500 West 33 Street
Manhattan, NY 10001BBL 1-00702-7501Map
Owner of record: Unavailable Owner
500 West 33 Street is a condominium built in 2015 in Manhattan, 10001. The owner of record is Unavailable Owner. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 32
- ECB violations
- 58
- HPD complaints
- 7
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 32
- Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Aug 2, 2023
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Aug 2, 2023
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued-failure to file 2018 external low pressure inspection
Jun 20, 2023
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued-failure to file 2018 external low pressure inspection
Jun 20, 2023
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued-failure to file 2018 external low pressure inspection
Jun 20, 2023
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued-failure to file 2018 external low pressure inspection
Jun 20, 2023
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued-failure to file 2018 external low pressure inspection
Jun 20, 2023
Dob violation - dismissed - Low pressure boiler boiler required
Violation issued-failure to file 2018 external low pressure inspection
Jun 20, 2023
Dob violation - dismissed - Construction other optional
Observed ice accumulated on glass panels above the edge balcony at 100 floor level. glass panels are slope and ice layer accumulated on top of glass panel at expo # 01 along 10th ave. accumulated ice started melting, flying with wind and falling around as small pieces.
Feb 25, 2022
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Sep 1, 2021
Dob violation - dismissed
Show 22 more ↓
- Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Aug 3, 2021
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Jun 3, 2021
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jan 6, 2021
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Aug 2, 2020
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
May 2, 2020
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Jan 22, 2020
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jan 22, 2020
Dob violation - resolved - Retaining wall none
Failed to file cycle 1 technical report by 12/31/2018 per rcny 103-09
Oct 1, 2019
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jun 26, 2019
Dob violation - dismissed - Construction other optional
C-construction other optional
Apr 10, 2019
Dob violation - active - Construction other optional
C-construction other optional
Apr 10, 2019
Dob violation - active - Construction other optional
C-construction other optional
May 15, 2018
Vp*-violation unserved ecb- dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Dec 13, 2017
Dob violation - dismissed - Construction other optional
C-construction other optional
Sep 20, 2017
Vp*-violation unserved ecb- dismissed - Construction other optional
C-construction other optional
Aug 31, 2017
Vp*-violation unserved ecb- dismissed - Construction other optional
C-construction other optional
Aug 31, 2017
Vp*-violation unserved ecb- dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jun 28, 2017
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jun 28, 2017
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jun 28, 2017
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
May 31, 2017
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
May 3, 2017
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
May 2, 2017
Dob violation - dismissed
ECB violations · 58
- Class - 1
Cease use item: device will not run and has a overspeed fault that may have caused the device to cease operation. the accident inspection cannot be performed at this time. . remedy: restore to service immediate
Mar 20, 2025 · Penalty $1,250
Resolve - Class - 1
C/u;95m07,05m05:95-m-07 provide safety switches on escalators to prevent operation when security gates is lowering or lowered. maintain elevator conveying system to lift email dob at [email protected]. must
Jan 26, 2023
Resolve - Class - 1
C/u;95m07,05m05:95-m-07-provide safety switches on escalators to prevent operation when security gates is lowering or lowered. maintain elevator conveying system 05-m-05 perform file and test must obtain permit
Jan 26, 2023
Resolve - Class - 1
Provide safety switch on escalator to prevent operation when security gate is lowering or lowered
Jun 1, 2022 · Penalty $1,280
Resolve - Class - 1
Provide safety switch on escalater to prevent operation to escalator when security gate is lowering or down
Jun 1, 2022 · Penalty $1,280
Resolve - Class - 1
Observed ice accumulated on glass panels above the edge balcony at 100 floor level. glass panels are slope and ice layer accumulated on top of glass panel at expo # 01 along 10th ave. accumulated ice started me
Feb 25, 2022 · Penalty $12,500
Resolve - Class - 1
100####: 100## - failure to report an escalator accident promptly accident occurred on 2-12-2021 at approx 10:58am personnel injuries requiring medical attention
Feb 20, 2021 · Penalty $2,530
Resolve - Class - 1
Bc3301.8.1 tampering w/evidence note:-at time of my inspection of a 68story new bldg,bldg completed at demobilization level in response to an incident reported where one worker was pushing on a frame cart w/loa
Oct 13, 2020 · Penalty $2,500
Resolve - Class - 2
Restore to service inspection can be made by this dept.
