roofy

206 West 41 Street

Manhattan, NY 10036BBL 1-01012-0037Map

Owner of record: Nederlander Theatrical

206 West 41 Street is a hotel built in 1900 in Manhattan, 10036. It has 47 residential units across 6 floors. The owner of record is Nederlander Theatrical. HPD has recorded 7 housing violations here, most recently on June 4, 2025.

HPD violations
7
DOB violations
43
ECB violations
22
HPD complaints
0

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
Last violation Jun 4, 2025

Date of the most recent HPD inspection that found a problem.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 7

  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Jun 4, 2025

    Closed — Violation dismissed
  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Apr 1, 2024

    Closed — Violation dismissed
  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Feb 16, 2022

    Closed — Violation dismissed
  • A

    File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.

    Apr 1, 2021

    Closed — Violation dismissed
  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Oct 10, 2018

    Closed — Violation dismissed
  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Oct 2, 2015

    Closed — Violation dismissed
  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Feb 3, 2015

    Closed — Violation dismissed

DOB building violations · 43

  • Hazardous condition (facade) facade required

    Cycle 9c unsafe report filed

    Sep 19, 2023

    Dob violation - dismissed
  • Low pressure boiler boiler required

    Violation issued-failure to file 2022 external low pressure inspection

    Apr 25, 2023

    Dob violation - dismissed
  • Low pressure boiler boiler required

    Violation issued-failure to file 2022 external low pressure inspection

    Apr 25, 2023

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tst

    Sep 6, 2019

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2012 cat 1 insp/tst

    May 30, 2014

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    May 22, 2013

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    May 22, 2013

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Mar 13, 2013

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Mar 13, 2013

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Aug 5, 2010

    Dob violation - resolved
Show 33 more ↓
  • Construction other optional

    C-construction other optional

    May 8, 2010

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Aug 12, 2008

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jul 20, 2007

    Vw*-violation - work w/o permit dismissed
  • Elevator elevatoroptional

    Ll1081-local law 10/81 - elevator elevatoroptional

    Apr 2, 2007

    Dob violation - dismissed
  • Elevator elevatoroptional

    Ll1081-local law 10/81 - elevator elevatoroptional

    Oct 1, 2005

    Dob violation - dismissed
  • Elevator elevatoroptional

    Ll1081-local law 10/81 - elevator elevatoroptional

    Nov 19, 2004

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Aug 27, 2004

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Aug 27, 2004

    Vw*-violation - work w/o permit dismissed
  • Elevator elevatoroptional

    Ll1081-local law 10/81 - elevator elevatoroptional

    Apr 21, 2004

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Sep 26, 2003

    Dob violation - resolved
  • Elevator elevatoroptional

    Ll1081-local law 10/81 - elevator elevatoroptional

    Mar 21, 2003

    Dob violation - dismissed
  • Elevator elevatoroptional

    Ll1081-local law 10/81 - elevator elevatoroptional

    Feb 19, 2002

    Dob violation - dismissed
  • Elevator elevatoroptional

    Ll1081-local law 10/81 - elevator elevatoroptional

    Mar 8, 2001

    Dob violation - dismissed
  • Elevator elevatoroptional

    Ll1081-local law 10/81 - elevator elevatoroptional

    Mar 10, 2000

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 7, 2000

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Mar 16, 1999

    Dob violation - dismissed
  • Elevator elevatoroptional

    Ll1081-local law 10/81 - elevator elevatoroptional

    Jan 20, 1999

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    May 4, 1998

