roofy

91 Attorney Street

Manhattan, NY 10002BBL 1-00348-0064Map

Owner of record: 91/93/95 Highgate LLC

91 Attorney Street is an elevator apartment building built in 2018 in Manhattan, 10002. It has 44 residential units across 8 floors. The owner of record is 91/93/95 Highgate LLC. HPD has no housing violations on record for this property.

HPD violations
0
DOB violations
3
ECB violations
41
HPD complaints
0

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
No HPD violations

HPD has not cited this building.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 0

No HPD violations on record

DOB building violations · 3

  • Failure to benchmark none

    Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4

    Jun 2, 2021

    Dob violation - active
  • Construction other optional

    C-construction other optional

    Nov 20, 2018

    Vp*-violation unserved ecb- dismissed
  • Unsafe buildings none

    Ub-unsafe buildings none

    May 19, 1998

    Dob violation - dismissed

ECB violations · 41

  • Class - 1

    Bc 3303.8 failure to provide stand pipe in state of readiness as required by code.at time of inspection stand pipe was not connected and nottested or ready by code,no doc. provided for any test & i observed tha

    Apr 23, 2019 · Penalty $2,500

    Resolve
  • Class - 2

    Pedestrian protection does not meet code specifications. noted: at time of my inspection of an 8 sty new building construction operations in progress, i observed a garbage truck parked outside exp #1 being load

    Jan 15, 2019 · Penalty $2,400

    Resolve
  • Class - 1

    Failure to institute/maintain safety equipment measures or temporary construction-no guardrails. noted: at time of my inspection of an 8 sty building, construction activities in progress. i observed a balcony o

    Jan 15, 2019 · Penalty $2,500

    Resolve
  • Class - 1

    Failure to file evidence of liability & or property damage insurance.as noted at time of inspection active site,8 story building i observed general liability insurance policy#agl00702304 was expired on 12/03/18

    Dec 4, 2018 · Penalty $5,000

    Resolve
  • Class - 2

    Jobsite fence not maintained-viewing panel. 8 sty new building under construction @ roof lvl active job site viewing panels was painted overand/or obstructed.there was no view into jobsite as required ny nyc do

    Nov 20, 2018

    Resolve
  • Class - 1

    Bc 3301.3&1 failure to have construction superintendent or competent person present @ site when required. 8 sty new building under construction @ roof lvl, active job site at the time of my inspection i observe

    Nov 20, 2018 · Penalty $5,000

    Resolve
  • Class - 1

    Failure to safeguard all persons & property affected by construction operations.8 sty new building under construction @ roof lvl,active jobsite @ the time of inspection i observed the job site fence open to the

    Nov 20, 2018 · Penalty $1,250

    Resolve
  • Class - 1

    3307..6.5.7-installation inspection.at time of inspection on an active jobsite,i observed approx 50 ft sidewalk sited @expo 1, upon request for inspection,installation report none was provided,sidewalk sited sh

    Aug 15, 2018 · Penalty $625

    Resolve
  • Class - 2

    Failure to provide accepted construction documents at time of inspection construction superintendent failed to provide a signed and dated site safety plan on an active construction site.fail to provide adeqaute

    Aug 15, 2018

    Resolve
  • Class - 2

    3301.2-failure to insitute maintain safety measures.at time of inspection on actove jobsite i observed no guardrails or inadequate guardrails , no adequate protection provided or control zone to safeguard worke

    Aug 15, 2018

    Resolve
Show 31 more ↓
  • Class - 1

    Sec. 3309.1 protection required for adjacent property at time of inspection on an active jobsite of 8 sty bldg,currently at 6 sty level,observed that neighbors backyard & balconies had concrete splash from conc

    Jul 31, 2018 · Penalty $2,500

    Resolve
  • Class - 1

    Sec. 3309.10 missing roof protection. at time of inspection on an active jobsite of 8 sty bldg,currently at 6 sty level,i observed that no roof protection existed on exp#4 of the adjacenet bldg. failure to prov

