161 Bowery
Manhattan, NY 10002BBL 1-00424-0006Map
Owner of record: Nm Bowery LLC
161 Bowery is an office building built in 1920 in Manhattan, 10002. The owner of record is Nm Bowery LLC. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 29
- ECB violations
- 23
- HPD complaints
- 0
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 29
- Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Nov 26, 2024
Dob violation - dismissed - Construction other optional
Emergency work order:due to unsafe conditons observed@ west elevation exposure #1:cracked concrete at 7th floor remedy:immeidately provide safety measures/sidewalk shed @ west elevation and repair the defected facade
Sep 9, 2023
Dob violation - active - Hazardous condition (facade) facade required
Cycle 9a unsafe report filed
Aug 30, 2023
Dob violation - active - Failure to correct swarmp conditions (facade) facade required
Cycle 9a failure to correct swarmp conditions
Aug 30, 2023
Dob violation - active - No report and / or late filing (facade) facade required
Failed to file fisp cycle 9a technical report by 02/21/2022
Feb 22, 2022
Dob violation - active - Elevator elevatorrequired
E-elevator elevatorrequired
May 20, 2020
Dob violation - resolved - No report and / or late filing (facade) facade required
Failed to file fisp cycle 8a technical report by 02/21/2017
May 31, 2018
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 2, 2017
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
May 6, 2016
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
May 11, 2015
Dob violation - resolved
Show 19 more ↓
- Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2012 cat 1 insp/tst
May 30, 2014
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
May 1, 2014
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jul 24, 2012
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Mar 16, 2010
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Apr 8, 2009
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jul 10, 2008
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Jul 10, 2008
Dob violation - resolved - Elevator elevatoroptional
Ll1081-local law 10/81 - elevator elevatoroptional
Mar 21, 2008
Dob violation - dismissed - Facade facade optional
Ll1198-local law 11/98 - facade facade optional
Nov 30, 2007
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Sep 5, 2006
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Dec 1, 2005
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 17, 2005
Dob violation - resolved - Facade facade required
L1198-local law 11/98 - facade facade required
Aug 8, 2002
Dob violation - dismissed - Elevator elevatorrequired
1p2544
Jun 4, 2002
Dob violation - resolved - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Mar 26, 2002
Dob violation - dismissed - Elevator elevatorrequired
1p2544
Jun 22, 2000
Dob violation - resolved - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
Feb 7, 2000
Dob violation - dismissed - Elevator elevatorrequired
1p2544
Feb 8, 1999
Dob violation - resolved - Elevator elevatorrequired
51-repair mtrm walls
Jan 17, 1989
Dob violation - resolved
ECB violations · 23
- Class - 1
Occupancy contrary to that allowed by the certificate of occupancy or building department records. as noted: time of inspection observed at cellar a club/event space with d.j./speakers makeshift bar and seating
Aug 22, 2026 · Penalty $2,500
Active - Class - 1
Failure to maintain exterior building facade and appurtenances. note:-on exp #2(north elevation) which includes cracked decorative stine/terra cotta at nw corner(6th flr); and spalled/spalling cementatious coat
Sep 3, 2024 · Penalty $6,250
Resolve - Class - 2
Failure to maintain exterior building facade and appurtenances. note:-observed deteriorating masonry on exp #2(north elevation) which includes spalled/spalling cementious coating/paint and cracked decorative st
Mar 9, 2024 · Penalty $3,125
Resolve - Class - 2
Failure to file acceptable amended cycle 9a report indicating correction of unsafe conditions described in initial facades report required by 28-302.5 for control#900775.rem:file acceptable report.
