roofy

315 West 53 Street

Manhattan, NY 10019BBL 1-01044-0024Map

Owner of record: Ada B LLC

315 West 53 Street is an office building built in 1920 in Manhattan, 10019. The owner of record is Ada B LLC. HPD has no housing violations on record for this property.

HPD violations
0
DOB violations
9
ECB violations
15
HPD complaints
0

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
No HPD violations

HPD has not cited this building.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 0

No HPD violations on record

DOB building violations · 9

  • Low pressure boiler boiler required

    Violation issued-failure to file 2024 external low pressure inspection

    Nov 14, 2025

    Dob violation - active
  • Low pressure boiler boiler required

    Violation issued-failure to file 2018 external low pressure inspection

    Jun 20, 2023

    Dob violation - active
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2017 inspection report

    Nov 8, 2019

    Dob violation - active
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2016 inspection report

    Apr 6, 2018

    Dob violation - dismissed
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2014 inspection report

    Oct 1, 2015

    Dob violation - dismissed
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2013 inspection report

    Mar 3, 2015

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Mar 16, 1999

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Aug 29, 1995

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Sep 1, 1994

    Dob violation - dismissed

ECB violations · 15

  • Class - 1

    At the time of my inspection observed inadequate shoring in cellar level. upon request no details for inadequate shoring was provide. 28-105.12.2 shoring work does not conform with approve drawings under permit

    Jun 4, 2026 · Penalty $12,500

    Active
  • Class - 1

    At the time of my inspection observed steel beam above window frame installed without design drawings@2nd level, no details for steel beam attach to wood joists, steel beam with inadequate splice plates @level

    Jun 4, 2026 · Penalty $12,500

    Active
  • Class - 1

    At the time of my inspection observed cold form steel without blocking or strap bridging on floors 2,3,4,5. no design drawings for cold form steel connections with steel beam structure on 3rd fl. 28-105.12.2 up

    Jun 4, 2026 · Penalty $12,500

    Active
  • Class - 1

    At the time of my inspection observed cs failed to perform duties per code, no plans was provided upon request of competent person inadequate erection of steel beam above window panel without approve design dra

    Jun 4, 2026 · Penalty $10,000

    Active
  • Class - 2

    At the time of inspection of a 5-story building, a sidewalk shed was in place contrary to approved drawings. at exp# 2, catch-all installed without required planking and plywood, compromising stability and crea

    Apr 16, 2026 · Penalty $6,250

    Active
  • Class - 2

    Bc 3305.3.3.3: at the time of inspection of a 5-story building, cold-formed steel work was observed. upon request, no special inspection report was provided. stop all structural work and provide required specia

    Apr 16, 2026 · Penalty $10,000

    Active
  • Class - 2

    3314.3.4 at time of inspection of a 5 stories building under structural permit i observed supported scaffold installed on top of sidewalk shed, upon request for load imposed letter from the registered profess

    Jan 30, 2026 · Penalty $2,500

    Resolve
  • Class - 2

    At time of inspection of a 5 stories building under structural permit i observed supported scaffold installed on top of sidewalk shed, upon request for permit and upon review the department record to verify c

    Jan 30, 2026

    Resolve
  • Class - 2

    During my inspection of an active alt site, i reviewed the site history. i observed that the permit holder has failed to file an accepted certificate of correction with the department ref- 39540770r issued on 5

    Jul 23, 2025 · Penalty $3,125

    Resolve
  • Class - 2

    During my inspection of an active alt site, i reviewed the site history. i observed that the permit holder has failed to file an accepted certificate of correction with the department ref- 39540771z issued on 5

    Jul 23, 2025 · Penalty $3,125

    Resolve
Show 5 more ↓
  • Class - 1

    At time of inspection observed active underpinning activities. upon inspecting approved plans notice work out of sequence. as per drawings it shows rakers to be installed prior the global excavation. on page 4

    May 28, 2025 · Penalty $2,530

    Resolve
  • Class - 1

    At time of inspection observed active underpinning activities. excavation work is substantially completed. upon further research found out no require earth work notification prior to commencement or earth work

    May 28, 2025 · Penalty $2,530

    Resolve
  • Class - 1

    At time of inspection observed active construction site currently doing underpinning. safety violating conditions found during inspection. upon requesting daily log for construction super, cp provide log that w

    May 27, 2025 · Penalty $12,500

    Resolve
  • Class - 2

    At time of inspection observed active underpinning work on site. upon requesting the following documents soe/underpinning drawings, adequate site safety plan (not sign), sws drawings, letter of installation for

    May 27, 2025 · Penalty $1,280

    Resolve
  • Class - 1

    At time of inspection observed active construction activities. upon requesting pre-shifts cp provided a folder of inadequate pre-shifts. no information of daily activities/task and no notes about safety concern

    May 27, 2025 · Penalty $5,030

    Resolve

Complaints

No HPD complaints in our records

Complaint data is still being backfilled from NYC Open Data.

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Office building (O2)
Year built
1920
Floors
3
Residential units
—
Building area
2,430 ft²
Lot area
800 ft²
Zoning
R8
Community board
104
Council district
3
Block / lot
1044 / 24
Assessed value
$398,700
Landmark / historic district
No

Questions about 315 West 53 Street

Who owns 315 West 53 Street?

The owner of record in NYC Department of City Planning PLUTO data is Ada B LLC.

Does 315 West 53 Street have violations?

NYC HPD has no housing violations on record for this property.

Is 315 West 53 Street rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was 315 West 53 Street built?

City records list 1920 as the year it was built.