    Jul 31, 2018

    Resolve
  • Class - 1

    Provide adequate protection for pedestrian.at time of my inspection of 8 story building at 4th floor,i observed that the walkway(temporary)that was created was not completly closed off to the walkway close off

    Jul 9, 2018 · Penalty $625

    Resolve
  • Class - 1

    Failure to safeguard public. at time of inspection of a new 8 story building under construction, @ 1st sty stage, active jobsite, i observed construction equipment obstructing the sidewalk. pedestrians being pu

    May 29, 2018 · Penalty $2,500

    Resolve
  • Class - 1

    3301.2 failure to maintain (rebar caps). at time of my inspection of a new 8 story building under construction, at 1st floor level i observed several workers on active job site working among several rebars whic

    May 29, 2018

    Resolve
  • Class - 2

    Illegal signs/signage. at the time of inspection of a 8 story nb under construction at 1st floor level active jobsite, i observed advertising signs and graffiti all over job site fence. rem: remove illegal sign

    May 29, 2018

    Resolve
  • Class - 2

    Logs inadequately maintained.at time of my inspection of a 8 story newbuilding under construction a foundation stage i observed thats the superintendents log book was not signed by hcm on friday 04/27/2018.rem:

    Apr 30, 2018 · Penalty $2,500

    Resolve
  • Class - 1

    Uncapped rebar/failure to maintain i observed uncapped rebar at all exposures of the job site,at the time there were all(11)workeron site. this condition create an unpaling hazard for worker on site. stop all

    Mar 20, 2018

    Resolve
  • Class - 1

    No guardrails. i observed no guardrails at exp#2 of the job site,this condition creates unpaling hazard w/exposed rebar in the area. their is a also a 13 feet drop to the floor of the foundation which is a fall

    Mar 20, 2018 · Penalty $2,500

    Resolve
  • Class - 1

    Failure to designate &/or have a construction superintendent present at site as required. i observed that the super has no been on site for 4 working days,the last entry made was on 3-13-18 & my inspection was

    Mar 20, 2018

    Resolve
  • Class - 2

    Failure to maintain adequate housekeeping per section requirements: noted: excessive debris & materials in vacant lot debris piled up as high as construction fence 8' thru-out vacant lot. remedy: maintain adequ

    Feb 23, 2009 · Penalty $4,000

    Resolve
  • Class - 2

    Job site fence not constructed pursuant to subsection,noted: at the south end of property construction fence missing:4 x 5 section creating easy access onto property & vacant bldg.primary school #142 directly

    Feb 9, 2009 · Penalty $4,000

    Resolve
  • Class - 1

    Sec bc3303.13 27-1027a abandoned demolition operations noted at time of insp observed excessive amount in excess of 200 cubic yards of debris and other combustible material a detective jobsite construction fenc

    Dec 18, 2008 · Penalty $8,000

    Resolve
  • Class - 2

    Exp. permit. noted: const. fence at above location in place. in permit has exp. on 12/31/04 remedy:renew permit

    Jul 29, 2008 · Penalty $4,000

    Resolve
  • Class - 2

    Expired permit. noted: bldg at above location demo to 2nd fl. dm permit was expired on 09.15.05 rem: stop all work, renew permit

    Jul 29, 2008 · Penalty $4,000

    Resolve
  • Non-hazardous

    Work w/o a permit expired permit. upon inspection fence permit expiredon 12/31/04 violation was issued on 9/05/06. remedy: renew permit as per code.

    Sep 14, 2007 · Penalty $2,500

    Resolve
  • Non-hazardous

    Work w/o a permit. expired permit. upon inspection demolition permit has expired on 9/15/05. remedy: renew permit as per code.

