253 Broadway
Manhattan, NY 10007BBL 1-00134-7501Map
Owner of record: NYC Department Of Citywide Administrative Services
253 Broadway is a condominium built in 1894 in Manhattan, 10007. The owner of record is NYC Department Of Citywide Administrative Services. HPD has no housing violations on record for this property.
- HPD violations
- 0
- DOB violations
- 137
- ECB violations
- 117
- HPD complaints
- 5
What to know
No open immediately-hazardous violations among recent records.
HPD has not cited this building.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 0
No HPD violations on record
DOB building violations · 137
- Construction other optional
Failure to maintain building in code compliant manner. as noted: at time of inspection i observed on exposure#3 west elevation: spalled damage bricks and water table coping stone at the 17th floor. remedy: repair and/or replace all damaged masonry on facade
May 7, 2025
Dob violation - active - Hazardous condition (facade) facade required
Cycle 9a unsafe report filed
Dec 5, 2023
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Oct 4, 2023
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Oct 4, 2023
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Oct 4, 2023
Dob violation - dismissed - Landmark none
Landmk-landmark none
Feb 2, 2023
Dob violation - dismissed - No report and / or late filing (facade) facade required
Failed to file fisp cycle 9a technical report by 02/21/2022
Feb 22, 2022
Dob violation - dismissed - Plumbing none
Borough commissioner has issued a notice of immediate stop work order due to applicant withdrawal of application #140811209 as of 11/26/2021
Nov 26, 2021
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Mar 1, 2021
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Mar 4, 2020
Dob violation - resolved
Show 40 more ↓
- Sprinkler none
Failed to file final sprinkler report by july 1, 2019
Sep 3, 2019
Dob violation - active - Elevator elevatorrequired
E-elevator elevatorrequired
Jun 4, 2019
Dob violation - resolved - No report and / or late filing (facade) facade required
Failed to file fisp cycle 8a technical report by 02/21/2017
May 31, 2018
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Mar 13, 2018
Dob violation - resolved - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2016 inspection/test
Sep 15, 2017
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Feb 2, 2017
Dob violation - active - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2015 inspection/test
Dec 1, 2016
Dob violation - dismissed - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2015 inspection/test
Dec 1, 2016
Dob violation - dismissed - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2015 inspection/test
Dec 1, 2016
Dob violation - dismissed - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2015 inspection/test
Dec 1, 2016
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Nov 2, 2016
Dob violation - active - Elevator elevatorrequired
E-elevator elevatorrequired
Nov 2, 2016
Dob violation - resolved - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Oct 5, 2016
Dob violation - dismissed - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Aug 2, 2016
Dob violation - active - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
Jun 2, 2016
Dob violation - active - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 12, 2016
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 12, 2016
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 12, 2016
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 12, 2016
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 12, 2016
Dob violation - resolved - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Dec 30, 2015
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2012 cat 1 insp/tst
May 30, 2014
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2012 cat 1 insp/tst
May 30, 2014
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2012 cat 1 insp/tst
May 30, 2014
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2012 cat 1 insp/tst
May 30, 2014
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2012 cat 1 insp/tst
May 30, 2014
Dob violation - dismissed - Elevator affirmation of correction elevatorrequired
Vio issued to elevator - fail to correct defects on 2012 cat 1 insp/tst
May 30, 2014
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jan 15, 2014
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jan 15, 2014
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jan 15, 2014
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jan 15, 2014
