roofy

27 East 21 Street

Manhattan, NY 10010BBL 1-00850-0022Map

Owner of record: 27 East Coll LLC

27 East 21 Street is an office building built in 1903 in Manhattan, 10010. The owner of record is 27 East Coll LLC. HPD has no housing violations on record for this property.

HPD violations
0
DOB violations
61
ECB violations
18
HPD complaints
0

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
No HPD violations

HPD has not cited this building.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 0

No HPD violations on record

DOB building violations · 61

  • Low pressure boiler boiler required

    Violation issued-failure to file 2024 external low pressure inspection

    Nov 14, 2025

    Dob violation - active
  • Low pressure boiler boiler required

    Violation issued-failure to file 2023 external low pressure inspection

    Sep 23, 2024

    Dob violation - active
  • Low pressure boiler boiler required

    Violation issued-failure to file 2022 external low pressure inspection

    Apr 25, 2023

    Dob violation - active
  • No report and / or late filing (facade) facade required

    Failed to file fisp cycle 9b technical report by 2/21/2023

    Feb 22, 2023

    Dob violation - active
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Oct 14, 2020

    Dob violation - active
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Sep 2, 2020

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Aug 26, 2020

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Aug 26, 2020

    Dob violation - resolved
  • Sprinkler none

    Failed to file final sprinkler report by july 1, 2019

    Sep 3, 2019

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jul 23, 2019

    Dob violation - resolved
Show 40 more ↓
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jul 23, 2019

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Aug 14, 2017

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Aug 14, 2017

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jul 18, 2016

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jul 18, 2016

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Aug 18, 2015

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Aug 18, 2015

    Dob violation - resolved
  • Elevator annual inspection / test elevatorrequired

    Violation issued to elevator-failure to file category 1 2013 inspection/test

    Oct 31, 2014

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Aug 8, 2014

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Aug 8, 2014

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Aug 8, 2014

    Dob violation - active
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jun 10, 2013

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jun 10, 2013

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Aug 29, 2012

    Dob violation - resolved
  • Elevator annual inspection / test elevatorrequired

    Violation issued to elevator-failure to file category 1 2010 inspection/test

    Dec 13, 2011

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 22, 2010

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Dec 22, 2010

    Dob violation - resolved
  • Elevator annual inspection / test elevatorrequired

    Vcat1-elevator annual inspection / test elevatorrequired

    Oct 8, 2010

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Aug 19, 2009

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Aug 19, 2009

    Dob violation - resolved
  • Elevator elevatoroptional

    Ll1081-local law 10/81 - elevator elevatoroptional

    Feb 27, 2009

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jun 4, 2008

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Jun 4, 2008

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Feb 28, 2008

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Feb 28, 2008

    Dob violation - resolved
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jan 3, 2008

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Apr 12, 2007

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Apr 12, 2007

    Dob violation - resolved
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jan 19, 2007

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jan 6, 2006

    Dob violation - dismissed
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Jan 31, 2005

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Nov 16, 2004

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Nov 16, 2004

    Dob violation - resolved
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Feb 13, 2004

    Dob violation - dismissed
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Sep 23, 2003

    Dob violation - resolved
  • Elevator elevatorrequired

    E-elevator elevatorrequired

    Sep 23, 2003

    Dob violation - resolved
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Mar 19, 2003

    Dob violation - dismissed
  • Facade facade required

    L1198-local law 11/98 - facade facade required

    Aug 8, 2002

    Dob violation - active
  • Boilers boiler required

    Ll6291-local law 62/91 - boilers boiler required

    Mar 26, 2002

    Dob violation - dismissed
  • Elevator elevatorrequired

    1p4267

    Jun 12, 2001

    Dob violation - resolved

ECB violations · 18

  • Class - 2

    Bc 3307.6.4.8 at time of inspection i observed sidewalk shed installed on exposure #1 with inoperable light bulbs at underside the shed to bring illumination failure to provide lighting creates unsafe and mugg

    Nov 25, 2024 · Penalty $2,400

    Resolve
  • Class - 1

    Failure to provide sidewalk shed where required as noted:at time of inspection i observed on exposure#1 south elevation:lacks in decorative stone at 1st floor spandrel at several locations exposure#4 east eleva