    Sep 14, 2007 · Penalty $2,500

    Resolve
  • Non-hazardous

    Failure to comply w/ the commissioners order to correct the violating conditions & file a certificate of correction w/ the nyc dob for notice of viol #34527022n, 34512024p & 34512350k. remedy: correct the viol

    Sep 19, 2006 · Penalty $2,500

    Resolve
  • Hazardous

    Failure to obtain a permit fence upon insp fence erected partically front of 91 attorney st 10ft on southside 10ft on northside last permit site approx abandoned on demo since 1994 no current permit exist

    Sep 5, 2006 · Penalty $2,500

    Resolve
  • Hazardous

    Failure to safeguard public & property upon insp bldg @ 2nd story partically collapsed site is open & unguarded no fence front of section open approx 18ft cond is hazardous to public site across from school

    Sep 5, 2006 · Penalty $5,000

    Resolve
  • Hazardous

    Job site fence defective. noted:section of fence approx 20'missing from existing lot where partially prior demo exists. remedy:repair or replace fence.

    Sep 4, 2006 · Penalty $5,000

    Resolve
  • Non-hazardous

    Work w/out a permit/expired fence permit. noted:fence permit #103921197 issued on 09/23/04 expired:12/31/04. remedy:renew permit immediately.

    Jun 29, 2006 · Penalty $2,500

    Resolve
  • Hazardous

    Failure to maintain adequate house keeping in that, debris from demolished portion of building is being maintained at entire lot, at front and rear creating a health and fire hazard to surrounding occupied

    Mar 10, 2006 · Penalty $1,000

    Resolve
  • Non-hazardous

    Work without a permit- expired permit, permit for construction fence under application #103921197 expired 12-31-04 note- section of fence atnorth side of lot does not meet required height of 8 feet high. remedy

    Mar 10, 2006 · Penalty $2,500

    Resolve
  • Non-hazardous

    Dangerous places and things- in that a sheet metal fence is being maintained with sharp edges at front of demolition site creating a nuisance and safety hazard to pedestrians and students at occupied elementary

    Mar 10, 2006 · Penalty $2,500

    Resolve
  • Non-hazardous

    Expired permit.as noted,fence permit expired dated 12-31-04 & dob records shows no permit is being renewed.at the time,building is partially down & front elev & 3 floors still standing @ rear elev.fence is in p

    Jan 21, 2005 · Penalty $2,500

    Resolve
  • Non-hazardous

    D.o.t. permit for sidewalk closing not posted. demolition at roof and at 3rd floor front wall was started and d.o.t. permit for sidewalk closing was not posted on site. remedy: post d.o.t. permit.

    Oct 20, 2004 · Penalty $400

    Resolve
  • Hazardous

    No sidewalk bridge provided. violation noted: contractor failed to provide sidewalk bride for 3 story building under going demolition. note this building is structurally unsafe (with callaping flooring) side

    Oct 5, 2004 · Penalty $5,000

    Resolve
  • Hazardous

    Failure to carry out demolition work in a safe and proper manner, defect noted: this building was declared unsafe, resulted from collapse ofmiddle section flooring to roof. however, contractor commenced

    Oct 5, 2004 · Penalty $5,000

    Resolve
  • Hazardous

    Failure to safeguard public and property affected by demolition operations. the following unsafe hazardous conditions existed at demolition site (1) contractor installed 8'-0" high plywood fence approximately

    Oct 5, 2004 · Penalty $5,000

    Resolve
  • Hazardous

    Failure to carry out demolition operation in a safe and proper manner upon inspection at above property demo in progress at 3rd wall(front)and front roof glass rent is in street and 3 men on lift doing demoliti

    Oct 1, 2004 · Penalty $5,000

    Resolve

Complaints

No HPD complaints in our records

Complaint data is still being backfilled from NYC Open Data.

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Elevator apartment building (D3)
Year built
2018
Floors
8
Residential units
44
Building area
32,998 ft²
Lot area
6,633 ft²
Zoning
R7A
Community board
103
Council district
1
Block / lot
348 / 64
Assessed value
$6,616,800
Landmark / historic district
No

Questions about 91 Attorney Street

Who owns 91 Attorney Street?

The owner of record in NYC Department of City Planning PLUTO data is 91/93/95 Highgate LLC.

Does 91 Attorney Street have violations?

NYC HPD has no housing violations on record for this property.

Is 91 Attorney Street rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was 91 Attorney Street built?

City records list 2018 as the year it was built.

How many apartments are in 91 Attorney Street?

It has 44 residential units.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.