163 Orchard Street
Manhattan, NY 10002BBL 1-00416-0058Map
Owner of record: Nadico Hospitality, LLC
163 Orchard Street is a hotel built in 2009 in Manhattan, 10002. The owner of record is Nadico Hospitality, LLC. HPD has recorded 9 housing violations here, most recently on November 17, 2025.
- HPD violations
- 9
- DOB violations
- 16
- ECB violations
- 63
- HPD complaints
- 3
What to know
No open immediately-hazardous violations among recent records.
Date of the most recent HPD inspection that found a problem.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 9
- IInformation / order
And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.
Nov 17, 2025
Closed — Violation dismissed - ANon-hazardous
File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.
Apr 17, 2024
Closed — Violation dismissed - ANon-hazardous
File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.
Mar 31, 2023
Closed — Violation dismissed - IInformation / order
And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.
Nov 2, 2022
Closed — Violation dismissed - IInformation / order
And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.
Mar 10, 2022
Closed — Violation dismissed - ANon-hazardous
File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.
Mar 10, 2022
Closed — Violation dismissed - IInformation / order
And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.
Apr 20, 2021
Closed — Violation dismissed - ANon-hazardous
File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.
Apr 20, 2021
Closed — Violation dismissed - IInformation / order
And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.
Nov 6, 2019
Closed — Violation dismissed
DOB building violations · 16
- Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Oct 4, 2023
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 12, 2017
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
May 2, 2016
Dob violation - resolved - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2014 inspection/test
Jun 10, 2015
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jan 14, 2015
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jan 14, 2015
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jul 2, 2014
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jul 2, 2014
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Mar 26, 2014
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Mar 12, 2014
Dob violation - dismissed
Show 6 more ↓
- Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Mar 12, 2014
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jan 15, 2014
Dob violation - dismissed - Construction other optional
C-construction other optional
Sep 8, 2009
Vw*-violation - work w/o permit dismissed - Zoning none
Z-zoning none
Nov 24, 2008
Dob violation - dismissed - Construction other optional
Misc violation, failure to adequately support adjoining ground & structures affected by excavation, @ time of inspection # 104762570, underpinning @ exp 2 (partial) & 4, sheeting & shoring @ exp due to soldier piles driven nexxt to bldg, structure being undermined exp 4 remedy: swo-comply with nov, provide protection, call for appt
Sep 10, 2008
Dob violation - dismissed - Construction other optional
C-construction other optional
Mar 21, 2008
Dob violation - dismissed
ECB violations · 63
- Class - 1
2/x/10 out side comm inoperative repair,6/x/10 class 1 car door restrictor not working tampered with disabled,99/bb/7 one year tag expired provide.
May 5, 2023 · Penalty $3,125
Resolve - Class - 1
Work after hours w/o variance permit contrary to 28-105.12.5 observed12 story in progress.workers are working inside no variance permit presented or obtained as required. "stop all after hours & construction
Oct 25, 2014 · Penalty $1,600
Resolve - Class - 1
Failure to have site safety manager or coordinator present as requiredobserved active job site.workers working inside/work in progress no site safety manager present as required."stop all construction activit
Oct 25, 2014 · Penalty $2,400
Resolve - Class - 2
Permit holder failed to provide access and/or expose work on active site. at time of my inspection observed-active jobsite.workers workinginside fence doors are padlocked waited apprx 25minutes made some reas
Oct 25, 2014 · Penalty $2,000
Resolve - Class - 2
Project information panel not provided or not in compliance w/section.observed 12story nb in place missing required project information panel on the fence as required. rmdy: comply with code.