Jan 15, 2020 · Penalty $310
Resolve - Class - 2
68b7/18m7/59u15-(68b7)maintenance log insufficient(18m7)missing hoistway door reinforcement on lobby doors(59u15)missing updated brake maintenance tags.remedy:provide sufficient maintenance log provide door rei
Dec 27, 2019 · Penalty $312
Resolve
Show 40 more ↓
- Class - 2
57m7-fire extinguisher missing.
Dec 26, 2019
Resolve - Class - 2
68b7/59u15-(68b7)maintenance log insufficient(59u15)brake maintenance needs to up to date.remedy:provide sufficient maintenance log,provide up to date brake maintenance tags.
Dec 26, 2019 · Penalty $312
Resolve - Class - 2
80b14/71x10-(80b14)runby less than bin,ropes need to be shortened.(71x10)pit light not working.
Dec 26, 2019 · Penalty $310
Resolve - Class - 2
Failure to institute & maintain all safety measures. at time of inspection of a 68 sty nb currently at roof level in response to incident were it was reported by site safety manager security guard was walking
Aug 19, 2019
Resolve - Class - 1
Failure to immediately notify the department of an accident at construction/demolition site. at time of inspection responding to a incident was happen on 05/22/2019 at 4:25 pm, i was informed by the ssm what ha
May 28, 2019 · Penalty $5,000
Resolve - Class - 2
Failure to institute & maintain safety measures for material handling @job site. @time of inspection observed an active const site with interior work in progress. job site is @finishes stage. during inspection
May 16, 2019 · Penalty $5,000
Resolve - Class - 1
Failure to safeguard all persons and property affected by construction operations at time of inspection observed no overhead protection for public sidewalk workers using 2 boom lifts over sidewalk without prote
Mar 13, 2019
Resolve - Class - 2
Respondent failed to make the proper notification for mobile crane af ter may 1, 2018. mobile crane cn#104/18 cd#4383 arrived and departed from 500 west 33 street but did not notify the dept of its departure.
Feb 26, 2019
Resolve - Class - 2
Failure to maintain adequate housekeeping per section requirements. at time of inspection responding to a incident, i observed debris on the edge of j1, j2 bank elevator area (debris metal and drywall) this cre
Feb 14, 2019 · Penalty $625
Resolve - Class - 1
Bc3301.2. failure to safeguard all public and property affected by construction operations. at time of inspection responding to a incident, i was informed by the site safety manager wasnt happy; around 10:45 i
Feb 14, 2019
Resolve - Class - 1
Failure to maintain safe operations. @ time of insp for an incident where security guard was struck by a block of styrofoam due to high winds was injured & went to hospital condition no severe injury was report
May 15, 2018
Resolve - Class - 1
Site safety plan (no available / site safety program. in response to an incident were a worker got injured while operting/leaving scissor lift, i requested to see ssp for construction operations. site safety
Apr 5, 2018 · Penalty $2,500
Resolve - Class - 1
Bc3301.8 failure to immediately notify dept (incident) in response to an incident were a worker got injured while operating/exiting scissor lift.incident happened on 04/04/18 around 3:30pm. incident reported to
Apr 5, 2018 · Penalty $2,500
Resolve - Class - 1
Failure to maintain safe operations (scissor lift) in response to an incident were a worker got injured while operating/exiting scissor lift.it was reported to me by jennifer mattson/witness tht worker while
Apr 5, 2018 · Penalty $10,000
