roofy

132 West 28 Street

Manhattan, NY 10001BBL 1-00803-0058Map

Owner of record: 28th Steet Properties LLC

132 West 28 Street is a hotel built in 2019 in Manhattan, 10001. The owner of record is 28th Steet Properties LLC. HPD has recorded 39 housing violations here, most recently on October 26, 2016.

HPD violations
39
DOB violations
13
ECB violations
72
HPD complaints
89

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
Last violation Oct 26, 2016

Date of the most recent HPD inspection that found a problem.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 39

  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Oct 26, 2016

    Closed — Violation dismissed
  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Oct 2, 2015

    Closed — Violation dismissed
  • B

    Properly repair the broken or defective window counter balance upper sash in the 1st room from north located at apt 5w, 5th story, 1st apartment from south at west

    Sep 27, 2010 · Apt 5W

    Closed — Violation closed
  • B

    Repair the leaky and/or defective faucets at tub faucet in the bathroom located at apt 5w, 5th story, 1st apartment from east at south

    Sep 27, 2010 · Apt 5W

    Closed — Violation closed
  • B

    Properly repair with similar material the broken or defective fire retardant material at ceiling, east and west walls at public hall, 1st story

    Sep 27, 2010

    Closed — Violation closed
  • A

    Paint with light colored paint to the satisfaction of this department ceiling , east and west walls at public hall, 1st story

    Sep 27, 2010

    Closed — Violation closed
  • B

    § 62, 187, 231 m/d law and dept. rules and regs. safeguard egress by providing iron guard rails or parapet walls 3 ft 6 in high and extending a minimum of 4 ft 0 in beyond either side of bulkhead/scuttle opening at roof ''south & west parapet wall 26 inches hight only, attached goose neck to rear south fire escape.''

    Aug 2, 2010

    Closed — Violation closed
  • A

    § 53, 187, 231 m/d law and department rules and regulations. provide a shoe properly secured to bottom of string of dropladder front noth stack fire escape

    Oct 9, 2008

    Closed — Violation closed
  • C

    Provide ready access to buildings heating system side walk hatch door with padlock .door to heating system locked

    Oct 9, 2008

    Closed — Violation closed
  • B

    Repair the leaky and/or defective faucets at tub in the bathroom located at apt 3e, 3rd story, 1st apartment from north at east

    Mar 26, 2007 · Apt 3E

    Closed — Violation closed
Show 29 more ↓
  • C

    Post notice, in form approved by the department, stating the name and location of the person designated by the owner to have key to buildings heating system , at public hall, 1st story

    Jan 10, 2006

    Closed — Violation closed
  • B

    D26-13.03 adm code abate the nuisance consisting of vermin roaches thru out apt 2e 2 sty east. , section '' ''

    Jun 5, 1991 · Apt 2E

    Closed — Violation closed
  • B

    Arrange and make self-closing the doors entrance 5 sty west apt 5w. , section '' ''

    Jun 5, 1991 · Apt 5W

    Closed — Violation closed
  • B

    Repair or replace the smoke detector missing 2 sty east apt 2e choi. located at apt 2e

    Jun 5, 1991 · Apt 2E

    Closed — Violation closed
  • B

    Arrange and make self-closing the doors entrance 4 sty west apt 4w. located at apt 4w

    Jun 5, 1991 · Apt 4W

    Closed — Violation closed
  • B

    Properly repair with similar material the broken or defective fire retarding walls & ceiling of boiler room at cellar.

    May 31, 1991

    Closed — Violation closed
  • B

    Remove all encumbrances consisting of bike & box 2 sty public hall.

    May 31, 1991

    Closed — Violation closed
  • B

    Repair the broken or defective plastered surfaces and paint in a uniform color ceiling 2 from front room 3 sty east apt 3e. located at apt 3e

    May 31, 1991 · Apt 3E

    Closed — Violation closed
  • B

    M/d law abate the nuisance consisting of exposed electrical wires walls & ceiling rear room 3 sty east apt 3e. located at apt 3e

    May 31, 1991 · Apt 3E

    Closed — Violation closed
  • B

    Remove the accumulation of refuse and/or rubbish and maintain in a clean condition the bricks tar cans etc on roof.

    May 31, 1991

    Closed — Violation closed
  • B

    Properly repair with similar material the broken or defective fire retarding enclosure of flue tank in cellar.

    May 31, 1991

    Closed — Violation closed
  • B

    Replace with new the missing junction box cover of ceiling above rear fule tank in cellar.

