2 Park Avenue
Manhattan, NY 10016BBL 1-00862-0029Map
Owner of record: Hadson 2 Park Ave LLC
2 Park Avenue is an office building built in 1928 in Manhattan, 10016. The owner of record is Hadson 2 Park Ave LLC. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 257
- ECB violations
- 58
- HPD complaints
- 2
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 257
- Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Mar 6, 2024
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Feb 21, 2024
Dob violation - dismissed - Construction other optional
Emergency work order parking structure consisting of 1 level below ramp /driveway spalling concrete/exposed rebar from the slab soffit & exposed steel beam @several loc.causing immed.haz pub.& traffic.remedy retain rdp immed.and supervise & direct install.of safety measures prov.shoring &barricades under full time supervision daily prog.report
Dec 19, 2023
Dob violation - dismissed - Failure to post energy grade/score none
Failure to display energy efficiency score and energy efficiency grade as per adcode sec. 28-309.12.3
Dec 1, 2023
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tst
Sep 6, 2019
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tst
Sep 6, 2019
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tst
Sep 6, 2019
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tst
Sep 6, 2019
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tst
Sep 6, 2019
Dob violation - dismissed - Sprinkler none
Failed to file final sprinkler report by july 1, 2019
Sep 3, 2019
Dob violation - dismissed
Show 40 more ↓
- Elevator elevatorrequired
E-elevator elevatorrequired
Aug 1, 2019
Dob violation - resolved - Elevator annual inspection / test elevatorrequired
Violation issued to elevator - failure to file category 1 2017 inspection/test
Apr 5, 2019
Dob violation - dismissed - Elevator annual inspection / test elevatorrequired
Violation issued to elevator - failure to file category 1 2017 inspection/test
Apr 5, 2019
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Oct 16, 2018
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Oct 10, 2018
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Oct 10, 2018
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Oct 10, 2018
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Oct 10, 2018
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Oct 10, 2018
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Oct 9, 2018
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Oct 9, 2018
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Oct 9, 2018
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Oct 9, 2018
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Oct 9, 2018
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Oct 9, 2018
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Oct 9, 2018
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Oct 9, 2018
Dob violation - resolved - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst
Jan 26, 2018
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst
Jan 26, 2018
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst
Jan 26, 2018
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst
Jan 26, 2018
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst
Jan 26, 2018
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst
Jan 26, 2018
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jan 10, 2018
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jan 10, 2018
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jan 10, 2018
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Oct 18, 2017
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Oct 18, 2017
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Aug 23, 2017
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Aug 23, 2017
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Aug 23, 2017
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Aug 22, 2017
Dob violation - resolved - Construction other optional
C-construction other optional
Jul 20, 2017
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jun 14, 2017
Dob violation - dismissed - Construction other optional
Electrical wires being installed in conduit secured underneath sidewal k shed in front of 2 park ave from the front entrance to corner of 33r d street and park ave. installation of new outlet boxes and gfct outle ts. the app m369202 does not cover new work
Mar 24, 2017
Vpw*-violation unserved ecb-work without permit-dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2015 cat 1 insp/tst
Jan 3, 2017
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2015 cat 1 insp/tst
Jan 3, 2017
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2015 cat 1 insp/tst
Jan 3, 2017
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2015 cat 1 insp/tst
Jan 3, 2017
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2015 cat 1 insp/tst
Jan 3, 2017
Dob violation - dismissed
ECB violations · 58
- Class - 1
Unlawful acts.failure to comply with commissioner's order.note:at the time of inspection observed respondent failure to comply with previousviolation#35675592x and dob violation#121923l210502mk dated 12/19/2023
Mar 14, 2024 · Penalty $2,500
Resolve - Class - 1
28-323.8 and rcny 103-13(5) failure to secure public safety and/or make the buildings structure and appurtenances conform to the previous ofthe admin code after unsafe notification filed u.n.p.s.-m0000085 dated
Dec 19, 2023 · Penalty $2,500
Resolve - Class - 1
28-323.1 failure to maintain parking structure in safe condition. note:-observed on an occupied parking structure consisting of 1 level below parking structure ramp/drive way spalling concrete/exposed re-bar/st
Dec 19, 2023 · Penalty $2,500
Resolve - Class - 2
Failure to institute & maintain safety measures. note: at time of my inspection in response to an incident where 1 worker fell off from baker scaffold injured his leg & was taken to hospital. inspection reveals
Feb 16, 2021 · Penalty $5,000
Resolve - Class - 1
Sec. 3314.4.5.8 failure to have scaffold training certification. note:at time of my inspection of 29 sty bldg under interior renovation on 19th floor in response to an incident where 1 worker fell off from a ba
Feb 16, 2021 · Penalty $2,500
Resolve - Class - 2
Sec. 27-929.1 ac 27-929.1 failure to complete the installation of a full system of automatic sprinklers & file a final sprinkler report prepared by a registered design professional by 7/1/19,in an office bldg
Mar 30, 2020 · Penalty $3,125
Resolve - Class - 2
Sec. a.c.27-929.1,failure to complete the installation of a full system of automatic sprinklers & file a final sprinkler report prepared by a registered design professional by 7/1/19,in an office bldg 100 feet
Nov 15, 2019 · Penalty $1,280
Resolve - Class - 2
98.bb.05=current five year tag on car governor hat expired.last listing is for 8/2013.
