223 East 2 Street
Manhattan, NY 10009BBL 1-00384-0016Map
Owner of record: 223 East 2nd St LLC
223 East 2 Street is a walk-up apartment building built in 1900 in Manhattan, 10009. It has 6 residential units across 7 floors. The owner of record is 223 East 2nd St LLC. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 58
- ECB violations
- 43
- HPD complaints
- 0
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 58
- Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jun 12, 2024
Dob violation - dismissed - Hazardous condition (facade) facade required
Cycle 9a unsafe report filed
Feb 2, 2023
Dob violation - active - Construction other optional
Structure rendered non-compliant. at time of inspection damage observed to have been sustained to entire building due to structural stability compromised determined by feu at 223 e 2nd street manhattan. a full vacate order issued on entire building.
Dec 22, 2022
Dob violation - active - Construction other optional
Exp 3 wall severely bulg out, crackd @all floors structrly compromsd& at risk of collpse.exp 2/3 cornr crckd& posbly undrmnd.rear exp 2&4 wall crckd@ up fls.exp2 rear wall bulg@6 fl slop twd 2/3cornr ownr immd retain nyspe &contrctr instl shor@all fls w/latrl brcng.brce@exp3 wls&r exp2&4.pe prvd f/t onste suprvs work
Dec 21, 2022
Dob violation - dismissed - Construction other optional
Failure to maintain bldg facade and appurtenances. observed damaged window frames on exp1 and cracked stucco at exp4 remedy: maintain bldg exterior walls facade and appurtenances repair defects as per 1rcny 103.04
Oct 18, 2022
Dob violation - active - No report and / or late filing (facade) facade required
Failed to file fisp cycle 9a technical report by 02/21/2022
Feb 22, 2022
Dob violation - active - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 29, 2021
Dob violation - active - Construction other optional
Failure to file an acceptable exterior walls and appurtenance critical examination technical report for cycles 6,7, and 8. filed by a reg design professional as req'd by new york city administrative code, title 28.ch.3 article 302 and the rules of the city of new york 1rcny 103-04. remedy:submit accpetable exterior walls appur report
Oct 27, 2020
Dob violation - active - Elevator elevatorrequired
E-elevator elevatorrequired
May 21, 2020
Dob violation - active - Elevator elevatorrequired
E-elevator elevatorrequired
Sep 4, 2019
Dob violation - active
Show 40 more ↓
- Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Apr 17, 2019
Dob violation - active - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Apr 17, 2019
Dob violation - dismissed - Elevator annual inspection / test elevatorrequired
Violation issued to elevator - failure to file category 1 2017 inspection/test
Apr 5, 2019
Dob violation - active - No report and / or late filing (facade) facade required
Failed to file fisp cycle 8a technical report by 02/21/2017
May 31, 2018
Dob violation - active - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2016 inspection/test
Sep 15, 2017
Dob violation - active - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 7, 2017
Dob violation - active - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2015 inspection/test
Dec 1, 2016
Dob violation - active - Emergency none
Ftm/sws
Nov 25, 2016
Dob violation - dismissed - Residential elevator periodic inspection/test elevatorrequired
Failure to perform category 5 inspection
Jun 1, 2016
Dob violation - active - Elevator elevatorrequired
E-elevator elevatorrequired
Apr 27, 2016
Dob violation - active - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2014 inspection/test
Jun 10, 2015
Dob violation - active - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2013 inspection/test
Oct 31, 2014
Dob violation - active - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2012 inspection/test
Mar 31, 2014
Dob violation - active - No report and / or late filing (facade) facade required
Failed to file fisp cycle 7a technical report by 02/21/2012
Jan 31, 2013
Dob violation - active - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2011 inspection/test
Oct 1, 2012
Dob violation - active - Elevator elevatorrequired
E-elevator elevatorrequired
Jan 26, 2012
Dob violation - active - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2010 inspection/test
Dec 13, 2011
Dob violation - active - Elevator elevatorrequired
E-elevator elevatorrequired
Dec 15, 2010
Dob violation - active - Elevator annual inspection / test elevatorrequired
