roofy

242 West 22 Street

Manhattan, NY 10011BBL 1-00771-0061Map

Owner of record: Roystar Investment Corp

242 West 22 Street is a walk-up apartment building built in 2016 in Manhattan, 10011. It has 3 residential units across 5 floors. The owner of record is Roystar Investment Corp. HPD has recorded 1 housing violation here, most recently on October 2, 2015.

HPD violations
1
DOB violations
2
ECB violations
20
HPD complaints
1

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
Last violation Oct 2, 2015

Date of the most recent HPD inspection that found a problem.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 1

  • I

    And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.

    Oct 2, 2015

    Closed — Violation dismissed

DOB building violations · 2

  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Aug 10, 2016

    Dob violation - dismissed
  • Fail to certify class 1 none

    Failure to certify correction on immediately hazardous (class 1) ecb violation

    Aug 10, 2016

    Dob violation - dismissed

ECB violations · 20

  • Class - 2

    Occupancy contrary to that allowed by the certificate of occupancy or buildings department records. tco#121193528t003 issued 10/07/19-expires 01/05/20 indicates building as a 5 story structure with cellar.occup

    Nov 21, 2019 · Penalty $625

    Resolve
  • Class - 2

    Built contrary to plan, equipment on site is contrary to approved plannote: at time of inspection i observed supported scaffold in place on exp1 and #3 is contrary to design. 1-missing complete guardrail system

    Sep 20, 2018

    Resolve
  • Class - 2

    Plans. work does not conform to approved construction documents.note: at time of inspection i observed shed in place that is contrary to design. a-missing cross brces in pedestrian passageway for shed, 12 and

    Sep 20, 2018 · Penalty $620

    Resolve
  • Class - 1

    Sec: bc3304.7. failure to provide @ least 1 safe means of egress from bldg. a 5 story new bldg under construction @ 1st flr level, active job site w/ 6 workers engaged in block laying to external walls. observe

    May 15, 2017 · Penalty $1,600

    Resolve
  • Class - 2

    Failure to maintain adequate housekeeping per section requirements. a 5 story new bldg under construction @ 1st flr level, construction work in progress in masonry block installation to external walls. observed

    May 15, 2017 · Penalty $400

    Resolve
  • Class - 2

    Failure to post non-smoking signs @ construction demolition site as per code. @ time of insp of a 5 story new bldg under construction @ 1st flr level, work in progress, recieving deliveries, block work installa

    May 15, 2017

    Resolve
  • Class - 1

    Failure to provide adequate pedestrian for sidewalk & walkways. @ time of insp of a 5 story new bldg under construction @ 1st flr level, work in progress in recieving deliveries from boom truck @ street level i

    May 15, 2017 · Penalty $4,800

    Resolve
  • Class - 1

    Failure to institute/maintain safety equipment measures or temporary construction. no hand rails. a 5 story new bldg under construction @ 1st flr level, active job site w/ 6 workers engaged in block work instal

    May 15, 2017 · Penalty $1,000

    Resolve
  • Class - 2

    Failure to institute/maintain safety equipment measures or temporary construction. no rebar caps. a 5 story bldg under construction @ 1st flr level, work in progress in different trades, masonry block work inst

    May 15, 2017 · Penalty $800

    Resolve
  • Class - 2

    No approved plans on site at time of inspection. at the time of inspection no dob approved soe or foundation plan were provided at the time of inspection. remedy: provide plan.

    Oct 12, 2016 · Penalty $250

    Resolve
Show 10 more ↓
  • Class - 2

    Bc3309.6,bc1814.3.failure to monitor adjoining structures for movementin all direction during excavation related activity that may adverselyaffect adjoining structures.at the time of inspection it was observed

    Aug 9, 2016

    Resolve
  • Class - 2

    Failure to provide approved/accepted plans atjobsite at time of inspection.at the time of inspection the plans for the foundation was inadequate.there was no indication on the plan where the bottom of the adjoi

    Aug 9, 2016

    Resolve
  • Class - 1

    Failure to safeguard all persons and property affected by constructionoperations.at the time of inspection there was no rebar caps on the rebar.in addition,there was no guard rail at exposure 1 at the gate to

    Aug 9, 2016 · Penalty $5,000

    Resolve
  • Class - 1

    Sec. 3309.9 weatherproof intergrity of adjoining property. note: at time of inspection demolition jobsite bldg to grade. exp32 adjacent property not completly weather proofed,front corner exposed(bach)not seale

    May 19, 2016 · Penalty $1,600

    Resolve
  • Class - 1

    Sec. 3307.7 fences. not maintained. at time of inspection observed demolition site. exp#4 (1) 22nd st the const fence is not of solid construction,not solid throughout spliced splitered wood openings,loose pane

    May 19, 2016 · Penalty $1,600

    Resolve
  • Class - 2

    Sec. 3303.3 obstruction of sidewalk w/o dot permit. note: observed active demolition iste. there is a porter john on sidewalk w/no dot permit on site to place on sidewalk. remedy: remove porter john or obtain

    Jan 6, 2016

    Resolve
  • Class - 1

    Sec. 3301.2 safety & standards: no overhead protection. note: observed active demolition jobsite. at exp#3 toward rear at site the adjacent yard at exp#2 needs to be protected. this is a hazard to persons/prope

    Jan 6, 2016 · Penalty $1,600

    Resolve
  • Class - 2

    Failure to maintain adequate illumination beneath sidewalk shed as required by code.noted:sidewalk shed erected under job#140429169,along exposure 1 has inoperable & shadowy;creating a potential risk to public

    Jan 5, 2016

    Resolve
  • Class - 2

    Permit posting. at time of inspeciton i noticed a construction fence erected & sidewalk shed. no permits posted for demolition as per bldg code. remedy: provode & post permit on const fence as per bldg code.

    Dec 22, 2015 · Penalty $400

    Resolve
  • Class - 1

    Failure to safeguard all persons & property affected by construction operations. note: observed active demolition jobsite 3-4 workers on site cleaning debris. there were no temporary lights set up & minimal

    Nov 10, 2015 · Penalty $2,400

    Resolve

Complaints

  • Appliance

    Sprinker cert

    Jul 26, 2004

    Close

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Walk-up apartment building (C0)
Year built
2016
Floors
5
Residential units
3
Building area
7,583 ft²
Lot area
2,469 ft²
Zoning
R8B
Community board
104
Council district
3
Block / lot
771 / 61
Assessed value
$643,260
Landmark / historic district
No

HPD registration #137317, last renewed Oct 22, 2015.

Questions about 242 West 22 Street

Who owns 242 West 22 Street?

The owner of record in NYC Department of City Planning PLUTO data is Roystar Investment Corp.

Does 242 West 22 Street have violations?

Yes. NYC HPD has recorded 1 housing violations at this property.

Is 242 West 22 Street rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was 242 West 22 Street built?

City records list 2016 as the year it was built.

How many apartments are in 242 West 22 Street?

It has 3 residential units.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.