Mar 15, 2019
Resolve - Class - 2
52b14,29h11. (52b)hoist cables insufficient- shorten. (29h)door operator belt worn- replace.
Jun 21, 2018 · Penalty $625
Resolve - Class - 2
52b14. hoist cables, insufficient, shorten.
Jun 21, 2018 · Penalty $625
Resolve
Show 40 more ↓
- Class - 1
Unlawful acts failure to comply w/an order of the commissioner. in november 17,2017, an administrative code violation was issued to the respondent. the respondent failed to comply with nyc #28-201.1 (ecb)
Jan 24, 2018 · Penalty $800
Resolve - Class - 1
Unlowful acts. failure to comply with an order of the commissioner. in7/24/17 2 electrical vios was issued to the respondent. the respondentfailed to comply with (nyc) electrical code # 110.2(a), 300(ecb's) # 3
Nov 17, 2017 · Penalty $800
Resolve - Class - 2
3310.4 site safety monitoring @ time of inspection of work on roof b ulkhead & penthouse fl no site safety monitoring plan/safety manager or coordinator on a site that has a (fafilty) on roof.stop all work rel
Aug 2, 2017 · Penalty $800
Resolve - Class - 1
Sec. 300.3(b) misc violation of the electrical code technical standards. no raceway provided for live exposed wires on roof. remedy: comply w/ec code.
Jul 24, 2017 · Penalty $400
Resolve - Class - 2
Fail to provide effective continuity for metal raceways/enclosures/cable armor. raceway for feeders conductors are not continuous,no continuity provided to around electrial system. remedy: provide effective ele
Jul 24, 2017 · Penalty $600
Resolve - Class - 2
Failure to secure/support raceways/cable assemblies/boxes/cabinets/fittings. on 7/24/17 i observed on roof disconnect boxes & electrical raceways are not properly secure. remedy: secure/support per ec.
Jul 24, 2017 · Penalty $400
Resolve - Class - 1
Unapproved/unsafe/unsuitable electrical equipment apparatus,materials,devices,appliances or wiring in use. defective wiring in use due to fray insulation on feeders conductors for on roof. exhaust fan.
Jul 24, 2017
Resolve - Class - 1
Failure to maintain:housekeeping note:roof operation in progress evevator bulkhead there is equiptment & debris on the roof scaffold equiptment,(foam) isolation,metal track the tools (scattered) across roof-cre
Jul 20, 2017 · Penalty $2,400
Resolve - Class - 1
Fire code-general noted:on roof level observed 2 compreessed containers laying on root among assorted material.they were not i use not stored upright or in a secure lovn-cauing a hazard on site.rem:comply w/cod
Jul 20, 2017 · Penalty $2,400
Resolve - Class - 1
Failure to safeguard all persons & property affected by const ops.note:bulkhead exterior extension in progress @roof level worker on roof installing track to bulkhead in between bulkhead & mechanical roof equip
Jul 20, 2017 · Penalty $25,000
Resolve - Class - 1
Electric work w/o permit. i observed electrical wires being installed in conduit secured underneath sidewalk shed in front of 2 park av fromthe front entrance to corner of 33rd st and ark av. i also observed
Mar 24, 2017 · Penalty $800
Resolve - Class - 2
59j15,58b07,05b07. provide brake maintenance tags as per a17.1 2003 and appendix k3 8.6.4.6. 05-door zone restrictor not working.
May 18, 2016 · Penalty $500
Resolve - Class - 1
05b07. door zone restrictor rendered inoperable, repair immediately.
May 18, 2016 · Penalty $1,000
Resolve - Class - 2
53i11,100m07. 53i11-cease use device ip3270 due to borkern governor rope, () replace and file test; 100m07-missing mcp provide.