Vcat1-elevator annual inspection / test elevatorrequired
Oct 8, 2010
Dob violation - dismissed - Elevator elevatoroptional
Ll1081-local law 10/81 - elevator elevatoroptional
Feb 27, 2009
Dob violation - dismissed - Facade facade optional
Ll1198-local law 11/98 - facade facade optional
Nov 30, 2007
Dob violation - active - Elevator elevatorrequired
E-elevator elevatorrequired
Nov 7, 2007
Dob violation - active - Elevator elevatorrequired
E-elevator elevatorrequired
Dec 27, 2006
Dob violation - active - Elevator elevatorrequired
E-elevator elevatorrequired
Nov 15, 2005
Dob violation - active - Elevator elevatorrequired
E-elevator elevatorrequired
Nov 5, 2005
Dob violation - active - Elevator elevatorrequired
E-elevator elevatorrequired
Sep 28, 2004
Dob violation - active - Facade facade required
L1198-local law 11/98 - facade facade required
Aug 8, 2002
Dob violation - active - Elevator elevatorrequired
1p2963
Sep 20, 2000
Dob violation - active - Elevator elevatoroptional
Ll1081-local law 10/81 - elevator elevatoroptional
Jan 20, 1999
Dob violation - dismissed - Elevator elevatoroptional
Ll1081-local law 10/81 - elevator elevatoroptional
Jan 6, 1998
Dob violation - dismissed - Elevator elevatoroptional
Ll1081-local law 10/81 - elevator elevatoroptional
Jan 13, 1997
Dob violation - dismissed - Elevator elevatoroptional
Ll1081-local law 10/81 - elevator elevatoroptional
Jan 13, 1997
Dob violation - active - Elevator elevatoroptional
Ll1081-local law 10/81 - elevator elevatoroptional
Mar 8, 1996
Dob violation - dismissed - Elevator elevatoroptional
Ll1081-local law 10/81 - elevator elevatoroptional
Apr 17, 1995
Dob violation - dismissed - Elevator elevatoroptional
Ll1081-local law 10/81 - elevator elevatoroptional
May 31, 1994
Dob violation - dismissed - Elevator elevatoroptional
1
Jun 28, 1993
Dob violation - dismissed - Facade facade optional
Ll1080-local law 10/80 - facade facade optional
Jul 1, 1992
Dob violation - active - Elevator elevatoroptional
1
Apr 7, 1992
Dob violation - dismissed - Elevator elevatoroptional
1
Apr 25, 1991
Dob violation - dismissed - Elevator elevatoroptional
Ll16-local law 16/84 - elevator elevatoroptional
Jan 28, 1991
Dob violation - active
ECB violations · 43
- Class - 2
Failure to file acceptable amended cycle 6, 7a, 8a, and 9a report indicating correction of unsafe conditions described in initial facades report required by 28-302.5 for control #900730. remedy: file acceptable
Apr 20, 2026 · Penalty $1,250
Active - Class - 1
Bc 3308.1 failure to maintain safety netting in a code compliant manner.at the time inspection observed supported scaffold in place with netting attached at the time of inspection observed large section of safe
Apr 9, 2024
Resolve - Class - 2
Failure to submit acceptable required cycle 6,7a,8a,9a,report of critical examination documenting condition of exterior wall & appurtenancesrequired by 28-302.4 for control#900730.agg2:history of noncompliance
Dec 9, 2022 · Penalty $3,125
Resolve - Class - 2
Failure to maintain exterior building facade & appurtenances.note:at time of inspection observed at exp #4(west el) crack coating/missing coping stone.at exp #2(east el)observed hair crack & missing coping ston
Nov 4, 2022 · Penalty $1,250
Active - Class - 2
Failure to submit acceptable required cycle6,7a,8a report of critical exam documenting condition of exterior wall&appurtenances required by 28-302.4 for control800730.agg2 history of noncompliance on37017459p (
Jun 1, 2021 · Penalty $3,125
Resolve - Class - 2
Failure to maintain building exterior walls/facades and appurtenances exposure 1 north elevation at various stories step cracks cracks 3rd story cracked masonry stone by window jamb 7th story missing glass(has
Apr 23, 2020 · Penalty $1,250
Active - Class - 2
Failure to submit an acceptable required cycle 6, 7a and 8a report of critical exmination documenting condition of exterior wall and appurtenances required by 28-302.4 for control #800730.agg1:prior nov 3701443
Jan 22, 2020 · Penalty $3,125
Resolve - Class - 2
Failure to comply w/ the commissioner's order contained in summons/violation#35375132k issued on 1/25/19 and to file a certificate of correction pursuant to 28-201.1 and 1rcny 102-01. no c/of/c on file. remedy:
Nov 23, 2019 · Penalty $3,125
Resolve - Class - 2
Failure to comply w/the comm's order contained in summons/vio#35375132k issued on 01-25-19 & to file a c of c pursuant to 28-201.1 & 1rcny 102-01. failure to maintain bldg in code compliant manner.