    Dob violation - dismissed
  • Elevator elevatoroptional

    Ll1081-local law 10/81 - elevator elevatoroptional

    Jan 6, 1998

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Sep 16, 1997

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 10, 1997

    Dob violation - dismissed
  • Elevator elevatoroptional

    Ll1081-local law 10/81 - elevator elevatoroptional

    Jan 13, 1997

    Dob violation - active
  • Elevator elevatoroptional

    Ll1081-local law 10/81 - elevator elevatoroptional

    Jan 13, 1997

    Dob violation - dismissed
  • Elevator elevatoroptional

    Ll1081-local law 10/81 - elevator elevatoroptional

    Mar 8, 1996

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Aug 29, 1995

    Dob violation - dismissed
  • Elevator elevatoroptional

    Ll1081-local law 10/81 - elevator elevatoroptional

    Apr 17, 1995

    Dob violation - dismissed
  • Elevator elevatoroptional

    Ll1081-local law 10/81 - elevator elevatoroptional

    May 31, 1994

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Mar 18, 1994

    Dob violation - dismissed
  • Elevator elevatoroptional

    1

    Jun 28, 1993

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Mar 18, 1993

    Dob violation - dismissed
  • Elevator elevatoroptional

    1

    Apr 7, 1992

    Dob violation - dismissed
  • Elevator elevatoroptional

    1

    Apr 25, 1991

    Dob violation - dismissed
  • Elevator elevatoroptional

    1

    Jun 29, 1990

    Dob violation - dismissed

ECB violations · 22

  • Class - 1

    Ceased use 2 lochinvar model # cwn360pm water heater due to hazardous condition, as reported by utility company gas fired water heater spilling high levels of c.o. 300ppm do not operate water heater until all h

    Jul 30, 2025 · Penalty $2,500

    Active
  • Class - 1

    Failure to maintain exterior building facade and appurtenances. observed loose railing is not attached to substrate at penthouse tarrace(6 story setback roof at front facade) 6th floor. remedy: maintain exterio

    Oct 17, 2023 · Penalty $2,500

    Resolve
  • Class - 1

    Cu 5a10;5-a-10 door zone restrictor has been tampered with disabled & rendered inoperative.this is a safety device to ensure passengers' safety.repair restrictor & contact nyc dob @ [email protected]& call

    Apr 9, 2019 · Penalty $1,250

    Resolve
  • Class - 2

    16p07,70p16,100b07,60i10,40z10,100i10,98bb09,12b11,41b07. 16p-no access to key hole at lobby hall door provide access; 70p-provide access to pit; 100b-in shaftway a 4"ledge needs to be beveled-provide a 30"

    Feb 28, 2013

    Resolve
  • Class - 1

    Sec. 508.3 failure to provide required fire separation. noted: on ground floor (bsmt floor per tco #102574288) no fire separation between 2 occupancies as hotel & eating/drinking establishment. remedy: provide

    Feb 19, 2013 · Penalty $1,600

    Resolve
  • Class - 1

    Sec. 1008.1.2.2 failure to comply w/the direction of swing. noted: fire exit doors on hotel floors 1st to 6th leading to the fire escape stairs in front of bldg. swing against of the direction of egress travel

    Feb 19, 2013 · Penalty $1,600

    Resolve
  • Class - 2

    Work does not conform to approved construction documents &/or approvedamendments. noted: on hotel floors 1st to 6th floor public hallways erected door/patio doors contrary to approved plans #102574288 approved

    Feb 19, 2013 · Penalty $500

    Resolve
  • Class - 1

    Failure to provide unobstructed exit passageway. noted: exit passageway. noted: exit passageways obstructed by furniture,luggage,boxes on various locations. remedy: remove obstruction.

    Dec 11, 2012 · Penalty $1,200

    Resolve
  • Class - 1

    Failure to maintain bldg in code compliant manner. defects noted: (1) no fire stopping in cellar at various locations per bc 712.3;27-345 (2) having steel beams located at cellar level w/o providing fire

    Dec 11, 2012 · Penalty $1,000

    Resolve
  • Class - 1

    Sec. 1008.1.2.2 failure to comply w/the direction of swing. noted: allexit doors leading to fire escape swing against of direction of egresstravel. remedy: comply w/code.