Sep 17, 2013 · Penalty $500
Resolve - Class - 2
97x10 repair return to service so a full insp can be conducted by dob
Dec 18, 2010
Resolve - Class - 2
16p13.54h11.16p13 sealed off front hatch doors on fls 5.6.7.8.9.10.12.17. file & obtai permit & call for inspection
Dec 23, 2008 · Penalty $800
Resolve - Non-hazardous
51i11 51 replace damaged hoist ropes
Mar 12, 2008 · Penalty $350
Resolve - Non-hazardous
51h11. 51 hoist ropes have multiple crown breaks replace hoist ropes
Mar 12, 2008 · Penalty $350
Resolve - Non-hazardous
51o02. 51 clean hoist ropes for a proper inspection
Mar 12, 2008
Resolve - Non-hazardous
51o02.51-clean & monitor ropes as per code.
Jan 23, 2008
Resolve - Non-hazardous
09b07,66m07 09-provide permanent flooring in cuben closure.66-m-provide pit signage on door
Jul 24, 2006
Resolve - Non-hazardous
Failure to maintain exterior bldg wall noted:section of stone work off17 story bldg found on sidewalk section missing approx:1 square foot stone work from between 1st & 2nd fl of bldg
Jul 19, 2006 · Penalty $2,500
Resolve - Hazardous
Sidewalk shed does not meet bldg code specifications noted: a.no side deck enclosure b.shed not extended 20ft for bldg more than 100ft in height on east 32st & 33st sides.remedy:conform shed to bldg code specif
Jul 5, 2006 · Penalty $10,000
Resolve - Non-hazardous
84b10 fire recall service phase 1&2 need to be updated to code.
Jun 28, 2006 · Penalty $180
Resolve - Non-hazardous
84b10 84-b-10 fire recall service phase 1&2 needs to be updated to code.
Jun 28, 2006 · Penalty $180
Resolve - Non-hazardous
84b10 84-b-10 phase 1&11 fire recall service need to updated to code.
Jun 28, 2006 · Penalty $180
Resolve - Non-hazardous
84b07 84-b-07 fire return insufficient bring up to code.
Jun 20, 2006 · Penalty $180
Resolve - Non-hazardous
84b07 84-b-07 fine return insufficient bring up to code.
Jun 20, 2006 · Penalty $180
Resolve - Non-hazardous
84b07 84-b-07 fire return insufficient bring up to code.
Jun 20, 2006 · Penalty $180
Resolve - Non-hazardous
84-b-10 fire recall system does not work properly make necessary repairs.
May 23, 2006 · Penalty $180
Resolve - Non-hazardous
84-b-10 fire recall system does not work properly make necessary repairs.
May 23, 2006 · Penalty $180
Resolve - Non-hazardous
84-b-10 fire recall systems does not work properly make necessary repairs.
May 23, 2006 · Penalty $180
Resolve - Non-hazardous
84b10. 84-fire recall system does not work properly make necessary repair.
May 22, 2006 · Penalty $180
Resolve - Non-hazardous
Elevators
May 22, 2006
Resolve - Non-hazardous
84-b-10 fire service does not work properly, make necessary repairs.
May 22, 2006 · Penalty $180
Resolve - Non-hazardous
Sidewalk shed does not meet bldg. code spec. defect is: shed not extended 20 ft for bldg. more than 100 in height on e 32 st & e 33 st sides. remedy: conform shed to bldg. code spec.
Feb 22, 2006 · Penalty $2,000
Resolve - Non-hazardous
81bb05
Dec 16, 2002
Resolve - Non-hazardous
Failure to provide approved plans at premises at time of inspection.alt 102134209 remedy:provide approved plans at premises.
May 3, 2001
Resolve - Non-hazardous
22d06,11b07,33b07.22-top emergency exit covers properly secure.11-provide car lighting.33-lighting in secondary insufficient provide.18-inter lock covers missing provide.74-remove wooden door in basement.
Nov 15, 2000
Resolve - Non-hazardous
73##,22d06.73-return to service for full inspection.22-top emergency exit cover secure.
Nov 15, 2000 · Penalty $350
Resolve
Complaints
- Unsanitary condition
Garbage/recycling storage
Jun 19, 2025 · Apt BLDG
Close - Paint/plaster
Ceiling
Oct 31, 2023 · Apt 9
Close
Sales history
No recorded sales in our data
Building details
- Building type
- Office building (O4)
- Year built
- 1928
- Floors
- 25
- Residential units
- —
- Building area
- 852,731 ft²
- Lot area
- 40,487 ft²
- Zoning
- C5-2
- Community board
- 105
- Council district
- 4
- Block / lot
- 862 / 29
- Assessed value
- $119,771,100
- Landmark / historic district
- INDIVIDUAL LANDMARK
Questions about 2 Park Avenue
Who owns 2 Park Avenue?
The owner of record in NYC Department of City Planning PLUTO data is Hadson 2 Park Ave LLC.
Does 2 Park Avenue have violations?
NYC HPD has no housing violations on record for this property.
Is 2 Park Avenue rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 2 Park Avenue built?
City records list 1928 as the year it was built.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.