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jan 15, 2014
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jan 15, 2014
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Jan 15, 2014
Dob violation - dismissed - Construction other optional
C-construction other optional
Jul 31, 2013
Dob violation - dismissed - No report and / or late filing (facade) facade required
Failed to file fisp cycle 7a technical report by 02/21/2012
Jan 31, 2013
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Oct 17, 2012
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Oct 16, 2012
Dob violation - resolved - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Oct 3, 2012
Dob violation - dismissed - Fail to certify class 1 none
Failure to certify correction on immediately hazardous (class 1) ecb violation
Oct 3, 2012
Dob violation - dismissed
ECB violations · 117
- Class - 2
Failed to provide sidewalk shed parapet information panel contrary with bc-3301.9.2, creating hazardous for fdny in emergency to easy located the site. where a sidewalk shed is installed, a sidewalk shed parape
Oct 4, 2024 · Penalty $1,280
Active - Class - 1
Observed improper installation of. horizontal tieback. which? show me perpendicular to the face of the building. or. structure. or opposing angles. tieback show be installed single tieback installed at an angle
May 17, 2023 · Penalty $625
Resolve - Class - 2
Suspended scaffold in place and i use with the following. objections. 1500 pound. motors. installed and in use,cd5 indicate. 1000 pound. maximum load. missing counterweight, mission details. for tiebacks at do
May 17, 2023
Resolve - Class - 1
Suspended scaffold does not meet building code specification. note. at time of inspection. life lines and tie backs were secured to the same point of anchorage. all lines. and tie backs to be separate from. one
May 17, 2023 · Penalty $625
Resolve - Class - 2
Span of i-beam set up non-conforming, .missing additional tiebacks, not perpendicular to the face of building cross braces not installed into pipe frame, counterweights not secured to the system.rolling gantry,
May 17, 2023
Resolve - Class - 1
Suspended scaffolds in use at. exposures 1/2. and 4 the following. objections, responsibilities. of license rigger for work involving the use of suspended scaffolds. or other. rigging setups, where clamps are u
May 17, 2023 · Penalty $625
Resolve - Class - 1
I observe. parapet clamps in place with no bearing blocks. in place which should be in place to secure against movement or dislodgment. suspended scaffolding in usecomply with code. do not use or remove suspend
May 17, 2023 · Penalty $625
Resolve - Class - 1
Observed tie backs and parapet clamps not vertical or parallel to wall ,all hanging /suspended equipment shall be vertical /parallel to the surface/wall it rest uponcomply with code.do not remove or suspended
May 17, 2023 · Penalty $625
Resolve - Class - 2
All wire ropes used in hoisting equipment shall meet the inspection and replacement requirements specified in rules promulgated by and described. by rule of that department.replace and remove
May 17, 2023 · Penalty $625
Resolve - Class - 2
Wire rope clips. when wire clips are used on suspended scaffolds their she'll be a minimum 3 wire ropes clips a minimum of 6 rope in diameters apart. to prevent shafting. or movement. installation of wire clips
May 17, 2023
Resolve
Show 40 more ↓
- Class - 1
Observe suspend scaffolds in use and life lines on suspend that were in use. not protected. a point of contact that includes. parapet wall rooftop, and at exposures 3. stop all work. and remove ropes in use pro
May 17, 2023 · Penalty $2,500
Resolve - Class - 2
Observe. inadequately maintained fire extinguishers throughout the construction site, fire extinguishers. were placed on the floor. inspection service not up to date. and not charged.service and maintain fire e
May 17, 2023 · Penalty $1,280
Resolve - Class - 1
I observe suspend scaffolds in use and life lines on suspend that were in use. not protected. at point of contact that includes. parapet wall rooftop, and at exposures 1/2 and 3. stop all work. and remove ropes
May 17, 2023 · Penalty $625
Resolve - Class - 1
Observe suspended scaffolds. in connection with outrigger beams. erected i'd exposures one and 2. stirrups are placed at. 5 feet to 6 feet. from the end of the modular platform. which does not meet. code specif
May 17, 2023 · Penalty $625
Resolve - Class - 1