    May 31, 1991

    Closed — Violation closed
  • B

    Properly repair with similar material the broken or defective fire reatrding ceiling throughout cellar.

    May 31, 1991

    Closed — Violation closed
  • B

    Remove the accumulation of refuse and/or rubbish and maintain in a clean condition the cement debris etc rear yard & rear areaway.

    May 31, 1991

    Closed — Violation closed
  • B

    Replace with new the missing metal fence rail of rear areaway.

    May 31, 1991

    Closed — Violation closed
  • B

    Fire escape defective. adjust the dropladder so that it will slide easily in the guide rods 1 sty balcony rear fire escape.

    May 31, 1991

    Closed — Violation closed
  • B

    Properly repair with similar material the broken or defective cement at steps from cellar to rear yard.

    May 31, 1991

    Closed — Violation closed
  • B

    M/d law abate the nuisance consisting of exterior door handle of bulkhead entrance to roof.

    May 31, 1991

    Closed — Violation closed
  • B

    Arrange and make self-closing the doors entrance to boiler room in cellar.

    May 31, 1991

    Closed — Violation closed
  • B

    M/d law abate the nuisance consisting of bx cable 4 sty front east apt 4e kitchen ceiling. located at apt 4e

    May 16, 1988 · Apt 4E

    Closed — Violation closed
  • B

    Arrange and make self-closing the doors 4 sty front east apt 4e entrance.

    May 16, 1988

    Closed — Violation closed
  • B

    Abate the nuisance consisting of vermin mice 4 sty front east apt 4e kitchen. located at apt 4e

    May 16, 1988 · Apt 4E

    Closed — Violation closed
  • B

    Properly secure the loose sink 4 sty front east apt 4e kitchen. located at apt 4e

    May 16, 1988 · Apt 4E

    Closed — Violation closed
  • B

    Provide an approved and operational smoke detecting device, installed in accordance with department of buildings rules and regulations missing 4 sty front east apt 4e. located at apt 4e

    May 16, 1988 · Apt 4E

    Closed — Violation closed
  • B

    Repair the broken or defective plastered surfaces and paint in a uniform color wall and ceiling 4 sty front east apt 4e front room. located at apt 4e

    May 16, 1988 · Apt 4E

    Closed — Violation closed
  • B

    Abate the nuisance consisting of vermin roaches 4 sty front east apt 4e kitchen. located at apt 4e

    May 16, 1988 · Apt 4E

    Closed — Violation closed
  • B

    M/d law abate the nuisance consisting of key operated double cylinder lock installed entrance 4th sty east apt 4e door. , section '' ''

    Dec 9, 1987 · Apt 4E

    Closed — Violation closed
  • B

    Provide an approved and operational smoke detecting device, installed in accordance with department of buildings rules and regulations 4 sty east apt 4e. , section '' ''

    Nov 19, 1987 · Apt 4E

    Closed — Violation closed
  • B

    D26-10.01 adm code & 309 m/d law abate the nuisance consisting of key operated double cylinder lock 4 sty apt 4e. , section '' ''

    Jun 9, 1986 · Apt 4E

    Closed — Violation closed

DOB building violations · 13

  • Low pressure boiler boiler required

    Violation issued-failure to file 2018 external low pressure inspection

    Jun 20, 2023

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Sep 2, 2020

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jan 22, 2020

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jan 22, 2020

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jan 22, 2020

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Jan 22, 2020

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Nov 13, 2019

    Dob violation - dismissed
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2016 inspection report

    Apr 6, 2018

    Dob violation - dismissed
  • Construction other optional

    .due to truck impacting sidewalk shed

    Nov 12, 2017

    Dob violation - dismissed
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2015 inspection report

    Feb 24, 2017

    Dob violation - dismissed
Show 3 more ↓
  • Low pressure boiler boiler required

    Violation issued for failure to file annual boiler 2014 inspection report

    Oct 1, 2015

    Dob violation - dismissed
  • Immediate emergency anythingoptional

    Imegncy-immediate emergency anythingoptional

    Feb 25, 2014

    Dob violation - dismissed
  • Plumbing none

    P-plumbing none

    Jan 25, 1989

    Dob violation - dismissed

ECB violations · 72

  • Class - 1

    Failure to notify dept of incident that resulted in fatality or injurynote:worker moving barrier cut finger by chain taken to offsite medical facility:per dob (dept) records 35stynb permit holder failed to noti