Resolve - Class - 2
Sec: bc 3303.4.1. maintenance all sites shall be free of all tripping hazards such as ice. noticed @ time of insp nb in progress notified ice patches throughout floors on 52nd through 60th flr. workers working
Dec 26, 2017 · Penalty $400
Resolve - Class - 2
Failure to safeguard note:at time of inspection of a 6 story new building (retail bldg)under construction with ( 0 installing ( )a piece approximately 14"x4" feet and ( )who was inspecting
Nov 9, 2017 · Penalty $5,000
Resolve - Class - 1
Sec. 3301.1.2 failure to comply w/nyc fire code general fire guard. at time of inspection pbserved active job site. torch operations are in progress on floors 56 through 61 an inadequate supply of fire guards
Oct 31, 2017 · Penalty $4,000
Resolve - Class - 1
Failure to safeguard all persons & property affected by construction operations.tower crane(cd #4189 cn #29715)located on top of building being constructed @ 500 west 33rd st.crane lifting ball was lowered to a
Oct 31, 2017 · Penalty $1,600
Resolve - Class - 1
Sec. 3308.5 vertical safety netting-not maintained. at time of inspection observed,active job site. the vertical safety netting has not been maintained on floors 44,45,46,48,& 52 along the perimeter edge of the
Oct 31, 2017 · Penalty $4,000
Resolve - Class - 1
Sec. 3313.1 combustible liquid not stored properly. at time of inspection observed,active job site. a gas can is observed on the 55th fl notstored properly as required & is putting persons on site at risk of a
Oct 31, 2017 · Penalty $1,600
Resolve - Class - 1
3301.2.safety measures:note at time of an incident of worker falling from from 57st to 56st while doing street operations.(upon mixing)at site active site with steel operations from 52 to 57 st-no witness to in
Sep 20, 2017 · Penalty $1,600
Resolve - Class - 2
Failure to safeguard all persons,public and property.at time of inspection observed,active jobsite.the bldg/steel structure is approx 54 stories at this time,responding to complaint#1459260.the site safety mana
Aug 31, 2017 · Penalty $5,000
Resolve - Class - 1
Bc3301.1.12:failure to comply w/nyc fire code-general no fire guard.at time of inspection observed,active jobsite.workers are found on the 26th fl and in staircase a perfoming torch operations w/o a fire guard
Aug 31, 2017 · Penalty $1,600
Resolve - Class - 1
No guard rail.at time of inspection i observed active jobsite.no gurard rail in place for an open shaft on the 35 fl,putting persons on siteat risk of fall hazard.the drop from the 35 fl down the shaft is appro
Aug 31, 2017 · Penalty $1,200
Resolve - Class - 1
Bc3308.5.vertical safety netting is not maintained.at time of inspection observed active job site the vertical safety netting has not been maintained in some locations on floors 39,42,43,45 and 46.the netting i
Aug 31, 2017 · Penalty $400
Resolve - Class - 1
Cease use 3318.5.1 1009 68m07 100m07(100n9)photo safety edge tampered/altered/bypassed with duck tape allowieng a bigger hist (fothose)on the hoist (pling)the capacity more than allowed (onc more) then what
Apr 7, 2017
Resolve - Class - 1
3318.5.1 cease use (110-n-9)safety not bypassed with jumper on the controller allowing a bigger square further on the hoist making the capacity more than what is allowed (onc)contact dob to lift cease use.
Apr 7, 2017 · Penalty $1,600
Resolve - Class - 1
97b07. unsafe use of hoisting equipment failure to adhere to materialhandling plan. as per rs18-7 26.7 rmdy:safeguard public and property by expoloring material ho() la.
