DOB building violations · 5
- Construction other optional
Noted car into sws displacing 3 posts and damaging building front facade/entry door.
Mar 26, 2022
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Dec 13, 2017
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jun 14, 2017
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Nov 2, 2016
Dob violation - dismissed - Boilers boiler required
Ll6291-local law 62/91 - boilers boiler required
May 4, 1998
Dob violation - dismissed
ECB violations · 36
- Class - 2
Temporary equipment onsite expired permit-supported scaffolding.at time of inspection on inactive construction on a 6 story new building i observed at exposures 1 and 2 a supported scaffolding resting on top of
Apr 12, 2022
Resolve - Class - 2
View panels fence atoi observed jobsite fence 8' that had no viewportsinstalled in fence comply w/code
Mar 28, 2022
Resolve - Class - 2
Temp const equipment onsite expire permit atoi on 6sty observe jobsitefence erected w/expire permit renew permit
Mar 28, 2022
Resolve - Class - 2
Failure to permit holder to provide inspection access to &/or expose ongoing construction or work on an active & permitted worksite.as noted:at time of inspection on an active construction,6-story new bldg job
Feb 16, 2022 · Penalty $1,250
Resolve - Class - 1
Bc3301.2 failure to safeguard all persons&property affected by const operations.atoi of proposed 6stynb,currently@6fl superstructure work inprogress jobsite was inactive.i observed@exp2;fire hydrant obstructed
Jun 3, 2021 · Penalty $2,500
Resolve - Class - 2
Jobsite fence not maintained pursuant to subsec-viewing panels (bc3307.7.3) atoi of proposed 6stynb,currently@6fl superstructure level,jobsite was inactive.i observed const fence in place@exp1&2 under permit121
Jun 3, 2021
Resolve - Class - 2
Bc3307.6.4.9 traffic sign visually obstructed/blocked by sws.atoi of proposed 6stynb currently@6fl superstructure work in progress,jobsite was closed.i observed traffic signage unreasonably obstructed both visu
Jun 3, 2021
Resolve - Class - 1
Bc 3303.4.7 storage near sidewalk,walkways and pathways. note:at the time of my inspection of a 7 story building at the sidewalk level at exposure 2,it was observed storage on roadway adjacent to sidewalk there
Dec 3, 2019 · Penalty $2,500
Resolve - Class - 1
Work does not conform to approved construction documents and/or approved amendments. note:at the time of my inspection of a 7 story building,it was observed at the 4th fl level there was needle beam cantilevere
Dec 3, 2019 · Penalty $2,500
Resolve - Class - 1
3301.2:failure to maintain at the time of my inspection panned 6 sty actiev nb site observed approx 3 workers perform my their jobs on roof level deck they were(wearing harness) it was noted they (not anchor)
Jul 17, 2019 · Penalty $2,500
Resolve
Show 26 more ↓
- Class - 1
3303.11:stairs required within 40 ft of working deck at the tiem fo my inspection planed 6 sty nb/apprx 74 ft roof level work in progress observed no (permanent) or temp staircase at sit it was noted provided o
Jul 17, 2019 · Penalty $2,500
Resolve - Class - 1
Failure to maintain adequate housekeeping at the time of my inspection planed 6 sty nb actiev sit eupto roof level observed inadequate housekeeping const materials and debris created tripped hazard and unsafe w
Jul 17, 2019 · Penalty $2,500
Resolve - Class - 1
3303.9:failure to provide means of egress as per code.at the time of my inspection planed 6 sty nb active site observed approx 3 workers on roof level deck but no ladders or stairs or other way observed to entr
Jul 17, 2019 · Penalty $2,500
Resolve - Class - 2
Insulation placement does not meet min. req. on an energy compliance inspection i observed insulation at exposure (2,3) are installed substandard contrary to approved plans. pswo issued, install insulation and/
May 16, 2019 · Penalty $2,000
Resolve - Class - 2
Fialure to maintain job site fence as per code. @the tim eof insp, planed 6 sty bb, 2 sty deck lvl work in progress. observed inadequatevie w panels on job site fence. not enclosed the gap between sws & fence
May 13, 2019
Resolve - Class - 2
3307.6.5.5 cleaning sws. @the time of my inspection 6 sty panel nb, 2sty deck lvl work in progress. observe const materials and debris all over on side walksed.rem:provide up keep sws clean as per code.
