roofy

29-31 Leonard Street

Manhattan, NY 10013BBL 1-00179-0043Map

Owner of record: 31 Leonard Street, LLC

29-31 Leonard Street is an elevator apartment building built in 1881 in Manhattan, 10013. It has 11 residential units across 7 floors. The owner of record is 31 Leonard Street, LLC. HPD has no housing violations on record for this property.

HPD violations
0
DOB violations
0
ECB violations
32
HPD complaints
0

What to know

Good
No open Class C

No open immediately-hazardous violations among recent records.

Good
No HPD violations

HPD has not cited this building.

Good
No unpaid ECB fines

No balance due on recent ECB violations.

Rent stabilization

No rent-stabilized units in 2018–2024 tax bills

Some apartments can still be regulated. Use the rent-stabilized checker or request the rent history from HCR.

Violations

Most recent first. Showing up to 50 per agency.

HPD housing violations · 0

No HPD violations on record

DOB building violations · 0

No DOB violations on record

ECB violations · 32

  • Class - 2

    At time of inspection an active 7-story alt 1 jobsite, i observed there were tie-backs at the wall of exp.#4, upon request for details of the tie-backs approved by dob, the approved drawings provided doesn't ha

    May 4, 2023

    Resolve
  • Class - 2

    At time of inspection an active 7-story alt 1 jobsite, i observed two columns at exp#1 close to exp.#4 were none plumbing to the ground level, i also observed the beam above these two columns horizontally moved

    May 4, 2023 · Penalty $5,000

    Resolve
  • Class - 1

    Time of inspection observed at exposure 2 from the top of the bulkhead , work on top of bulkhead is not complete, the adjacent property with no roof protection, to avoid damage while installing coping at the to

    Mar 20, 2023 · Penalty $625

    Resolve
  • Class - 2

    At time of inspection of a 7 story alteration, upon request to view the 6month periodic 6 month inspection for the sidewalk shed at exposures 1 and 4, no 6 month inspection letter was provided. six months follo

    Mar 20, 2023

    Resolve
  • Class - 2

    Time of inspection observed at exposure 1, plastic barricades not filled with water as per manufacturers specifications to add weight to the plastic barricades. plastic barricades at exposure 1 with cyclone fe

    Mar 20, 2023

    Resolve
  • Class - 2

    Failure to submit acceptable required cycle 9a report of critical examination documenting condition of exterior wall & appurtenances required by 28-302.4 for control #900398.remedy:submit acceptable required te

    Dec 2, 2022

    Resolve
  • Class - 2

    At the time of inspection, i observed that the adjoining recreation space at expo#3 did not have an overhead protection or an established and maintained control access zone (caz) during active construction. st

    Oct 13, 2022

    Resolve
  • Class - 1

    No design drawing for ssp

    Aug 15, 2022

    Resolve
  • Class - 2

    Failure to maintain exterior facade&appurtenances atoi observed vert crack&spalled coating@multiple locations@e elevation,exp4 w/o any safety measures.maintain exterior facade,provide safety measures,repair dam

    Jul 13, 2022

    Resolve
  • Class - 2

    Bc 3303.7.2(empty and inadequate fire extinguishers)at the time of inspection i observed 7 story building with work activity present.it was also observed that the contractor failed to have full and adequate ext

    Jun 3, 2022

    Resolve
Show 22 more ↓
  • Class - 2

    Failure to maintain/display onsite documents required by bc chapter 33(makeshift elevator shaft platforms)at time of inspection i observed 7story building with work actively present.it was also observed that th

    Jun 3, 2022

    Resolve
  • Class - 2

    Work does not conform to approved construction documents and/or approved amendments.at the time of inspection i observed 7 story building with work activity present.it was also observed contractor failed to ins

    Jun 3, 2022 · Penalty $1,250

    Resolve
  • Class - 1

    Bc3306.9.12.1 protection of fl openings.atoi i observed proposed alt to 7styb w/work activity present.i also observed multiple unsecured hole covering in various locations on multiple fls thruout bldg,presentin

    Jun 3, 2022 · Penalty $625

    Resolve
  • Class - 1

    Contractors engaged in bldg construction shall institute & maintain all safety measures & safety equipment-stop all work on entire site provided proper egress into site no stair at exp.#1 24 inch step into site

    Oct 20, 2021 · Penalty $625

    Resolve
  • Class - 1

    Bc3307.4.7 where work or storage relating to the construction of a bldg adjacent to a sidewalk shed a solid barrier 4ft in height w/wire mesh panel to the bottom of the sidewalk shed-stop all use of work & stor

    Oct 20, 2021 · Penalty $625

    Resolve
  • Class - 1

    Work does not conform to approved construction documents stop all workconform site safety plan to work being done w/in the construction site-call c.s.e for re-inspection.note:at the time of my inspection of a 7

    Oct 20, 2021 · Penalty $625

    Resolve
  • Class - 1

    Work does not conform to approved construction documents needle beams installed at expo#3 needs it's own general plan for details of the needle beams.note:at the time of my inspection of a 7 story bldg under an

    Oct 20, 2021 · Penalty $625

    Resolve
  • Class - 2

    Failure to post all permits for work on premises.note:at the time of my inspection of a 7 story bldg under an alt under construction,an active job site i observed on the construction fence at exp.#1 has no dio.