Apr 7, 2017
Resolve - Class - 1
100n9 safety not bypassed with jumper on the controller allowing a bigger square footage on the hoist makin the capacit more than what was allowed and more than what the hoist safety can handle.remove jumper
Apr 7, 2017 · Penalty $1,600
Resolve - Class - 1
3318.5.1 cease use 100n9 68m07 100m07 (100n9)photo safety (edpe)tempered/altered/bypassed with duck tape allowing a bigger square footageof the hoist making the capacity more than allowed once more then what
Apr 7, 2017
Resolve - Class - 1
Bc3301.1.1/responsibilty or safety:obstructed egress.note:at the time of inspection dob incident worker hit his head while accessing perman ent staircase @ the 10th flr.worker struck his head on temporary door
Mar 15, 2017 · Penalty $1,600
Resolve - Class - 1
Failure to safeguard-responding to an incident of a time in a container on the 34 story.site safety manager and five safety manager states that a five started in a debris container on the 34 story.fire was exti
Mar 9, 2017
Resolve - Class - 1
Failure to safeguard.noted:at time of inspection of an incident a worker walking below was hit by a plywood that fell from the 10th flr.during stripping operating around detention tank.no control access zone to
Feb 13, 2017 · Penalty $5,000
Resolve - Class - 1
Use of power operated hoisting machine w/o a hoisting machine operator's license. see stop work order(swo#020617-rh-01) at time of inspection,above respondent was using valla electric operated could not provide
Feb 6, 2017 · Penalty $1,600
Resolve - Class - 1
Sec. 3319-01(l)3(iv)failure to notify before making repairs to hoisting equipment(structural). at time of inspection,respondent above made structural repairs to crane w/o prior approval from the dept. responden
Jan 4, 2017
Resolve - Class - 2
Temporary construction equipment on site- expired permit. noted: @ time of insp permit for sidewalk shed that installed on 10 ave expired on 11/16/16. rem: renew shed permit.
Dec 13, 2016
Resolve - Class - 2
Work does not conform to approved plans. noted: @ time of insp sidewalk shed does not extend 5ft past the bldg on the right handside, does not cover the entire width of the sidewalk & installed on 10 ave side o
Dec 13, 2016
Resolve - Class - 1
3318.3 97r#-manlift been loaded in hoist w/o been powered down as per anssi 10.4 see 28.1
Oct 19, 2016 · Penalty $1,600
Resolve - Class - 1
2318.5 97r# powered jack been loaded onto hoist w/o been powered down as per ansi a10.4 section 28.1.
Oct 19, 2016 · Penalty $1,600
Resolve - Class - 1
97r#. manlift been loaded in hoist without being powered down 25 per as per a psi a10.4 sec28.1.
Oct 19, 2016
Resolve
Complaints
- Unsanitary condition
Pests
Jul 3, 2023 · Apt 3B
Close - Door/window
Door
Nov 12, 2019 · Apt BLDG
Close - Elevator
Maintenance
Nov 12, 2019 · Apt BLDG
Close - Unsanitary condition
Garbage/recycling storage
Nov 12, 2019 · Apt BLDG
Close - General
Signage missing
Nov 12, 2019 · Apt BLDG
Close - Electric
No lighting
Nov 12, 2019 · Apt BLDG
Close - Elevator
Maintenance
Nov 12, 2019 · Apt BLDG
Close
Sales history
No recorded sales in our data
Building details
- Building type
- Condominium (RC)
- Year built
- 2015
- Floors
- 68
- Residential units
- —
- Building area
- 3,224,812 ft²
- Lot area
- 198,898 ft²
- Zoning
- C6-4
- Community board
- 104
- Council district
- 3
- Block / lot
- 702 / 7501
- Assessed value
- $764,317,801
- Landmark / historic district
- No
Questions about 500 West 33 Street
Who owns 500 West 33 Street?
The owner of record in NYC Department of City Planning PLUTO data is Unavailable Owner.
Does 500 West 33 Street have violations?
NYC HPD has no housing violations on record for this property.
Is 500 West 33 Street rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 500 West 33 Street built?
City records list 2015 as the year it was built.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.