Oct 9, 2019 · Penalty $3,125
Resolve - Class - 1
Failure to comply w/the comm's order contained in summons/vio#35375133m issued on 01/25/19 & to file a c of c pursuant to 28-201.1 & 1rcny 102-01. work w/o permit. remedy: comply w/comm's order &/or file a c of
Aug 2, 2019
Resolve
Show 33 more ↓
- Class - 2
Failure to comply w/the comm's order contained in summons/vio#35375132k issued on 01-25-19 & to file a c of c pursuant to 28-201.1 & 1rcny 102-01. no c of c on file. remedy: comply w/comm's order &/or file a c
Aug 2, 2019 · Penalty $1,250
Resolve - Class - 1
Failure to comply with the commissionrs order contained in summons/ violation # 35375133m issued on 1/25/19 and to file a certificate of correction pursuant to 28-201.1 and 1rcny 102-01. work without a perm
May 18, 2019
Resolve - Class - 2
Failure to comply with the commissionrs order contained in summons/ violation # 35375132k issued on 1/25/19 and to file a certificate of correction pursuant to 28-201.1 and 1rcny 102-01. no c of c on file
May 18, 2019 · Penalty $3,125
Resolve - Class - 2
Failure to comply w/the comm's order contained in summons/vio#35375134k issued on 01-25-19 & to file a c of c pursuant to 28-201.1 & 1rcny 102-01. no c of c on file. remedy: comply w/comm's order &/or file a c
Mar 23, 2019 · Penalty $1,250
Active - Class - 2
Failure to maintain bldg in code complaint manner. noted: at the time of inspection in apt#5 oberved the apt ceiling & walls has stains & some areas was damaged due to the water leak from the above floors pipes
Mar 18, 2019
Resolve - Class - 2
Failure to submit a required cycle 8a report of critical examination documenting condition of exterior wall and appurtenances required by 28-302.4 for control# 800730. remedy: submit required technical report
Feb 11, 2019 · Penalty $1,250
Resolve - Class - 1
Work without permit. noted, premises 7-story attached nfp masonary frame dwelling and 2nd to 5th floor occupied with 4 family. at the time of inspection, i observed, sprinkler system wokr has been done in 6th &
Jan 25, 2019
Resolve - Class - 1
Failure to maintain building in code compliant manner. noted: premises 7-story attached nfp masonary frame dwelling and 2nd to 5th floor occupied with 4-family. at the time of inspection i observed, sprinkler s
Jan 25, 2019 · Penalty $2,500
Active - Class - 2
Temporary construction equipment on site expired permit.note:observed sidewalk shed is in place.sidewalk shed permit #140584455 is expired on 12/16/17.rem:renew permit.
Mar 26, 2018
Resolve - Class - 2
Temporary construction equipment sidewak shed 146584455 expired 12-16-17. rmdy: renew permit.
Jan 3, 2018 · Penalty $400
Resolve - Class - 2
Failure to maintain exterior bldg south elevation expo #1 observed flower pots stored on fire escape landing egress on the 5th and 6th flrs.west elev.exp#2 observed spall,cracks and deteriorating in masonyry fa
Jan 30, 2017 · Penalty $500
Active - Class - 2
Failure to maintain exterior bldg front elev exp#1-decorative parapet defective missing masonry-6fk window cladding detached-6fl window frame wood detached wood-6fl above windows stop cracks-6fl brick has open
Oct 19, 2016 · Penalty $500
Active - Class - 2
Failure to file and acceptable technical report in compliance w/code provisions:periodic inspection of exterior walls and appurtenances as required by article 28.302 and the dob rules and regulations.rmdy:file
Mar 7, 2016 · Penalty $800
Resolve - Class - 2
Failure to maintain facades and appurtenances. noted: at east exposurea crack was observed in the stucco material.other cracks were observedin stucco at east,rear and west exposure.bulging masonry was observed
Jun 2, 2015 · Penalty $500
Active - Class - 2
Failure to file an acceptable cycle 7 technical report in compliance wcode provisions:periodic inspection of exterior walls and appurtenances as requried by article 28.302 and the dob rules and regulations.file
Sep 19, 2014 · Penalty $800
Resolve - Class - 2
Failure to file an acceptable sixth round technical report in compliance with article 28-302 of the bldg code & dob rules & regulations.36017725m.respondent has demonstrated a history of non-compliance w/dept r
Aug 12, 2012 · Penalty $4,000
Resolve - Class - 2
Failure to file an acceptable 6th round technical report in compliancew/code provisions: periodic inspection of exterior walls & appurtenances as required by article 28.302 & the dob's rules & regulations.
