roofy

143 West 40 Street

Manhattan, NY 10018BBL 1-00993-0005Map

Owner of record: 1435 Broadway LLC

143 West 40 Street is a garage / gas station built in 1964 in Manhattan, 10018. The owner of record is 1435 Broadway LLC. HPD has no housing violations on record for this property.

HPD violations
0
DOB violations
51
ECB violations
27
HPD complaints
1

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
No HPD violations

HPD has not cited this building.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 0

No HPD violations on record

DOB building violations · 51

  • Construction other optional

    Failure to maintain building in a code compliant manner as per section 28.301.1.of the nyc admin code.noted at time of inspection,observed at exp1,spalling and vertical crack on column.also at roof elevation on b ulkhead broken window.cracking,exposed masonry,missing and deteriorate d mortar and parapet.remedy:repair and/or replace

    Mar 10, 2026

    Dob violation - active
  • Hazardous condition (facade) facade required

    Cycle 9c unsafe report filed

    Jul 24, 2024

    Dob violation - active
  • No report and / or late filing (facade) facade required

    Failed to file fisp cycle 9c technical report by 2/21/2024

    Feb 22, 2024

    Dob violation - active
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Oct 4, 2023

    Dob violation - active
  • Construction other optional

    Overhead hazards&structrl defects pose danger 2.public.damgd.steel beams w.corrdd webs and/or flanges at the.bearing ends on multpl lvls retain reg nys design prof2file plans,drwgs4permant repair by 7/28/23 start wrk by 8/25/23

    May 24, 2023

    Dob violation - active
  • Construction other optional

    The occupied parking structure observed to be in the state of disrepair. cracks in concrete under 1st floor slab at cellar level, steel is fully deteriorated and missing in some areas, temporary shoring installed to support 1st floor.

    May 5, 2023

    Dob violation - active
  • Construction other optional

    C-construction other optional

    May 5, 2023

    Dob violation - active
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Sep 30, 2021

    Dob violation - resolved
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tst

    Sep 6, 2019

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tst

    Sep 6, 2019

    Dob violation - dismissed
Show 40 more ↓
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Aug 21, 2019

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Aug 21, 2019

    Dob violation - resolved
  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    May 2, 2019

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst

    Jan 26, 2018

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst

    Jan 26, 2018

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Aug 29, 2017

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Aug 29, 2017

    Dob violation - resolved
  • Construction other optional

    Business sign marguee approx. 4'h x 10'w x 5' long 12' high from curb level. wording "$.99 fresh pizza" this marguee tied with metal stripe about 8' long anchored into building wall without a permit

    Jan 20, 2017

    Vpw*-violation unserved ecb-work without permit-dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2015 cat 1 insp/tst

    Jan 3, 2017

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2015 cat 1 insp/tst

    Jan 3, 2017

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2014 cat 1 insp/tst

    Nov 14, 2016

    Dob violation - dismissed
  • Elevator affirmation of correction elevatorrequired

    Vio issued to elevator - fail to correct defects on 2014 cat 1 insp/tst

    Nov 14, 2016

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Aug 10, 2016

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Aug 10, 2016

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Aug 27, 2015

    Dob violation - resolved
  • No report and / or late filing (facade) facade required