Jan 16, 2024 · Penalty $1,250
Resolve - Class - 2
At time of inspection observed 3 story mixed use building with sidewalk shed in place with lighting not in operating condition.provide lighting dusk till dawn
Nov 9, 2023 · Penalty $5,000
Resolve - Class - 2
Failure to maintain building exteriors and appurtenances. at time of inspection defective facade observed at various locations and exposures. ýrepairs not done. as per dob vol #090923fa0301mh¨. (a)-exposure #1
Oct 27, 2023 · Penalty $1,250
Resolve - Class - 1
Failure to take/provide required measures to secure public safety at adesinated unsafe building facade. unsafe notification "fisp3"#unsafe-900775-9a-001 was filed on 08-22-2023. at time of inspection i observed
Sep 9, 2023 · Penalty $12,500
Resolve - Class - 2
Failure to submit an acceptable required cycle 9a report of critical examination documenting condition of exterior wall and appurtenances required by 28-302.4 for control#900775.remedy:submit acceptable require
Dec 9, 2022 · Penalty $1,250
Resolve - Class - 2
Failure to submit an acceptable 6th round technical report in compliance w/ code provisions periodic insp of exterior walls and appurtenances as required by article 28.302 and the dob rules & regulations rem: f
Nov 21, 2008
Resolve - Non-hazardous
Work without a permit sidewalk sed at time of inspection sidewalk shed was erected and dob record shows no permit was issued for sidewalk shed remedy obtain permit as per code
Aug 14, 2002 · Penalty $800
Resolve
Show 13 more ↓
- Non-hazardous
49-install and pipe down discharge piping one safety value.
May 31, 2002
Resolve - Non-hazardous
49 install and pope down discharge piping on safety value.
May 31, 2002 · Penalty $180
Resolve - Non-hazardous
Occupancy contrary to that allowed by the building dept.records.noted:1)records 7fl show occupancy of factory now occupied as a martial artsd.j.and office 2)5fl records shows factory use now occupied as a 5 bdr
Mar 24, 2000 · Penalty $800
Resolve - Non-hazardous
Work without a permit -all work complete noted: floor joist cut and opening created at south/side rear of 1 fl leading to cellar .wood step installed and temporary 4"x4" wood supports installed supporting remai
Mar 22, 2000
Resolve - Hazardous
Failure to maintain building exterior. noted: at front facade 1) se- paration of ornamental stone work atop columns at 2/3rd floor level. 2) vertical crakcs at stone above 2nd floor windows. remedy: provide
Apr 22, 1999 · Penalty $800
Resolve - Non-hazardous
Failure to submit a fourth round techical report inspection of exterior walls and appurtenances as required by local law 10 of 1980 and the department of bldg rules and rewgulations remedy file the required rep
Feb 9, 1999 · Penalty $400
Resolve - Hazardous
Failure to submit a 4th round technical report: periodic inspection ofexterior walls & appurtenances as required by ll 10 of 1980 & the deptof bdlgs rules & regulations. remedy: file the required report.
Nov 24, 1998 · Penalty $10,000
Resolve - Hazardous
Failure to submit a fourth round technical report: periodic inspection of exteoir wall and appurtenances as required by local law 10 of 1980 and the department of buildings rules and regulations
Jul 21, 1998 · Penalty $10,000
Resolve - Hazardous
Failure to maintain exterior building wall. in that ornamental concrete units situated a top cast iron columns are in danger of dislocating due to cracks (1/2" air gaps) at the corners. remedy: obtain permits
Jun 16, 1998 · Penalty $2,500
Resolve - Hazardous
Failure to submit a forth round technical report: periodic inspection of exterior walls and appurtenances as required by local law 10 of 1980 and the department of buildings rules and regulation. remedy: file t
Apr 16, 1998 · Penalty $2,500
Resolve - Non-hazardous
17a. top hand hole cover corroded weld replace gasket.
Mar 17, 1993 · Penalty $250
Resolve - Non-hazardous
46a,46b,6a. safety valve leaking. sight glass dirty also leaking at steam end.
Mar 16, 1993
Resolve - Non-hazardous
Failure to file a report of compliance with local law 16/84 certifyingto the installation of required fire protection systems. remedy-file report
Feb 26, 1991 · Penalty $500
Resolve
Complaints
No HPD complaints in our records
Sales history
No recorded sales in our data
Building details
- Building type
- Office building (O6)
- Year built
- 1920
- Floors
- 7
- Residential units
- —
- Building area
- 18,994 ft²
- Lot area
- 2,664 ft²
- Zoning
- C6-1G
- Community board
- 103
- Council district
- 1
- Block / lot
- 424 / 6
- Assessed value
- $2,767,050
- Landmark / historic district
- No
Questions about 161 Bowery
Who owns 161 Bowery?
The owner of record in NYC Department of City Planning PLUTO data is Nm Bowery LLC.
Does 161 Bowery have violations?
NYC HPD has no housing violations on record for this property.
Is 161 Bowery rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 161 Bowery built?
City records list 1920 as the year it was built.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.