310 West 39 Street
Manhattan, NY 10018BBL 1-00762-0046Map
Owner of record: Libshap Realty Corp
310 West 39 Street is a garage / gas station built in 1940 in Manhattan, 10018. The owner of record is Libshap Realty Corp. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 56
- ECB violations
- 32
- HPD complaints
- 0
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 56
- Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Oct 4, 2023
Dob violation - dismissed - Construction other optional
Reinforcmnt of conc slab=corrodd&exposed w spalled conc cvr=structrly compromised@undrside of roof fl & 2fl slabs,conc encasmnt of lvl 1 fl beams removed,brick cracks@elevatr machine rm. remedy:retain nys rdp 2 evaluate whole bldg. file job appl 4 permanent repairs by 7/28/23 repair bldg under permit to begin by 8/25/23
May 24, 2023
Dob violation - dismissed - Construction other optional
Emergency work-as noted:observed reinforcement of the concrete slabs are corroded & exposed with spalled concrete cover & are in a structurally compromised condition at numerous locations at underside of roof floor & the 2nd floor slabs
May 9, 2023
Dob violation - dismissed - Construction other optional
The occupied parking structure with conc framing observed to be in the state of disrepair. cracks, conc spalling & exposed steel reinf. observed on columns/beams/slabs/girders @ various lvls/locations. an area of slab ceiling missing observed at several locations in cellar lvl. also, rusted/deteriorated steel and shoring noted at front of
May 1, 2023
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Feb 2, 2023
Dob violation - dismissed - Failure to post energy grade/score none
Failure to display energy efficiency score and energy efficiency grade as per adcode sec. 28-309.12.3
Dec 1, 2022
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Nov 2, 2022
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Aug 2, 2022
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Jun 1, 2022
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 24, 2021
Dob violation - resolved
Show 40 more ↓
- Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tst
Sep 6, 2019
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tst
Sep 6, 2019
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Aug 2, 2019
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
May 2, 2019
Dob violation - dismissed - Elevator annual inspection / test elevatorrequired
Violation issued to elevator - failure to file category 1 2017 inspection/test
Apr 5, 2019
Dob violation - dismissed - Elevator annual inspection / test elevatorrequired
Violation issued to elevator - failure to file category 1 2017 inspection/test
Apr 5, 2019
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst
Jan 26, 2018
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2016 cat 1 insp/tst
Jan 26, 2018
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Jan 24, 2018
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jan 24, 2018
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 1, 2017
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 1, 2017
Dob violation - resolved - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2015 cat 1 insp/tst
Jan 3, 2017
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2015 cat 1 insp/tst
Jan 3, 2017
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2014 cat 1 insp/tst
Nov 14, 2016
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2014 cat 1 insp/tst
Nov 14, 2016
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Jan 20, 2016
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jan 20, 2016
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
May 22, 2014
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
May 22, 2014
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Sep 6, 2013
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Sep 6, 2013
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 5, 2012
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 5, 2012
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 15, 2011
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 15, 2011
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Apr 22, 2010
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Apr 22, 2010
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 16, 2009
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 16, 2009
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 26, 2007
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 26, 2007
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Sep 18, 2006
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Sep 18, 2006
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Mar 8, 2005
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Mar 8, 2005
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Sep 5, 2003
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Sep 5, 2003
Dob violation - resolved - Elevator elevatorrequired
1f2825
Jun 21, 2001
Dob violation - resolved - Elevator elevatorrequired
1f2826
Jun 21, 2001
Dob violation - resolved
ECB violations · 32
- Class - 1
Failure to comply with the commissioner's order in dob violation vio23-01260,dated 5/1/2023.respondent was required to submit an engineer's report concerning structurally deficient conditions.as of 10/11/2023,a
Oct 11, 2023
Resolve - Class - 1
Lithium battery storage room is not located in a separately built room or lined with substantial noncombustible material and it is not constructed to prevent the entrance of ignitable amounts of flying or lint
May 2, 2023 · Penalty $1,600
Resolve - Class - 1
Bldgs. or portions thereof that contain, lithium-ion battery devices shall be designed and constructed in accordance with section 309.3 of the nyc fdny code; bc 406.11 2022, comply with code
May 2, 2023 · Penalty $2,500
Resolve - Class - 2
Occupancy contrary to that allowed by the certificate of occupancy or buildings department records : at time of inspection of a 6 story bldg. observed at cellar level ebike electric charging station is active.