    Failed to file fisp cycle 7c technical report by 02/21/2013

    Dec 31, 2013

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Aug 24, 2011

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Aug 24, 2011

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Aug 14, 2008

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Aug 14, 2008

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 14, 2007

    Dob violation - resolved
  • Elevator elevatorrequired

    02

    Dec 14, 2007

    Dob violation - resolved
  • Facade facade optional

    Ll1198-local law 11/98 - facade facade optional

    Nov 30, 2007

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jan 16, 2007

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jan 16, 2007

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jul 13, 2006

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Mar 1, 2006

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Mar 1, 2006

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Mar 11, 2005

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Mar 11, 2005

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    May 20, 2004

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    May 20, 2004

    Dob violation - resolved
  • Facade facade required

    L1198-local law 11/98 - facade facade required

    Aug 8, 2002

    Dob violation - dismissed
  • Elevator elevatorrequired

    1f5201

    Jun 20, 2002

    Dob violation - resolved
  • Elevator elevatorrequired

    1f5202

    Jun 20, 2002

    Dob violation - resolved
  • Elevator elevatorrequired

    1f5201

    May 11, 2001

    Dob violation - resolved
  • Elevator elevatorrequired

    1f5202

    May 11, 2001

    Dob violation - resolved
  • Elevator elevatorrequired

    1f5201

    Aug 23, 2000

    Dob violation - resolved
  • Elevator elevatorrequired

    1f5201

    Jan 23, 1999

    Dob violation - resolved
  • Elevator elevatorrequired

    1f5202

    Jan 23, 1999

    Dob violation - resolved

ECB violations · 27

  • Class - 2

    At time of inspection observed that no steel props supporting 1st floor slab in cellar level (slab rectified) however failure to submit a certificate of correction of violation #39085656l issued on 05-05-2023 f

    Jun 25, 2026 · Penalty $1,280

    Active
  • Class - 1

    Failure to submit a certificate of correction of violation #37025591m issued on 10-11-2023 for unlawful acts. failure to comply with commissioner's order (no engineer's report n2 on dob file), comply with commi

    Jun 25, 2026 · Penalty $2,530

    Active
  • Class - 2

    Failure to file acceptable amended cycle 8c and 9c report indicating correction of unsafe conditions described in initial facades report required by 28-302.5 for control #903017. agg1: prior nov 37026383m under

    Apr 20, 2026 · Penalty $10,000

    Active
  • Class - 1

    Ac28-323.8 and rcny 103-13 failure to secure public safety and/or makethe buildings structure and appurtenances confirm to the provisions ofthe administrative code after unsafe notifaction filed q.p.s.i. at the

    Feb 12, 2024 · Penalty $2,500

    Resolve
  • Class - 1

    28-323.1 failure to maintain parking structure in safe condition. as noted at time of inspection on a parking structure consisting of 9 levels and 1 bg. observed conditions: cracked and spalling concrete ceilin

    Feb 12, 2024 · Penalty $2,500

    Resolve
  • Class - 2

    Failure to file acceptable amended cycle 8c report indicating correction of unsafe conditions described in initial facades report required by 28-302.5 for control#803017.rem:file acceptable report.

    Jan 16, 2024 · Penalty $1,250

    Active
  • Class - 2

    Pedestrian protection does not meet code specifications sws erected at exp 1 in unsafe condition 3307.6.5.1, 16 missing bolt caps on screws creates hazard to the public of sharp edges 3307.6.5.6, also missing h

    Nov 20, 2023 · Penalty $2,430

    Resolve
  • Class - 1

    Failure to comply with the commissioner's order in dob violation vio23-01318,dated 5/5/2023.respondent was required to submit an engineer's report concerning structurally deficient conditions.as of 10/11/2023,a

    Oct 11, 2023 · Penalty $2,500

    Active
  • Class - 1

    Cellar level structural steel supporting first floor concrete slab, completely corroded and fully missing in 3 area. light corrosion on structural steel for all upper floors engineer's remove part of ceiling to

    May 5, 2023 · Penalty $1,250

    Active
  • Class - 2

    1st floor of parking garage walls put up to create pizza shop., obtain all permits

    May 5, 2023

    Resolve
Show 17 more ↓
  • Class - 2

    On all floors cellar to roof drains not working or broken causing flooding on some levels by stairs, also causing damage to ceilings and parts of ceilings falling., repair and/or replace

    May 5, 2023 · Penalty $625

    Active
  • Class - 2

    No power to emergency light & light on the right side of building (exp2) electrical line on that side of building is out cellar to 9th floor., provide adequate power for emergency exit lighting

    May 5, 2023 · Penalty $625

    Resolve
  • Class - 2

    1st floor pizzeria made no new cofo for change of use, building listed as g9-garage/gas stat'n on bis (g9 miscellaneous garage), discontinue illegal occupancy or amend c of o