    Jul 21, 2022 · Penalty $2,500

    Resolve
  • Class - 1

    Failure to institute safety measure, one of the workers get injured on job site when he was removing barrier with chain link fence, it was no pre shift safety meeting to make the worker be aware of danger, crea

    Jun 15, 2022 · Penalty $10,000

    Resolve
  • Class - 1

    The storage area at the street level was not in accordance to the site safety plan as the barriers and chain link fence was not used for the entire area also construction fence was removed and placed with barri

    Jun 15, 2022 · Penalty $2,500

    Resolve
  • Class - 1

    Observed debris container at exposure 1 storage area was filled over the rim without any protection or cover creating an immediate hazardous to pedestrians passing by the area. also in contrary with code for co

    Jun 15, 2022 · Penalty $2,500

    Resolve
  • Class - 1

    Failure to institute/maintain safety equipment measures or temporary construction-no handrails.at the time of my inspection of a proposed 35story new building.i observed an active construction site with review

    May 18, 2022 · Penalty $2,500

    Resolve
  • Class - 1

    Bc 3301.2 failure to institute/maintain safety measures.lack of egress/ingress.at the time of my inspection of a proposed 35 story new building i observed a lack of egress/ingress throughout jobsite on floors 3

    May 18, 2022 · Penalty $2,500

    Resolve
  • Class - 2

    3303.7.2 fire extinguishers shall be provided in accordance with the nyc fire code.at the time of my inspection of a proposed 35 story new building i observed fire extinguishers on the floor throughout jobsite.

    May 18, 2022

    Resolve
  • Class - 2

    Failure to maintain adequate housekeeping per section requirements at the time of my inspection of a proposed 35 story new building i observed a lack of housekeeping throughout jobsite,i observed furniture boxe

    May 18, 2022

    Resolve
  • Class - 1

    Failure to maintain safety measures/no handrails.at time of inspection of new construction building 35 floors observed staircase 1 & 2 no handrails from 33 down to 2nd fl makes dangerous conditions for workers

    Mar 2, 2022 · Penalty $2,500

    Resolve
  • Class - 1

    Failure to institute/maintain safety equipment measures or temporary construction-guardrails.at time of inspection of a 35 story new building under construction,i observed an area at the bulkhead roof level at

    Jun 2, 2021 · Penalty $2,500

    Resolve
Show 40 more ↓
  • Class - 1

    Work does not conform to approved construction documents and/or approved amendments.at time of inspection of a 35 story new building under construction,i observed suspended scaffolds at exp2,3,and 4 and a suppo

    Jun 2, 2021 · Penalty $2,500

    Resolve
  • Class - 1

    Work does not conform to approved construction documents and/or approved amendments.at time of inspection of a 35 story new building under construction,i observed suspended scaffolds set-up at the roof and bulk

    Jun 2, 2021 · Penalty $625

    Resolve
  • Class - 2

    3316.9.1 competent person not designated by contractor using the equipment-no designation letter provided.noted:at time of inspection of a 32 story new building active jobsite i observed multipoint suspended sc

    Mar 12, 2021

    Resolve
  • Class - 1

    Reasonable (prudence) @the time of inspection of 35 sty new bldg with essential authorization to secure flooding area & electrical wiring incellar only. i observed multiple trades working throughout the bldg

    May 29, 2020 · Penalty $2,500

    Resolve
  • Class - 1

    Failure to comply with governor's executive order #202.6, 202.8, 202.11, 202.13 & guidance published by the empire state devlopment corporation pursuant to same. @the time of inspection observed ongoing const

    May 29, 2020 · Penalty $2,500

    Resolve
  • Class - 1

    Site safety manager/coordinator failed to immediately notify the dept of conditions as required. note:at the time of my inspection of a 35 story building w/ active work. i observed at exposure 3 there is a skyl

    Feb 5, 2020

    Resolve
  • Class - 1

    Failure to promptly notify the dept of an accident or damage to adjoining property at construction site. note:at the time of my inspection of a 35 story building w/ work in progress. i observed at exposure 3 a

    Feb 5, 2020 · Penalty $5,000

    Resolve
  • Class - 1

    Failure to institute and maintain safety equipment measure and temporary construction. note:at the time of my inspection of a 35 story building responding to a complaint where the adjacent bldg skylight was bro