May 13, 2019
Resolve - Class - 1
Failure to maintain/institute safety equipment measures - no guard rails. @the time of my inspection, planned 6 sty nb, 2 sty deck lvl work in progress observed inadequate guardrail system @2fl & 3fl deck was
May 13, 2019 · Penalty $2,500
Resolve - Class - 1
3307.6.5.10 inspection log for sws @the time of my inspection, planned6 sty nb, 2 sty deek lvl work in progress. observed sws in place @exp#1&2. upon request for sws inspection logs, non was provided, no insp
May 13, 2019 · Penalty $625
Resolve - Class - 1
3301.2 fialure to maintain safe opreation. @the time of my inspection , planed 6sty nb, 2 sty deck lvl work in progress. observed workers removing temp support fot the concrete slabs all ready poured, no caz
May 13, 2019 · Penalty $2,500
Resolve - Class - 1
3309.14 window protection.at time of inspection of 6 story nb currently @ 2nd story observed no window protection of adjoining bld. @ expo#22 windows of exp#2's building are accessible from sws of exp#1.as well
Apr 6, 2019 · Penalty $2,500
Resolve - Class - 1
Failure to perform duties.at time of inspection of 6 story nb @ 2nd story observed inadequate egress,unsecured & unattended site,no guardrails,no window protection,uncapped rebar,& inadequate housekeeping.no wo
Apr 6, 2019 · Penalty $10,000
Resolve - Class - 1
Guardrails.at time of inspection observed 6 story nb @ 2nd level.no guardrails anywhere on site ,egress leading to basement as well as unenclosed perimeter over basement with an approx.10' drop.2nd fl. has no g
Apr 6, 2019 · Penalty $5,000
Resolve - Class - 1
3303.11 egress.at time of inspection of 6 story nb currently @ 2nd level, observed inadequate egress path leading to & from egress/ingress blocked by shoring,timber,material & misc debris,less than 2' of egress
Apr 6, 2019 · Penalty $2,500
Resolve - Class - 1
Failure to safeguard/unsecured site.at time of inspection double swinging doors unlocked.no worker on site.holes in floor grade level over 10' drop with no guardrails or fall protection in place.site easily acc
Apr 6, 2019 · Penalty $10,000
Resolve - Class - 1
Uncapped rebar.at time of inspection observed 6 story nb @ 2nd story.observed uncpped rebar on 2nd floor all exposures at height which causes a hazard of impalement.rem:cap rebar maintain safety measures.
Apr 6, 2019 · Penalty $5,000
Resolve - Class - 1
Housekeeping.at time of inspection of 6 story nb currently @ 2nd levelobserved piles of timber,shoring & misc debris which made navigating through the site dangerous & uncomfortable.entire site had tripping haz
Apr 6, 2019 · Penalty $2,500
Resolve - Class - 2
Failure to provide approved/accepted construction documents at the jobsite at the time of inspection.at this time of inspection it was observed that no dob approvd soe plans were onsite upon request to verify t
Dec 13, 2018
Resolve - Class - 2
3309.6 failure to monitor adjoining structures for movement in all directions.during excavation related activity that may adversely affect adjoining structures.at time of inspection it was observed that contr
Oct 10, 2018
Resolve - Class - 2
3307.3.2 failure to provide lot line fence. at time of inspection i observed no construction fence in place at exp #4 rear. at occupied adjacent property construction fence was clearly indicated on s.s.p
Oct 10, 2018
Resolve - Class - 2
Construcion superintendent failed to perform duties as per code. at the time of inspection the registered superintendent "jun zhen" was not onsite.the following violating condition took place. 1)logbook
Oct 10, 2018 · Penalty $312
Resolve - Class - 1
3306.5.1deficient drawings.the respondent failued to meet the minimum requirements set forth in bc3306.5.1 mandates demolition documents contain plans,sections & details clearly showing applicaiton #122659024 d
Sep 8, 2017 · Penalty $1,600
Resolve - Class - 2
Ac 28-306.2 the respondent failed to meet the minimum reqs.(jet) forth ac 28-306.2.ac 28-306.2 requires the(maintenance)of a party wall in accordance w/bc 3309.after a fukk demo of 355 grand street,under bc 330
Sep 8, 2017 · Penalty $400
Resolve - Class - 2
Work does not conform to plans.at time of inspection noted that jobsite foundation has not been removed as per demolition plans sequence at expo#1,2,3 and partial #4 and with egress ladder in place @ expo#2
Mar 23, 2017 · Penalty $500
Resolve - Class - 1
Work does not conform to apporved const documents. at time of inspection noted @ exposure #4 of adjoining propery the required 1/2' 12'x 12'flat screen plate where not installed as perm plan or tie back of adjo
Mar 23, 2017 · Penalty $1,000
Resolve - Class - 2
Project information panel/sidewalk shed parapet panel construction sign not provided or not in compliance w.section.noted:@time of inspection sidewalk shed has no sign that compliance w.section.sign is missing
Oct 3, 2016
Resolve - Class - 1
Failure to maintain bldg in a code compliant manner. noted: roof removed leaving structure exposed. rem: make safe immediately- repairs maintain.
Aug 2, 2016 · Penalty $1,000
Resolve
Complaints
No HPD complaints in our records
Sales history
No recorded sales in our data
Building details
- Building type
- Mixed residential and retail building (S9)
- Year built
- 2019
- Floors
- 6
- Residential units
- 2
- Building area
- 6,935 ft²
- Lot area
- 1,151 ft²
- Zoning
- C6-2
- Community board
- 103
- Council district
- 1
- Block / lot
- 310 / 20
- Assessed value
- $1,815,300
- Landmark / historic district
- No
Questions about 355 Grand Street
Who owns 355 Grand Street?
The owner of record in NYC Department of City Planning PLUTO data is Interboro Realty Management Corp..
Does 355 Grand Street have violations?
NYC HPD has no housing violations on record for this property.
Is 355 Grand Street rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 355 Grand Street built?
City records list 2019 as the year it was built.
How many apartments are in 355 Grand Street?
It has 2 residential units and 4 units in total.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.