Oct 25, 2014
Resolve - Class - 1
Work w/o a permit. at time of inspection observed active job site. bldg currently topped out at 12 stories. pipe scaffold is erected at rooflevel around bulkhead. scaffold is approx. 40 ft in height. no permit
May 9, 2014 · Penalty $1,600
Resolve - Class - 1
3318.5.1 *cease use* 05l10,08b07,16b07,68m07,09i07.cu05l:cease use service 1v22710 car door/gate tomahawk defective ,must repair,loading back door/gate was opened while hoist was the six floor.08b:car floor to
Apr 9, 2014
Resolve - Class - 1
Failure to institute/maintain safety equipment measures or temp const no guard rails.at the time of inps observed active job site.12 story bldg.no guard rails have been provided on top of the bulk head-where wo
Apr 7, 2014 · Penalty $2,400
Resolve - Class - 1
Failure to institute safety equipment on supported scaffold noted:no toeboards & guardrails installed on supp scaffolds.stop all work on supp scaffolds @ exp1.contact ssu for re-insp.rem:comply w/ dob code req.
Apr 7, 2014 · Penalty $1,000
Resolve - Class - 1
3309.1 provide protection for roof,sky light,chimney etc.@ the time of insp observed active job site.work need to be done @ exp 2 on top of the parapet.bulkhead of 12 story new bldg.no roof protection has pr
Apr 7, 2014 · Penalty $1,600
Resolve
Show 40 more ↓
- Class - 2
Elect work w/o permit.upon search of dob record on 04.07.14 @ 8:30a.m.no temp const elect permit provided for temp elect work on 12 story new bldg.rem:obtain temporary construction electrical permit.
Apr 7, 2014 · Penalty $400
Resolve - Class - 2
Work does not conform to approved const docs.noted:sws @ exp1 does notconform to plans on site & scanned plans in bis.pictures & pdf plans filed.rem:conform to approved plans.
Apr 7, 2014
Resolve - Class - 1
Failure to provide evidence or workers attending const & safety code. at the time of insp observed active job site.upon insp approx 5 workers dont have required 10 hours osha certification.rem:provide evidence
Apr 7, 2014 · Penalty $1,200
Resolve - Class - 2
3310.6 failure to have designated ssm as indicated on pw2 present on site.upon insp of site safety log book.no record found for designated site safety manager elmer r dawson(#0198)from february 2014.rem:provid
Apr 7, 2014 · Penalty $800
Resolve - Class - 2
Failed to notify dept prior to use/inst off c-hooks in connection w/suspended scaffold. noted: at time of inspection c-hook notification expired on 2-9-14. active rigging work men working on suspended scaffold
Mar 6, 2014 · Penalty $400
Resolve - Class - 2
Failed to notify dept prior to use/inst off outrigger beams in connection w/suspended scaffold. noted: at time of inspection outrigger beamsnotification is expired. outrigger beams in connection w/suspended
Mar 6, 2014 · Penalty $4,000
Resolve - Class - 1
Unlawfully continued work while on notice of a swo. noted: at time of inspection men working on suspended scaffolds while being on notice ofa swo issued 12.18.13. remedy: comply w/swo.
Dec 24, 2013 · Penalty $4,800
Resolve - Class - 1
Sec. 3314.1 all scaffolds shall be erected so that the safety of public will not be endangered by falling material, tools or debris or by collapse of the scaffold. noted: at time of inspection c-hook at exp #2
Dec 18, 2013 · Penalty $1,600
Resolve - Class - 1
Licensed rigger failed to ensure scaffold worker met minimum requirements. noted: at time of inspection following workers: 1. manuel garcia,2.miguel juarez, 3.angel cardenas, 4.raul miguel working on suspended
Dec 18, 2013 · Penalty $8,000
Resolve - Class - 1
3303.11 required means of egress shall be maintained at all times during construction noted: stirs are blocked and have no handrails from the 9th flr then to the 12th flr. rmdy: stop work form the 9th-12th flrs
May 29, 2013 · Penalty $300
Resolve - Class - 2
Job site sign not in compliance w/dob code requirements. noted: sidewalk shed at exposure #1 job site sign under permit #120939306 missing expiration date. pictures filed. remedy: comply w/dob code requirements
Nov 26, 2012 · Penalty $830
Resolve - Class - 1
Failure to safeguard all persons & property affected by construction operations. noted:at time of inspection contractor installed wooden stair 1st flr to 5th flr stairs are made of wood not fine rated or firepr
Aug 1, 2012 · Penalty $2,400
Resolve - Class - 1
3301.7:design drawing required. noted:at time of inspection bldg up to9th flr form work at 1st flr level erected work platform creating a mezzanine level being used to work obtain design drawing wood work platf
Aug 1, 2012 · Penalty $1,600
Resolve - Class - 1
3303.12:elevator or hoist in readiness. at time of inspection hoist not working hoist not kept in readiness at all times ofr fire dept use. rem:stop all work above 75ft call best for re inspection.