    Feb 5, 2020 · Penalty $10,000

    Resolve
  • Class - 1

    Failure to perform successful hydrostatic pressure test of standpipe system. note:at the time of my inspection of 33 story building at level32 approx 298',construction work in progress. upon review of dept reco

    Feb 5, 2020 · Penalty $5,000

    Resolve
  • Class - 1

    Overhead protection for adjoining property is not provided.at time of inspection in response to complaint#1532415 observed at exposure#3 thefire escape passage way for the adjoining building was left unprotecte

    Jan 2, 2020 · Penalty $2,530

    Resolve
  • Class - 1

    Work does not conform to approved construction documents and/or approved amendments~at time of inspectoin at 32 story building under construction i observed boom lift at expo1(street level)spider crane at exp1(

    Oct 28, 2019 · Penalty $2,500

    Resolve
  • Class - 1

    Work does not confrom to approved construction documents and/or approved documents~at time of inspection of a 32 story building under construction i observed that spider crane on the 30th floor at expo1 was not

    Oct 28, 2019

    Resolve
  • Class - 1

    Bc33014-inspections for embedded safety straps.at time of inspection oa new 32 story under construction,i observed safety straps embedded inconcrete in use at several locations.upon request for the inspection l

    Oct 28, 2019

    Resolve
  • Class - 1

    Work does not conform to approved construction documents and/or approved amendments.at time of inspectoin a 32 story building under construction,i observed that the standpipe compressor was located at the 1st f

    Oct 28, 2019 · Penalty $2,500

    Resolve
  • Class - 1

    Unlawfully work while on notice of a stop work order.~at time of inspection a 32 story building under construction,i observed an active stopwork order all work 10ft from leading edge at expo.3.i observed active

    Oct 28, 2019 · Penalty $5,000

    Resolve
  • Class - 1

    Failure to institute-maintain safety measures~at time of inpsection ofa 32 story building under construction i observed there was no overhead protection for the adj.property aleyway expo as required.*stop all w

    Oct 28, 2019 · Penalty $10,000

    Resolve
  • Class - 1

    Bc33012-failure to institute-maintain satefy measures.~at time of inspection of a 32 story building under construction i observed the following unsafe conditions,loose material such as pipes left untide and uns

    Oct 28, 2019 · Penalty $2,500

    Resolve
  • Class - 1

    Failure to maintain/display on site documents required by chapter 33.at time of inspection of a 32 story building under construction,i observed a jekwo crane at the 30th fl-working deck.upon request for drawing

    Oct 28, 2019

    Resolve
  • Class - 1

    Work does not conform to approved construction documents and/or approved amendments.at time of inspectiong of a 32 story building under construction,i observed that the temporary platforms in the elevator shift

    Oct 28, 2019 · Penalty $2,500

    Resolve
  • Class - 1

    Bc 3301.2 failure to maintain safety measures.@time of inspection of inspection of a 32 sty building under const i observed active work on a suspended scaffold. @the adjoining property building @exp3, in close

    Oct 28, 2019 · Penalty $2,500

    Resolve
  • Class - 1

    3310.3.site safety plan.note:at time of my inspection on a 32story nb i observed no overhead protection for the adjacent property walkway at exp#3 after reviewing site dafety plan it did not indicate adjacents

    Oct 24, 2019

    Resolve
  • Class - 1

    Failure to protect-electrical cords note: @the time of my inspection of a 32 sty bldg under const, i observed @exp4 @the basement lvl electrical extension cords(multiple) with live elctrical current laying on

    Sep 5, 2019 · Penalty $2,500

    Resolve
  • Class - 2

    3303.14 water accumulation @the time of my inspection of a 32 sty building under construction, @the basement lvl @exp 4 i observed standing water approxiametly 1' inch depth.rem: pump water.

    Sep 5, 2019 · Penalty $625

    Resolve
  • Class - 1

    Bc3301.1.2/failure to comply w/nyc fire code-fire watch 32 story new building at 17 story level at the time of my inspection i observed a worker cutting rebar via a power operating too which caused sparks.upon

    Aug 1, 2019 · Penalty $2,500

    Resolve
  • Class - 1

    Failure to perform hydrostatic pressure test for tempo standpipe as required.proposed 32 story new building 217th story level.at the time ofmy inspection i observed in the dob systems,bis and dob now there was

    Aug 1, 2019 · Penalty $5,000

    Resolve
  • Class - 1

    Bc3301.4/failure to maintain/display on site documents required by chapt 33,proposed 32 story building @ 17 story level.at the time of inspection i observed a spider crane and x climber stored on the 14th story