    May 5, 2023

    Resolve
  • Class - 2

    Cellar level temporary shoring put up to support 1st floor slab in 3 areas no permits on file for emergency shoring or design drawings for shoring installed., obtain all permits

    May 5, 2023 · Penalty $1,250

    Resolve
  • Class - 2

    Failure to submit an acceptable required cycle 8c report of critical examination documenting condition of exterior wall & appurtenances required by 28-302.4 for control#803017. remedy: submit acceptable require

    Feb 13, 2020 · Penalty $1,250

    Active
  • Class - 2

    Failure to maintain building in code compliant manner in that at various levels,plaster ceilings defective at various locations.sections cracked, loose, missing. rmdy:make safe immediately,make all necessary re

    May 8, 2013 · Penalty $250

    Resolve
  • Class - 2

    Failure to maintain bldg, noted spalling concrete ceiling on multiple levels. also defective stair treads on staircase leading to basement (west side) and tread on 2-3 flr (west side). remedy: maintain bldg.

    Dec 8, 2011

    Resolve
  • Class - 1

    Failure to provide unobstructed passageway. noted on multiple levels, cars blocking passageway of staircase. remedy: remove obstructions.

    Dec 8, 2011 · Penalty $1,600

    Resolve
  • Class - 3

    98bb05,99m05. 98-expired 5yr test perform and file catergory 5 yr test99m-perform and file category one test.

    Oct 7, 2009 · Penalty $200

    Resolve
  • Class - 1

    16l1.03b7.100l11.52h11 16l01 observed lobby gate has too much clearance of more than 6 inches c.u adjust gate to proper adjustment at lobby door 030307 2 large hole in cab covered by signs provide proper cover

    Oct 5, 2009 · Penalty $1,000

    Resolve
  • Hazardous

    Failure to maintain exterior bldg wall. noted on the south elevation,cracked, disintegrating w/ multiple opening @ plaster soffits overlooking public sidewalk overlooking public sidewalk. remedy:take precaution

    Jun 12, 2007 · Penalty $800

    Resolve
  • Hazardous

    Exit passageway total obstruction note: parked cars are parked in locations that are causing total obstruction of egress to fire stairs throughout bldg on both stair cases all floors remedy: remove obstruction

    Jul 29, 2004 · Penalty $1,200

    Resolve
  • Hazardous

    Exit passageway total obstruction: note cars are parked in postions throughout garage, at all floors & @ both stairwells, in a manner that is causing total obstruction of egress to fire stairs-on both stairwell

    Jul 29, 2004 · Penalty $480

    Resolve
  • Hazardous

    Exit passageway total obstruction:note parked cars in front of west and east stair wells at exits on each floor are obstructed making egressthrough stairwells totally obstructed.remedy:remove obstruction

    Mar 16, 2004 · Penalty $480

    Resolve
  • Non-hazardous

    Failure to maintain building. defect noted: at all floors spalling plaster at ceiling level (at various locations) note: at 6th floor a piece of ceiling was missing. remedy: maintain building.

    Nov 19, 2003 · Penalty $180

    Resolve
  • Non-hazardous

    02l 02 repair defective alarm system in car

    Jun 4, 1999

    Resolve
  • Non-hazardous

    05j, reinstall 1st floor as door hit by automobile

    Jan 16, 1991

    Resolve

Complaints

  • Nonconst

    Vermin

    Dec 27, 2008 · Apt 7H

    Close

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Garage / gas station (G9)
Year built
1964
Floors
9
Residential units
—
Building area
43,571 ft²
Lot area
5,155 ft²
Zoning
C5-3
Community board
105
Council district
3
Block / lot
993 / 5
Assessed value
$2,764,350
Landmark / historic district
No

Questions about 143 West 40 Street

Who owns 143 West 40 Street?

The owner of record in NYC Department of City Planning PLUTO data is 1435 Broadway LLC.

Does 143 West 40 Street have violations?

NYC HPD has no housing violations on record for this property.

Is 143 West 40 Street rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was 143 West 40 Street built?

City records list 1964 as the year it was built.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.