roofy

123 West 57th Street

Manhattan, NY 10019BBL 1-01010-7509Map

Owner of record: 125 West 57th Street Property Owner, LLC

123 West 57th Street is a condominium built in 2022 in Manhattan, 10019. The owner of record is 125 West 57th Street Property Owner, LLC. HPD has no housing violations on record for this property.

HPD violations
0
DOB violations
0
ECB violations
20
HPD complaints
0

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
No HPD violations

HPD has not cited this building.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 0

No HPD violations on record

DOB building violations · 0

No DOB violations on record

ECB violations · 20

  • Class - 1

    At time of inspection, observed 3 workers on a pipe scaffold lacking top and mid rails, unsecured planks, and no safe access for ascent or descent. scaffold not maintained or erected per code, creating immediat

    Dec 24, 2025 · Penalty $5,000

    Resolve
  • Class - 1

    Note: at the time of inspection, a review of department records indicated that the permit holder failed to notify the dob of an incident within (3) business days via electronic portal, as required by 28-103.21.

    Dec 15, 2025 · Penalty $10,000

    Resolve
  • Class - 1

    Responding to an incident where a worker fell approximately 10 feet from a system pipe scaffold while he was moving the osha planks. inspection revealed that the incident occurred on 12/04/2025 and was report t

    Dec 5, 2025 · Penalty $5,000

    Resolve
  • Class - 1

    Responding to an incident where a worker fell approximately 10 feet from a system pipe scaffold while he was moving the osha planks. inspection revealed that there were no safety measures in place including no

    Dec 5, 2025 · Penalty $10,000

    Resolve
  • Class - 1

    Responding to an incident where a worker fell approx. 10 ft from a system pipe scaffold while he was moving the osha planks. upon request for worker site safety orientation i was informed that no site orientati

    Dec 5, 2025 · Penalty $5,000

    Resolve
  • Class - 1

    Responding to an incident where a worker fell approx. 10 ft from a system pipe scaffold while he was moving the osha planks. upon request for a copy of worker scaffold certificate to verify that he was certify

    Dec 5, 2025 · Penalty $2,500

    Resolve
  • Class - 1

    At time of inspection, observed workers throughout jobsite using a frame and platform ladders without maintaining 3 points of contact as required by manufacturer specifications. stop all use of ladders provide

    May 13, 2025

    Resolve
  • Class - 1

    At time of inspection, observed an installed temporary platform constructed by placing planks across two baker scaffolds with two workers standing on top. upon request, no design drawings were provided. stop al

    May 13, 2025

    Resolve
  • Class - 1

    At time of inspection, observed suspended scaffold in use at exposure 3 with only 2 j-hooks on wire ropes, contrary to design drawing requiring 3. materials were also stored outside the work platform, contrary

    May 13, 2025

    Resolve
  • Class - 1

    At time of inspection, workers were observed operating a scissor lift without providing the manufacturer's required training certificate upon request, as required by osha and ansi standards. stop all use of sci

    May 13, 2025

    Resolve
Show 10 more ↓
  • Class - 1

    Summons issued for failure to safeguard all persons and operations. electrician was working in the elevator machine room located on top of the roof where he was working on energized transformer box which arced

    Nov 11, 2024

    Resolve
  • Class - 1

    While attempting to lower the debris box into the dumpster the box hit a passing bus causing damage to the bus failure to safeguard all persons and property affected by construction operations., safeguard publi

    Jan 19, 2024 · Penalty $12,500

    Resolve
  • Class - 1

    While attempting to lower the debris box into the dumpster the box hit a passing bus causing damage to the bus failure to safeguard all persons and property affected by construction operations., safeguard publi

    Jan 19, 2024

    Resolve
  • Class - 2

    Observed yellow beams stored on make-shift ulma reshores , loads inconsistent and not properly secured, debris stored against reshores. both conditions were observed at multiple locations. no approved ulma desi

    Jan 2, 2024 · Penalty $3,125

    Resolve
  • Class - 1

    Bc 3301.4 observed active operations consistent with stripping formwork, aerial crane operations, and horizontal netting weren't installed properly at the south corner, exp1 & 4, 3 & 4. also observed that deb

    Jan 2, 2024 · Penalty $5,000

    Resolve
  • Class - 2

    Miscellaneous violations. bc 3301.5 observed a worker performing patching concrete on the elevator shaft, and inside of the self-climbing platform. worker didn't have a proper means of egress. worker using a bu

    Jan 2, 2024 · Penalty $5,000

    Resolve
  • Class - 2

    Observed formwork materials ,debris, gasoline containers and diesel heaters throughout multiple floors, failure to provide adequate housekeeping create stripping and tripping hazardous condition for workers.

    Jan 2, 2024 · Penalty $3,125

    Resolve
  • Class - 2

    Miscellaneous violations. bc 3301.5 observed manlift being operated moving basket no caz and no person to help for proer direction, upon request to see user training certifiacte, none was provided. pre-shift an

    Jan 2, 2024 · Penalty $2,500

    Resolve
  • Class - 1

    Tower crane cn#795/22 cd#4589 was hoisting rebar when the rebar struck and broke the window of a neighboring building, safeguard public and property; provide proper safeguards

    Nov 10, 2023 · Penalty $10,000

    Resolve
  • Class - 1

    Tower crane cn#795/22 cd#4589 was hoisting rebar when the rebar struck and broke the window of a neighboring building, safeguard public and property; provide proper safeguards

    Nov 10, 2023

    Resolve

Complaints

No HPD complaints in our records

Complaint data is still being backfilled from NYC Open Data.

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Condominium (RC)
Year built
2022
Floors
26
Residential units
—
Building area
208,263 ft²
Lot area
16,067 ft²
Zoning
C5-3
Community board
105
Council district
6
Block / lot
1010 / 7509
Assessed value
$21,148,650
Landmark / historic district
No

Questions about 123 West 57th Street

Who owns 123 West 57th Street?

The owner of record in NYC Department of City Planning PLUTO data is 125 West 57th Street Property Owner, LLC.

Does 123 West 57th Street have violations?

NYC HPD has no housing violations on record for this property.

Is 123 West 57th Street rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was 123 West 57th Street built?

City records list 2022 as the year it was built.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.