    Aug 1, 2019

    Resolve
  • Class - 1

    Superivision or use of power operated hoisting machine w/o a machine operators license.32 story new building @ 17 story level.at the time ofmy inspection i observed a 2800 capacity sprider crane stored on 14 st

    Aug 1, 2019

    Resolve
  • Class - 1

    Bc3301.1/failure to comply with osha standards-ppe fall protection.at the time of my inspection i observed workers working with out or inadequate fall protection during a concrete operation.workers was seen in

    Aug 1, 2019

    Resolve
  • Class - 1

    Failure to safeguard all person and property by construction.operations 32 story building @ 17th story level a the time of my inspection i observed holes that varied from +2inches to approx +10inches x +6ft,tha

    Aug 1, 2019 · Penalty $10,000

    Resolve
  • Class - 2

    Failure to maintain adequate housekeeping per section requirments 32 story new building @ 17 story level at the time of my inspection i observed piles of garbage being stored on the jobsite not in compliance wi

    Aug 1, 2019

    Resolve
  • Class - 1

    Bc3303.2.3.1/failure to provide temporary lighting to jobsite at the time of my inspection i observed the temporary ligting int he elevator shaft area was not provided and the natural daylight did not provide a

    Aug 1, 2019 · Penalty $2,500

    Resolve
  • Class - 1

    Ssm failed to notify of conditions to dob-use of crane. at the time ofmy inspection i observed a 5800 lb capacity crane in use at the 17th story level hoisting materials from the 8th story level. the ssm marco

    Aug 1, 2019

    Resolve
  • Class - 1

    Bc3319.10.1/failure to provide license for duties being performed signal operator propose 32 story new building at 17 story level at the time of inspection i observed materials being hoisted from the 8th story

    Aug 1, 2019

    Resolve
  • Class - 1

    Unsafe storage of materials during construction operation proposed 32 story new building @ 17 story level at the time of my inspection i observed materials being stored at the perimeters,some on wheels,below th

    Aug 1, 2019 · Penalty $2,500

    Resolve
  • Class - 1

    Bc3303.16/failure to construct shanty according for section required.at the time of my inspection i observed a shanty constructed at the 4thstory level within +-20ft of another shanty,made only of fire retarden

    Aug 1, 2019 · Penalty $2,500

    Resolve
  • Class - 2

    No signs. at time of inspection i observed an active construction sitewith rebar and form work on progress, during inspection noted on the 7floor and up no signs of any exposure as required by code. rmdy: compl

    Jul 3, 2019

    Resolve
  • Class - 1

    Bc3303.7.2 failure to provided fire extinguisher in accordance with the new york city fire code. at time of inspection i observed an active construciton site with rebar and form work in progress, during inspe

    Jul 3, 2019 · Penalty $2,500

    Resolve
  • Class - 1

    Bc3310.4 failure to provide 2 means of egress (site safety program) at time of inspection on an active excavation it was observed that there was no 2 means of egress which should be maintained at all times

    Feb 5, 2019 · Penalty $2,500

    Resolve
  • Class - 1

    Failure to communicate required information to workers during pre-shift safety meeting. in response to an incident (#1500472) that took plc on 1/30/10 in which a worker sustained an injury to his left knee by

    Feb 4, 2019 · Penalty $5,000

    Resolve
  • Class - 1

    Failure to comply with manufacturer's specifications in response to anincident (#1500472) that took place on 1/30/190 in which a worker sus tained an injury to his left knee by usinga stihlts420 to cut timber.