Dec 15, 2011 · Penalty $2,000
Resolve - Class - 2
Failure to file an acceptable 6th round technical report in compliancewith code provisions: periodic inspection of exterior walls & appurtenances as required by article 28.302 & the dept of buildings rules &
Jan 25, 2011 · Penalty $2,000
Resolve - Class - 2
Failure to file an acceptable 6th round technical report in compliancewith code provisions:periodic inspection of exterior walls & appurtenaces as required by article 28.302 & the dob rules & regulations.rem:fi
Jul 6, 2010 · Penalty $2,000
Resolve - Class - 2
Failure to maintain bldg wall(s)or appurtenances.noted:@ south elevation concrete coating over brick facade cracking,spalling dislodged various locations thruout @ roof parapet ceramic coping stones dislodged
May 14, 2010 · Penalty $2,500
Resolve - Class - 2
Failure to file an acceptable 6th round technical report in compliancewith code provision: periodic inspection of exterior walls & appurtenances as required by article 28.302 & the dept of buildings rules and
Mar 29, 2010 · Penalty $2,000
Resolve - Class - 2
Failure to submit an acceptable sixth round technical report in compliance w/code provision.periodic inspection of exterior walls & appurtenances as required by article 28.302 & the dept of bldg rules & regulat
Nov 21, 2008 · Penalty $800
Resolve - Hazardous
Failure to maintain exterior bldg wall defects noted east wall of rearyard of 225 east 2 st. observed plaster/ parging of east wall is in disrepair & separating from brick wall. also noted approx 8'-0 sections
May 4, 2007 · Penalty $800
Resolve - Hazardous
Plumbing work w/o permit location throughout bldg gas boilers gas lines installed w/o permit remedy: obtain a permit if feasible or restore to prior legal condition
May 14, 2003 · Penalty $1,000
Active - Non-hazardous
Occupancy contrary to that allowed by the cofo. noted; 4th floor of said premises is being used as living quarters consisting of 3 bedrooms, kitchen and diningroom which is contrary to cofo#35767 office,storage
Jan 2, 2002 · Penalty $800
Active - Hazardous
Failure to maintain building.noted:broken,cracked,defective stairs, landings, & handrails in front & rear stairwells creating danger of tripping & falling.danger that separated rusted metal chips will fall.loca
May 25, 2001 · Penalty $2,500
Resolve - Hazardous
Failure to maintain bldg. noted: front stairwell broken, rusted & damaged throughout. door to elevator shaft at 1st fl broken & damaged& not closed. front stairwell treads & landings cracked, broken & dam
Dec 2, 1998 · Penalty $2,500
Resolve - Non-hazardous
74#-failure to file with this dept. for elevator dismantle and or removal.
Jun 25, 1998 · Penalty $3,500
Active - Hazardous
Failure to submit a fourth round technical report: periodic inspectionof exterior walls and appurtenances as required by local law 10 of 1980 and the department of buildings rules and requlations. remedy:
May 12, 1998 · Penalty $2,500
Resolve - Hazardous
Failure to maintain building exterior noted: at front facade of building 1st and 2nd floor level vertical structural cracks at various locations. stonewalk over door way (side) cracked and pulling away from bui
Apr 6, 1998 · Penalty $2,500
Resolve - Hazardous
Failure to submit a third round technical report. periodic inspection of exterior wall and appurtenances as required by local law 10 of 1980 and the department of buildings rules and regulations. remedy: file t
Apr 25, 1994 · Penalty $500
Resolve - Non-hazardous
Failure to maintain exterior bldg. wall defect is: brickwork cracked and loose, mortar joints open throughout various locations of all exterior walls from 1st sty. to roof parapet. bricks loose and missing.
Oct 20, 1988 · Penalty $1,000
Resolve - Non-hazardous
Failure to maintain exterior building wall defect is brickwork cracked and loose mortar joints open throughout variouslocations of all exterior walls from 1 sty to roof parapet bricks loose and missing from rea
Oct 20, 1988 · Penalty $250
Resolve
Complaints
No HPD complaints in our records
Sales history
No recorded sales in our data
Building details
- Building type
- Walk-up apartment building (C4)
- Year built
- 1900
- Floors
- 7
- Residential units
- 6
- Building area
- 15,185 ft²
- Lot area
- 2,165 ft²
- Zoning
- R8A
- Community board
- 103
- Council district
- 2
- Block / lot
- 384 / 16
- Assessed value
- $1,370,700
- Landmark / historic district
- No
Questions about 223 East 2 Street
Who owns 223 East 2 Street?
The owner of record in NYC Department of City Planning PLUTO data is 223 East 2nd St LLC.
Does 223 East 2 Street have violations?
NYC HPD has no housing violations on record for this property.
Is 223 East 2 Street rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 223 East 2 Street built?
City records list 1900 as the year it was built.
How many apartments are in 223 East 2 Street?
It has 6 residential units and 7 units in total.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.