    Oct 1, 2020 · Penalty $2,500

    Resolve
  • Class - 2

    Failure to comply with commissioner's order to file a certificate of correction with the department of building as noted:at time of inspection respondent did not comply to previous violation#35538752p.rem:repai

    Oct 1, 2020 · Penalty $3,125

    Resolve
  • Class - 2

    Failure to comply with commissioner's order to file a certificate of correction with the department of buildings.at time of inspection respondent did not comply with previous violation#35538435l dated 05/14/202

    Sep 4, 2020

    Resolve
  • Class - 3

    Failure to post building exterior wall condition certification as required under 1rcny 103-04(f)at time of inspection the building exterior wall condition certification was not posted.rem:post building exterior

    Sep 4, 2020 · Penalty $250

    Resolve
  • Class - 1

    Failure to repair swarmp conditions in a timely manner.note:on 07/16/2020,no evidence of deteriorated magnary on the east elevation exposure4 repairs was found.qewi,debris acar identified these swarmp condition

    Jul 16, 2020 · Penalty $25,000

    Active
  • Class - 2

    Failure to comply with commissioner's order to file a certificate of correction with the department of buildings.note:at the time of inspection respondent did not comply with previous violation#35538435l issued

    Jul 16, 2020

    Resolve
  • Class - 1

    Miscellaneous violation.noted:on 05/14/2020,no evidence of "deteriorated masonary on the east elevation(exposure# 4)repairs was found.qewi,baris acar identified these swarmp conditions on his report on 02/17/20

    May 14, 2020

    Resolve
  • Class - 2

    Sec. a.c.27-929.1,failure to complete the installation of a full system of automatic sprinklers & file a final sprinkler report prepared by a registered design professional by 7/1/19,in an office bldg 100 feet

    Nov 15, 2019

    Resolve
  • Non-hazardous

    24l10,25d06,36o02,39o02,55y10,41l11,66m07,41m15.24l10-6 & 9fl when elevator passes each fl(both # light up)25d06-properly secure emergency exit cover.39o02-properly clean machine room free of oil & grease.55y10

    Feb 28, 2007

    Resolve
Show 8 more ↓
  • Non-hazardous

    Failure to submit a fifth round technical report periodic inspection of exterior walls and appurtenances as required by local law 11 of 1998and the dept of bldg rules and regulations remedy file the required re

    Oct 17, 2003 · Penalty $700

    Resolve
  • Unknown

    37g,22d,60b,73l,15r.37-remove jumper on controller 22 secure top exit cover 60 provide proper counterweight clearence 73 eliminate excessive noise and excessive vibration on 1p4267 15 provide access keyhole in

    Feb 16, 1996

    Resolve
  • Unknown

    02i,46h,37g.02-secure alarm system under car 46-renew hoist ropes 37-remove jumper on controller.

    Feb 16, 1996

    Resolve
  • Non-hazardous

    46t,49.

    Jan 15, 1993

    Resolve
  • Non-hazardous

    46t,49t.

    Jan 15, 1993

    Resolve
  • Non-hazardous

    46t,49t,47h. 46,49 reshackle and properly tag. 47 governor cable worn,repalce.

    Oct 23, 1991 · Penalty $1,000

    Resolve
  • Non-hazardous

    73x,46t,49t

    Mar 27, 1991 · Penalty $1,000

    Resolve
  • Non-hazardous

    46t,49t,46k,47h,74m 74)provide proper clearance between the cut+the buffer.

    Mar 27, 1991 · Penalty $1,000

    Resolve

Complaints

No HPD complaints in our records

Complaint data is still being backfilled from NYC Open Data.

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Office building (O6)
Year built
1903
Floors
10
Residential units
—
Building area
20,358 ft²
Lot area
2,469 ft²
Zoning
M1-5M
Community board
105
Council district
2
Block / lot
850 / 22
Assessed value
$1,706,400
Landmark / historic district
Ladies' Mile Historic District

Questions about 27 East 21 Street

Who owns 27 East 21 Street?

The owner of record in NYC Department of City Planning PLUTO data is 27 East Coll LLC.

Does 27 East 21 Street have violations?

NYC HPD has no housing violations on record for this property.

Is 27 East 21 Street rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was 27 East 21 Street built?

City records list 1903 as the year it was built.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.