Aug 1, 2012 · Penalty $1,600
Resolve - Class - 2
Sec. 28-116.2.3 failure to provide an adequate inspection program. re-inspection call 212-626-9971 as noted: at time of inspection at an active construction site reinforced concrete building is up to 8 stories.
Jul 31, 2012
Resolve - Class - 1
Work does not conform to approved construction documents/or approved amendments as noted: at time of inspection at an active construction site reinforced concrete building is upto 8 stories. i observed at site:
Jul 31, 2012 · Penalty $1,000
Resolve - Class - 2
Sec. 28-104.7 submittal of construction document as noted: at time of inspection at an active construction site reinforced concrete buildingis up to 8 stories. i observed: (#1) opening in structural decks for a
Jul 31, 2012
Resolve - Class - 2
Sec. 3301.7 failure to provide p.e. approved design drawings. as noted: at time of inspection at an active construction site,reinforced concrete building is up to 8 stories,i observed light weight residential
Jul 31, 2012
Resolve - Class - 1
3303.8.1:air pressurized alarm system for dry standpipe systems duringconstruction. noted at time of inspection forming 9th flr deck. 7th flr level above 75ft when air pressurized alarm system required. rem:sto
Jul 30, 2012 · Penalty $1,600
Resolve - Class - 1
1906.6:restores in proximity to facade within 10ft not secured noted:at time of inspection reshores on flrs 5,6,7&8 not secured. rem:stop all work within 10ft of facade 5,6,7,8 secure reshores call best for rei
Jul 30, 2012 · Penalty $1,600
Resolve - Class - 1
3301.7:design drawing required:noted at time of inspection work platforms erected cheer walls at exposure 2&4 exterior side of bldg when asked for designs drawing contractor did not have any work platforms on 6
Jul 30, 2012 · Penalty $1,600
Resolve - Class - 1
28-105.12.8:work is not in accordance with site safety plan. noted at time of inspection roof protection missing on adjoining property skylight protection missing set back protection missing on (aneust)& adjoin
Jul 30, 2012 · Penalty $1,600
Resolve - Class - 1
3308.3:vertical netting not as per code. damaged or inadequate noted at time of inspection on flrs 2 thru 6 at exposures 1&3 vertical nets not as per code they are not set at 60 inches high as required. rem:sto
Jul 30, 2012 · Penalty $1,600
Resolve - Class - 2
Sec. 3310.3 failure to comply w/site safety program at time of inspection no safe safety plan. at site upon request site is open approx 6 workers leading cmu blocks at 1st fl level. remedy: provide approved sit
Nov 21, 2011
Resolve - Class - 1
Failure to have sit safety manager/coordinator. present as required. at time of inspection job site open workers approx 6 loading cmu blocks into site building is at 1st fl. no site safety cordinator present at
Nov 21, 2011
Resolve - Class - 2
Permit not posted noted nb permit issued on renewal basis not posted on construction fence job#104762570 also related fence permit not posted site closed rem: comply w/ notice of violation post all permits
Apr 4, 2011
Resolve - Class - 2
Work w/o a permit. expired permit noted at time of inspection fence permit #104762570-01 fn has expired on 12-20-09 & dob record show no new current valid permit has been obtained. remedy: renew permit.
Aug 10, 2010
Resolve - Class - 2
Work w/o a permit. expired permit. noted the following conditions: permit #104762570-01-nb expired 12.20.09 and permit #104762570-01-eq-fn also expired on 12.20.09 remedy: renew permit.