Observed. suspend the scaffolds in use with no manufacture specs provided for remote control/pendent. styrofoam. c-stirrup. none was provided creating a hazardous condition for personnel workers using. suspende
May 17, 2023 · Penalty $625
Resolve - Class - 1
Life lines and tie backs were secured to the same point of anchorage. all lines. and tie backs to be separate from. one another, to different point of anchorage.do not use do not remove suspended scaffolds allo
May 17, 2023 · Penalty $2,500
Resolve - Class - 1
Suspend the scaffolds in use with no manufacture specs provided for remote control/pendent. c-stirrup on motor north east rated for 1k,motors in place rated 1500,missing platform size . none was provided creati
May 17, 2023 · Penalty $2,500
Resolve - Class - 2
At time of inspection i observed sidewalk shed in place. without project information panel sidewalk shed parapet and construction sign not providedcomply with code
May 17, 2023 · Penalty $1,280
Resolve - Class - 2
Upon reviewing approved engineer design drawings for corner / angle suspended scaffolding system it was discovered that no detail was provided for the tie back for outrigger beam at an angle current install ref
May 5, 2023 · Penalty $1,280
Resolve - Class - 2
At time of inspection on a 17 story facade restoration job angle / corner suspended scaffolding system is being used at exposure 4 of the building fully installed and in use with no pre inspection on file or co
May 5, 2023 · Penalty $1,280
Resolve - Class - 2
Observed 2 suspended scaffold platforms at exp#4 left suspended at rf lvl when not in use. during an inspection on 03/22/23, workers were instructed to bring the platforms down, and the rigger/respondent was co
Mar 28, 2023
Resolve - Class - 2
Observed suspended scaffolds (outrigger beam w/ counter-weights) erected and ready for use at exp#1&2). the department was not notified by the rigger currently responsible for the equipment prior to the install
Mar 22, 2023 · Penalty $1,250
Resolve - Class - 2
Observed a corner angle 4-point suspended scaffold at exp#4- in use. the scaffold was suspended on 4 outrigger beams. upon review of the dob-approved plans/drawings, i found that they only called for 3 outrigge
Mar 22, 2023
Resolve - Class - 2
Observed outrigger beams (w/ counter-weights) at exp#1,2- upon review of the provided cd-5, i found that no plans, details, sections were included in the package. observed outrigger beams at exp#4 on top of mod
Mar 22, 2023
Resolve - Class - 2
Observed a 4-point corner-angle suspended scaffold at exp#4- in use. upon speaking with the site safety manager and upon review of department records, i found that the scaffold in question was not inspected by
Mar 22, 2023 · Penalty $625
Resolve - Class - 2
Failure to submit acceptable required cycle7a,8a,9a report of criticalexam documenting condition of exterior wall&appurtenances required by 28-302.4 for control900319.submit acceptable req technical report
Dec 2, 2022 · Penalty $1,250
Resolve - Class - 2
3309.10 no roof protection expo 4 at time of inspection at a 17 story alteration,i observed suspended scaffold erected to roof level expo 4 (approx 3 platforms)without roof protection adjacent property)building
Mar 2, 2022 · Penalty $1,280
Resolve - Class - 2
Work does not conform to approved construction documents and/or amendments-hanging rigs plans(north). at time of inspection at a 17 story alteration,i observed suspended scaffold platform and outriggers in plac
Mar 2, 2022
Resolve - Class - 2
Work does not conform to approved construction documents &/or approvedamendments-contrary to approved supported scaffold drawings. at the time of inspection,i saw 17 sty's bldg under facade repairs & working on
Aug 18, 2021
Resolve - Class - 2
Failure to provide approved/accepted construction documents at job site at the time of inspection. no approved cds at site. at the time of inspection,i observed facade work in progress at exp#1,worker working i
Aug 18, 2021 · Penalty $625
Resolve - Class - 2
34r8: 34-r-8 hoistway fire wires need to be removed as per 1rcny 11-02. [email protected]. call 212 393 2435
Dec 27, 2019 · Penalty $625
Resolve - Class - 2
Sec. 27-929.1 a.c.27-929.1,failure to complete the installation of a full system of automatic sprinklers& file a final sprinkler report prepared by a registered design professional by 7/1/19,in an office bldg
Nov 15, 2019 · Penalty $1,250
Active - Class - 2
Failure to submit acceptable 8th round report of critical examination documenting condition of exterior walls & appurtenances required by 28-302.4 for control #800319.rem:submit required technical report.