    Oct 20, 2021

    Resolve
  • Class - 2

    Scaffold training certificate card not readily available for inspection-provided means & methods to ensure all worker have training.note:at the time of inspection of a 7 story bldg under an alt under constructi

    Oct 20, 2021

    Resolve
  • Class - 1

    Failue to maintain adequate housekeeping-stop all work on supported scaffolding at exp.#1-clean all decks from concrete debris-call cse for re-inspections.note:at the time of my inspection of a 1 story bldg und

    Oct 20, 2021 · Penalty $625

    Resolve
  • Class - 2

    Temporary construction equipment on site expired permit stand pipe installation.permit expired on 02/12/2021.note:at the time of my inspection of a 7 story bldg under an alt under construction,an active job sit

    Oct 20, 2021

    Resolve
  • Class - 1

    Standpipes must be always in the state of readiness permanent or temporary standpipe systems painted red.note:at the time of my inspection of a 7 story bldg under an alt under construction,an active job site i

    Oct 20, 2021 · Penalty $2,500

    Resolve
  • Class - 1

    Permit holder failed to maintain the dailt log idetifying each worker and copy of the sst card supervisor sst card.at the time of inspectionobserved curtis thanville,carlos ali,marcel antonie and a couple of wo

    Jul 8, 2021 · Penalty $2,500

    Resolve
  • Class - 2

    Bc3301.6.1 no design drawing noted:atoi of active jobsite.observed@st level ibeams attached to truck&attached to@grndfl level@exp1 column w/trolley attached to system to bring material inside site&1pully system

    Jun 21, 2021

    Resolve
  • Class - 1

    3301.2 control access zone.noted at time of inspection at an active jobsite.observed metal stair install at 2fl to 3fl steel deck with opening no form of protection in place to prevent worker's from accessing t

    Jun 21, 2021 · Penalty $625

    Resolve
  • Class - 2

    Failure to maintain adequate housekeeping per section requirements.noted at time of inspection at an active jobsite.observed at cellar levelblack garbage with garbage pile up in front the stair at cellar level.

    Jun 21, 2021

    Resolve
  • Class - 2

    Construction superintendent failed to perform duties per code.noted attime of inspection at an active jobsite.upon reviewing the construction superintendent logs observed no time in/out was recorded in the logs

    Jun 21, 2021 · Penalty $2,500

    Resolve
  • Class - 1

    Failure to maintain/display onsite documents required by bc chapter 33noted at time of inspection at an active jobsite.upon request to the preshift meeting toolbox take site specific orientation for each worker

    Jun 21, 2021 · Penalty $1,250

    Resolve
  • Class - 1

    Failure to institute/maintain safety equipment measures or temporary construction.noted at time of inspecyion at an active jobsite,observed from bottom floor-cellar stairwell installed where the work use to pro

    Jun 21, 2021 · Penalty $2,500

    Resolve
  • Class - 1

    3303.7.2 fire extinguisher.noted at time of inspection of an active jobsite.observed cellar to 4th floor where work is take place no fire extinguisher distribute on floor as per fire code.remedy:comply with nyc

    Jun 21, 2021 · Penalty $2,500

    Resolve
  • Class - 1

    Failure to maintain/display on site docs required by bc ch 33.at time of inspection requested the following docs which were not provided:site safety plan,sidewalk shed inspection reports,supported scaffold insp

    Sep 30, 2020 · Penalty $1,250

    Resolve
  • Class - 1

    Provision of law:bc3301.6.design drawings.at time of inspection observed a temporary platform at expo#1 being used w/ heavy equipment driving on top of it.also observed a temp platform at expo#3 that leads to t

    Sep 30, 2020 · Penalty $625

    Resolve

Complaints

No HPD complaints in our records

Complaint data is still being backfilled from NYC Open Data.

Sales history

No recorded sales in our data

Sales come from the NYC Department of Finance rolling sales file.

Building details

Building type
Elevator apartment building (D7)
Year built
1881
Floors
7
Residential units
11
Building area
31,262 ft²
Lot area
5,310 ft²
Zoning
C6-2A
Community board
101
Council district
1
Block / lot
179 / 43
Assessed value
$3,315,600
Landmark / historic district
Tribeca West Historic District

Questions about 29-31 Leonard Street

Who owns 29-31 Leonard Street?

The owner of record in NYC Department of City Planning PLUTO data is 31 Leonard Street, LLC.

Does 29-31 Leonard Street have violations?

NYC HPD has no housing violations on record for this property.

Is 29-31 Leonard Street rent stabilized?

No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.

When was 29-31 Leonard Street built?

City records list 1881 as the year it was built.

How many apartments are in 29-31 Leonard Street?

It has 11 residential units and 13 units in total.

Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.