Feb 17, 2010 · Penalty $800
Resolve - Class - 2
Fail to post work permit on construction or demolition site in a conspicuous location.noted:@ time of insp observed jobsite between to public streets (allen st. & orchard st)with no posted permit for fence prov
Jan 14, 2010
Resolve - Class - 2
Bc3301.9.1(misc)fail to provide a sign with working "to anonymously"report unsafe conditions @ this worksite that endangers workers.noted@time of insp observed jobsite with foundation & 1st fl slab installed
Jan 14, 2010
Resolve - Class - 2
Fail to provide & post required signed @ jobsite pursuant to subsection.noted@ time of inspection observed jobsite fronting two public throughfares (allen st & orchard st) with foundation & 1st fl slab in place
Jan 14, 2010
Resolve - Class - 2
Failure to provide & post sign(s) at job site pursuant to subsection. noted: at time of inspection on construction site w/2 separate public thoroughfare (allen st & orchard st) no signage provided stating name
Apr 15, 2009
Resolve - Class - 2
Sec. 28-105.11;27-194. failure to post work permit on construction or demolition site in conspicuous location. noted: at time of inspection observed at construction site w/2 separate public throughfares. no
Apr 15, 2009
Resolve - Class - 2
Failure to provide a sign w/wording "to anonymously report unsafe conditions at this work site that endangers workers, call 311 in both english & spanish on new bldg or demolition site." at time of inspection
Apr 15, 2009
Resolve - Class - 2
Sec. bc3310.3 failure to have site safety plan & site safety program as required. at the time of inspection foundation completed with 1st flr slab. as per department of building record no site safety plan & pro
Mar 16, 2009 · Penalty $400
Resolve - Class - 2
Job site fence not constructed pursuant to subsection. fence gate defective & found on sidewalk at allen street exposing interior of foundation to 20'- 0 foot drop. jobsite unsafe & unguarded. remedy: repair/ &
Jan 1, 2009
Resolve - Class - 1
Sec.bc3310.8 & 27-1009d & rcny."stop all work".misc. violations.failure to adequately carry out duties of site safety manager as outlined indob manual for site safety programs,may 1988 & chapter 33.noted:at tim
Sep 12, 2008
Resolve - Class - 1
Failure to protect adjoining structures during excavation operations: noted: excavation work done at 168 allen st caused damage to adjoining property at 166 allen st wall in lobby has a separation of approx 1"
Sep 3, 2008 · Penalty $2,400
Resolve - Non-hazardous
Sec. 27-147. work w/o a permit. on inspection approx 40' of job site fence has been constructed 8' high made of wood w/o permits. remedy: "stop all work" obtain permit for fence.
Mar 21, 2008 · Penalty $400
Resolve - Non-hazardous
Sec-147 work w/o a permit (exp.permit) note:upon inspection dob records are showing fence permit no # 104668101-01-eq-fn exp. 12.31.07.remedy: renew permit as per bldg code
Jan 3, 2008 · Penalty $2,500
Resolve
Complaints
- Heat/hot water
Entire building
Aug 25, 2026 · Apt 305
Close - Heat/hot water
Entire building
Jan 20, 2024 · Apt BLDG
Close - Heat/hot water
Apartment only
Dec 9, 2021 · Apt ROOM50
Close
Sales history
No recorded sales in our data
Building details
- Building type
- Hotel (H9)
- Year built
- 2009
- Floors
- 11
- Residential units
- —
- Building area
- 19,024 ft²
- Lot area
- 2,319 ft²
- Zoning
- C4-4A
- Community board
- 103
- Council district
- 1
- Block / lot
- 416 / 58
- Assessed value
- $3,038,400
- Landmark / historic district
- No
HPD registration #144574, last renewed Dec 10, 2025.
Questions about 163 Orchard Street
Who owns 163 Orchard Street?
The owner of record in NYC Department of City Planning PLUTO data is Nadico Hospitality, LLC.
Does 163 Orchard Street have violations?
Yes. NYC HPD has recorded 9 housing violations at this property.
Is 163 Orchard Street rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 163 Orchard Street built?
City records list 2009 as the year it was built.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.