hazardous

    Failure to provide elevator sign at freight elevator bank "d" on floors 2 to 12 including basement. remedy: install sign as per code ll16/84

    Dec 11, 1996 · Penalty $200

    Resolve
  • Non-hazardous

    17i, (17) replace broken vision glass in basement door.

    Jan 8, 1991

    Resolve

Complaints

  • Heating

    Heat related

    Nov 8, 2010 · Apt 33

    Close
  • Heating

    Heat related

    Nov 2, 2010 · Apt 33

    Close

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Office building (O6)
Year built
1922
Floors
12.5
Residential units
—
Building area
59,841 ft²
Lot area
5,649 ft²
Zoning
C6-4.5
Community board
105
Council district
4
Block / lot
1261 / 15
Assessed value
$4,983,300
Landmark / historic district
No

Questions about 49 West 45 Street

Who owns 49 West 45 Street?

The owner of record in NYC Department of City Planning PLUTO data is Famurb Company.

Does 49 West 45 Street have violations?

NYC HPD has no housing violations on record for this property.

Is 49 West 45 Street rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was 49 West 45 Street built?

City records list 1922 as the year it was built.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.