    Dec 11, 2012 · Penalty $1,600

    Resolve
Show 12 more ↓
  • Class - 1

    Sec. 1004.1.2 failure to comply w/maximum floor area requirements per occupant load noted: rooms occupied as a transient hotel/hostel & being occupied by up to 12 occupants (equipped & arranged) rooms #702,701,

    Dec 11, 2012 · Penalty $1,600

    Resolve
  • Class - 1

    Failure to maintain bldg in code compliant manner use of prohibited door &/or hardware per bc1008.1.8;27-371(j) noted: exit doors at variouslocations having illegal handware. remedy: provide legal hardware.

    Dec 11, 2012 · Penalty $1,000

    Resolve
  • Class - 2

    Altered/changed bldg occupied w/o a valid c/o as per 28-118.3.1-28-118.3.2. noted: bldg altered under appl #102574288-01 and job not signed off. temp c/o #102574288-t-5 expired 4.23.04, flrs 2-6 occupied as

    May 8, 2010 · Penalty $5,000

    Resolve
  • Class - 2

    Work does not conforms to approved plans #102574288 non conforming work noted: land 6th flr layout is not as per plans. no structural (details) for 6th flr & roof. remedy: conform to approved plans or amend pla

    Feb 12, 2009 · Penalty $500

    Resolve
  • Class - 2

    Failure to comply with the commissioner's order to file a certificate of correction with the department of building. for violating conditions sited in vi#34709024y/091608c05kk01. remedy: file c of o.

    Feb 12, 2009 · Penalty $800

    Resolve
  • Class - 2

    Altered/changed building w/o valid c of o as per 28-118.3.1 - 28-118.3.2. noted: tco #102574888-t-5 expired at 4/23/04. remedy: discontinue illegal use or obtain valid certificate of occupancy.

    Feb 12, 2009 · Penalty $500

    Resolve
  • Class - 2

    Operation of a crane/derrick w/o certificate of operation. at time of inspection crane operator produced cd #3333 serial #100666400. cd#333 does not match crane being used. remedy: obtain certificate of approva

    Dec 23, 2008

    Resolve
  • Class - 2

    Operation of a crane/derrick w/o certificate of approved/certificate of operation. remedy: produce sign hangers lic tear off call cod for reinspection.

    Dec 23, 2008

    Resolve
  • Class - 1

    Newbldg or open lot occupied without a valid certificate of occupancy.noted:there was no copy of any c-of-o on site at time of inspection.the attached copy of certicate no 102574288-t-4 expired on 1-17-04 and t

    Sep 16, 2008 · Penalty $5,000

    Resolve
  • Non-hazardous

    Failure to provide approved plans at premises at time of inspection.rem:provide plans.

    Feb 14, 2001

    Resolve
  • Non-hazardous

    Failure to provide approved plan's at premises at time of inspection job #102574288 & 102002574 noted with installation of floor joists andprovide structural stability "structural plan's approved by building

    Aug 31, 2000

    Resolve
  • Non-hazardous

    Work without a permit;work noted: entire building under renovation floor joist's removed 1st and 2nd floors openings in walls between front and rear building noted no permit for this demoltionwork as noted.

    May 25, 2000

    Resolve

Complaints

No HPD complaints in our records

Complaint data is still being backfilled from NYC Open Data.

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Hotel (H3)
Year built
1900
Floors
6
Residential units
47
Building area
11,562 ft²
Lot area
2,469 ft²
Zoning
C6-7
Community board
105
Council district
3
Block / lot
1012 / 37
Assessed value
$3,768,300
Landmark / historic district
No

HPD registration #108102, last renewed Sep 22, 2025.

Questions about 206 West 41 Street

Who owns 206 West 41 Street?

The owner of record in NYC Department of City Planning PLUTO data is Nederlander Theatrical.

Does 206 West 41 Street have violations?

Yes. NYC HPD has recorded 7 housing violations at this property.

Is 206 West 41 Street rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was 206 West 41 Street built?

City records list 1900 as the year it was built.

How many apartments are in 206 West 41 Street?

It has 47 residential units and 48 units in total.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.