May 18, 2018
Resolve - Class - 2
Bc3307.6.5.11/failure to notify the department prior to removal of construction equipment.note:at time of inspection observed sidewalk shed in place provided by a different construction company as per managemen
Aug 22, 2017
Resolve - Class - 1
Fail to take required measures to secure public saety.unsafe facade. east elev exp1 southeastern section 4 floor to the left of the american flag decorative trim is dislodged, loose and grount has debonded.rmd
Jun 20, 2017
Resolve - Class - 2
Failure to maintain exterior bldg roof-southside exit onto roof southwall defective exposed steel iii stairwell b bulkhead stucco cracked & cracking. roof ph(single story)stucco cracked & broken. east elev exp#
Jul 21, 2016
Resolve - Class - 2
Failure to file an acceptable technical report in compliance w/code provisions:periodic insp of exterior walls & appurtenances as required by article 28.302 & the dob rules & regulations.rem:file the required r
Sep 21, 2015
Resolve - Class - 2
Failure to file an acceptable amended cycle 6 report to this dept indicating correction of unsafe conditions described in initial local law fisp report. remedy: file an amended report following remedial repair
Aug 17, 2015
Resolve - Class - 2
Failure to maintain bldg walls & appurtenances. noted: (i) at exposure 1 (broadway) spalled masonry was found by & near top of 4/f windows; (ii) defective roof guard railing was found at upper roof at south e
Jun 19, 2015
Resolve - Class - 2
Removal of sidewalk sheds without dept's approval. noted: at time of inspection, building facade were still designated as "unsafe". the amended report (tr6), received on 05/13/15, had not been accepted & safety
Jun 19, 2015
Resolve - Class - 1
Failure to take & provide safety measures (sidewalk shed/netting) where required to protect & secure public safety from documented unsafe facade as per 1 rcny 103-04. -facade technical report filed unsafe by pe
Jan 16, 2015
Resolve - Class - 2
Failure to file an acceptable cycle 7 technical report in compliance with code provisions: periodic inspection of exterior walls & appurtenances as required by article 28-302 & the dept of bldgs rules & regulat
Apr 9, 2014
Resolve - Class - 1
Sec. 3310.5 failure to have site safety manager or coodinator present as required. noted: some workers on 2nd fl others on top floors - fulltime site safety required - no site safety manager at time 11am.
Sep 5, 2013 · Penalty $400
Resolve - Class - 1
100x10- wheelchair lift safety switches were not working - (cease use)call dob before returning back to service - 212.566.5542. (cease use) as per supervisory admin office.
Oct 19, 2012
Resolve - Class - 2
Bc3301.2 failure to safeguard all persons & property affected by construction operations noted at time of insp in light well shaft #2 pipe scaffold erected 4th floor to roof for brick & window replacement prote
Jul 19, 2012 · Penalty $1,200
Resolve - Class - 1
Work does not conform to approved construction documents &/or approvedamendments. noted at time of inspection scaffold erected in light well 2 from 4 flr to roof permit 12038934701eqsf indicates 5 platforms wit
Jul 19, 2012 · Penalty $1,000
Resolve - Class - 1
(electrical work w/o a permit for material lift) the respondent failedto obtain an electrical permit for the connection of a material lift. installed on the roof. no permit for this work was posted at the site.
Jul 3, 2012 · Penalty $1,600
Resolve - Class - 1
(failure to provide proper support for temporary wiring) the respondent installed temporary wiring for a sidewalk shed w/o proper support orproper electrical materials to support an electrical feeder. to extend
Jul 3, 2012 · Penalty $8,000
Resolve - Class - 1
Work does not conform to approved construction documents or approved amendments. at time of inspection sidewalk shed not constructed to approved drawings observed a section of sidewalk shed at approx 12'-0" in
Jul 3, 2012 · Penalty $250
Resolve - Class - 2
Supported scaffolds @ roof level does not conform to approved plans.noted:chain pully installed @ top of the scaffolds without design plans from pe.pictures dated.stop all work on supposted scaffolds,except to
Jul 3, 2012
Resolve
Complaints
- Heat/hot water
Apartment only
Jan 5, 2021 · Apt 23
Close - Heat/hot water
Apartment only
Nov 22, 2020 · Apt 23
Close - Unsanitary condition
Garbage/recycling storage
Jul 14, 2018 · Apt BLDG
Close - Heating
Heat related
Nov 10, 2013 · Apt NA
Close - Heating
Heat related
Nov 8, 2013 · Apt NA
Close
Sales history
No recorded sales in our data
Building details
- Building type
- Condominium (RC)
- Year built
- 1894
- Floors
- 15
- Residential units
- —
- Building area
- 267,438 ft²
- Lot area
- 18,800 ft²
- Zoning
- C5-3
- Community board
- 101
- Council district
- 1
- Block / lot
- 134 / 7501
- Assessed value
- $23,361,396
- Landmark / historic district
- INDIVIDUAL LANDMARK
Questions about 253 Broadway
Who owns 253 Broadway?
The owner of record in NYC Department of City Planning PLUTO data is NYC Department Of Citywide Administrative Services.
Does 253 Broadway have violations?
NYC HPD has no housing violations on record for this property.
Is 253 Broadway rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 253 Broadway built?
City records list 1894 as the year it was built.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.