    Feb 4, 2019 · Penalty $2,500

    Resolve

Complaints

  • Heating

    Heat related

    Oct 29, 2011 · Apt 3K

    Close
  • Heating

    Heat related

    Dec 14, 2009 · Apt 2R

    Close
  • Heating

    Heat related

    Dec 5, 2009 · Apt 2R

    Close
  • Heating

    Heat related

    Nov 12, 2009 · Apt 3R

    Close
  • Nonconst

    Vermin

    Jun 15, 2009 · Apt 2R

    Close
  • Nonconst

    Rubbish

    Jun 15, 2009 · Apt 2R

    Close
  • Nonconst

    Rubbish

    Jun 15, 2009 · Apt 2R

    Close
  • Nonconst

    Janitor/super

    Jun 15, 2009 · Apt 2R

    Close
  • Heating

    Heat related

    Mar 26, 2009 · Apt 4R

    Close
  • Heating

    Heat related

    Mar 25, 2009 · Apt 3R

    Close
Show 40 more ↓
  • Heating

    Heat related

    Mar 25, 2009 · Apt 4R

    Close
  • Heating

    Heat related

    Mar 24, 2009 · Apt 3R

    Close
  • Heating

    Heat related

    Mar 23, 2009 · Apt 3K

    Close
  • Heating

    Heat related

    Mar 23, 2009 · Apt 4R

    Close
  • Heating

    Heat related

    Mar 22, 2009 · Apt 3R

    Close
  • Heating

    Heat related

    Mar 21, 2009 · Apt 3R

    Close
  • Heating

    Heat related

    Mar 20, 2009 · Apt 4R

    Close
  • Nonconst

    Rubbish

    Mar 19, 2009 · Apt 2R

    Close
  • Heating

    Heat related

    Mar 19, 2009 · Apt 2R

    Close
  • Heating

    Heat related

    Mar 17, 2009 · Apt 2R

    Close
  • Heating

    Heat related

    Mar 13, 2009 · Apt 3R

    Close
  • Heating

    Heat related

    Mar 13, 2009 · Apt 3R

    Close
  • Heating

    Heat related

    Mar 5, 2009 · Apt 4R

    Close
  • Heating

    Heat related

    Mar 3, 2009 · Apt 3R

    Close
  • Heating

    Heat related

    Feb 11, 2009 · Apt 3R

    Close
  • Heating

    Heat related

    Feb 9, 2009 · Apt 2R

    Close
  • Heating

    Heat related

    Feb 7, 2009 · Apt 3W

    Close
  • Heating

    Heat related

    Feb 7, 2009 · Apt 5W

    Close
  • Heating

    Heat related

    Feb 7, 2009 · Apt 3R

    Close
  • Heating

    Heat related

    Feb 6, 2009 · Apt 3R

    Close
  • Heating

    Heat related

    Feb 5, 2009 · Apt 4R

    Close
  • Heating

    Heat related

    Feb 5, 2009 · Apt 3R

    Close
  • Heating

    Heat related

    Feb 4, 2009 · Apt BLDG

    Close
  • Heating

    Heat related

    Oct 31, 2008 · Apt 4R

    Close
  • Heating

    Heat related

    Oct 30, 2008 · Apt 2R

    Close
  • Heating

    Heat related

    Oct 30, 2008 · Apt 3W

    Close
  • Heating

    Heat related

    Oct 29, 2008 · Apt 3R

    Close
  • Heating

    Heat related

    Oct 29, 2008 · Apt 2R

    Close
  • Heating

    Heat related

    Oct 28, 2008 · Apt 2R

    Close
  • Heating

    Heat related

    Oct 28, 2008 · Apt 5W

    Close
  • Heating

    Heat related

    Oct 27, 2008 · Apt 3W

    Close
  • Heating

    Heat related

    Oct 27, 2008 · Apt 2R

    Close
  • Heating

    Heat related

    Oct 26, 2008 · Apt 4R

    Close
  • Heating

    Heat related

    Oct 22, 2008 · Apt 2R

    Close
  • Heating

    Heat related

    Oct 22, 2008 · Apt 3W

    Close
  • Heating

    Heat related

    Oct 21, 2008 · Apt 5W

    Close
  • Heating

    Heat related

    Oct 21, 2008 · Apt 3R

    Close
  • Heating

    Heat related

    Oct 8, 2008 · Apt 5W

    Close
  • Heating

    Heat related

    Oct 7, 2008 · Apt 3W

    Close
  • Heating

    Heat related

    Oct 6, 2008 · Apt 2R

    Close

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Hotel (H2)
Year built
2019
Floors
35
Residential units
—
Building area
105,328 ft²
Lot area
4,938 ft²
Zoning
M1-8A/R11
Community board
105
Council district
3
Block / lot
803 / 58
Assessed value
$24,885,450
Landmark / historic district
No

HPD registration #132934, last renewed Aug 15, 2018.

Questions about 132 West 28 Street

Who owns 132 West 28 Street?

The owner of record in NYC Department of City Planning PLUTO data is 28th Steet Properties LLC.

Does 132 West 28 Street have violations?

Yes. NYC HPD has recorded 39 housing violations at this property.

Is 132 West 28 Street rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was 132 West 28 Street built?

City records list 2019 as the year it was built.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.