May 2, 2023 · Penalty $1,250
Resolve - Class - 2
Noted: at time of inspection, observed that the emergency lights on all levels throughout the building are inoperative. creating a hazardous condition in the event of an emergency., repair/replace lighting
May 1, 2023 · Penalty $312
Resolve - Class - 1
Noted: all levels/locations of the building have severe running cracks, missing and excessive spalling masonry with exposed steel, q-decking that is rusted and flaking. cellar level has an area at the front wit
May 1, 2023 · Penalty $1,250
Resolve - Class - 2
Noted: at time of inspection, observed that unapproved shoring has been installed at the front of the building at cellar level to support a failing steel beam. no permits on file for this work., obtain all perm
May 1, 2023 · Penalty $1,250
Resolve - Class - 1
Failure to maintain building wall(s) or appurtenances : at time of inspection, observed building wall in a hazardous state of disrepair, with multiple glass windows broken and pieces of broken glass remain in w
Jun 8, 2022 · Penalty $6,250
Resolve - Class - 2
34r07 40i10 40x10 100m07 68m07 68b07 01b10 32j01 42g11. 34r07-windows need vertical bars in hoistway as per code 2.1.2 windows in hoistway. 40i10-skylight cracked over controller. 40x10-lights inoperative in ma
May 5, 2014 · Penalty $2,500
Active - Class - 2
Exit passageway partially obstructed. noted: @ garage cellar to 1st fl(ground fl) 2"x4" & sheetrock installed restricts exit passage,at front. parked cars reduce exit passageway at rear. remedy: remove all item
Nov 7, 2013 · Penalty $530
Resolve
Show 22 more ↓
- Class - 2
Exit doors not self closing. noted: at garage,the fire proof doors at stairwells are not self closing at cellar rear,& floors marked 1 & 2 &roof bulkhead. remedy: repair &/or replace/maintain fire doors self
Nov 7, 2013 · Penalty $530
Resolve - Class - 2
Failure to maintain bldg in code compliant manner. noted: at garage cellar,cracked & broken cast iron storm leader riser on left & right w/rain water cascading into cellar. remedy: repair or replace storm leade
Nov 7, 2013 · Penalty $500
Resolve - Class - 2
Failure to maintain building in code compliant manner. note:at cellar level concrete spalling from ceiling beams at various locations. also note steel q-decizing at ceiling is rusting. rem:repair all defects ma
Jan 4, 2012
Resolve - Class - 1
Failure to provide unobstructed exit passageway. note:exit stairways from 6th fl to 1st fl are blocked by cars. rem:remove obstructions forthwith.
Jan 4, 2012 · Penalty $6,000
Active - Class - 1
Failure to maintain building in code-complaint manner. noted: rear brick wall at the back staircase on the 1st flr level is budging. remedy:repair and/or replace brick wall.
Sep 24, 2009 · Penalty $1,000
Active - Class - 2
Failure to maintain building in code-complaint manner. noted: concrete slate steps at the rear staircase is broken/cracked located between 1st & cellar level. remedy: repair/replace stairs.
Sep 24, 2009
Resolve - Hazardous
Failure to maintain exterior bldg! defects noted: 5 courses of brick by 7'-0" approx broken, defective, loose w/ dislodgement at parapet wall south elevation in danger of collapsing southeast section. northeast
Dec 15, 2006 · Penalty $800
Resolve - Non-hazardous
Failure to post cert. of occupancy. remedy : post cert. of occupancy
Oct 21, 2005
Resolve - Non-hazardous
Failure to maintain exterior in that at the front of the bldg windows are cracked and missing glass at various locations at each floor of this six story garage. remedy : maintain bldg / repair or replace all wi
Oct 21, 2005 · Penalty $800
Resolve - Hazardous
Failure to maintain: note (1)spalling concete & cracked with exposed & hanging rebar & exposed i beams. at ceilings slabs at various areas throughout of loose concrete (2)defective metal fire stairs with missin
Jul 29, 2004 · Penalty $2,000
Resolve - Hazardous
Exit door total obstruction: note (1)front fire stairs at basement exit door obstructed with large wood shoe shine stand (2)at street termiation, wood panels/door at office (w airconditioner) & closed roll down
Jul 29, 2004 · Penalty $1,200
Resolve - Hazardous
Failure to maintian: note: (1)spalling, cracked loose concrete with exposed & hanging rebar at concrete ceiling slabs, various locations throughout (2)defective metal fire stairs (front) with a missing step (3-
Jul 29, 2004
Resolve - Hazardous
Exit door total obstruction. note (1)front fire stairs at basement, exit door obstructed with large wood shoe shine stand & motor scoters. (2)at street level termination wood panels/door (with air conditioner i
Jul 29, 2004 · Penalty $480
Resolve - Hazardous
16d06/21n10/39d06 21-cease use of device car runs with doors open 16-doors do ot lock mechanicaly on floors 2,3 & 4 39 secure handrail to motor rooms stairway call 212 566 5539 when ready for service 39-provid
Mar 17, 2004 · Penalty $500
Resolve - Hazardous
21n10/16d06/40d06 21-cease use of device car repairs with doors open 16-repair all doors to lock mechanically 40-secure motor room
Mar 17, 2004 · Penalty $500
Resolve - Hazardous
Exit door total obstruction note:exit doors at front stairway are obstructed throughout bldg with parked cars obstructing egress to firestairs at all floors and at basement exit stairs obstructed with debris.
Mar 16, 2004 · Penalty $480
Resolve - Non-hazardous
Failure to maintain:note (1)spalling cracked concrete loose with exposed rebar and exposed i beams below slabs throughout. (2)defective elevator doors allow operation of elevator with shaft doors open-condition
Mar 16, 2004 · Penalty $800
Resolve - Non-hazardous
Exit sign defective/fails to meet bldg code standards note:there is anabsence of illuminated exit signs at fire doors and fireescape exits throughout at all floors.remedy:provide replace exits signs as per cod
Mar 16, 2004 · Penalty $250
Resolve - Non-hazardous
18n11,73##. 73-cease use of elevator until necessary repairs are madeto hoistway interlocks. car running w/ shaft doors open. 18-repair interlock. call 212-312-8738 when car is ready for service.
Apr 21, 1999 · Penalty $1,250
Resolve - Non-hazardous
73##,18n11,15j1,18d6. 73-cease use until necessary repairs are made tohoistway interlocks. 18-repair interlocks. call 212-312-8738 when car is ready for service. cease using elevator w/ shaft doors open.
Apr 21, 1999 · Penalty $1,250
Resolve - Non-hazardous
73#,18i, 73-cease use until items. 18i-are remied and call 212-312-8738 when workin completed and car is to be put in service.
Aug 4, 1998 · Penalty $500
Resolve - Non-hazardous
15j,18d, 15-adjust all hoistway doors and install locking devices. 18-replace lock covers and adjust locks.
Aug 4, 1998 · Penalty $2,500
Resolve
Complaints
No HPD complaints in our records
Sales history
No recorded sales in our data
Building details
- Building type
- Garage / gas station (G1)
- Year built
- 1940
- Floors
- 6
- Residential units
- —
- Building area
- 27,473 ft²
- Lot area
- 4,937 ft²
- Zoning
- C6-4M
- Community board
- 104
- Council district
- 3
- Block / lot
- 762 / 46
- Assessed value
- $2,628,450
- Landmark / historic district
- No
Questions about 310 West 39 Street
Who owns 310 West 39 Street?
The owner of record in NYC Department of City Planning PLUTO data is Libshap Realty Corp.
Does 310 West 39 Street have violations?
NYC HPD has no housing violations on record for this property.
Is 310 West 39 Street rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 310 West 39 Street built?
City records list 1940 as the year it was built.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.