4 Platt Street
Manhattan, NY 10038BBL 1-00069-0030Map
Owner of record: Lam Platt Street Hotel LLC
4 Platt Street is a hotel built in 2012 in Manhattan, 10038. The owner of record is Lam Platt Street Hotel LLC. HPD has recorded 3 housing violations here, most recently on March 31, 2023.
- HPD violations
- 3
- DOB violations
- 57
- ECB violations
- 27
- HPD complaints
- 5
What to know
No open immediately-hazardous violations among recent records.
Date of the most recent HPD inspection that found a problem.
No balance due on recent ECB violations.
Rent stabilization
No rent-stabilized units in 2018–2024 tax bills
Violations
Most recent first. Showing up to 50 per agency.
HPD housing violations · 3
- ANon-hazardous
File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.
Mar 31, 2023
Closed — Violation dismissed - IInformation / order
And is therefore subject to civil penalties, prohibited from certifying violations, and denied the right to recover possession of premises for nonpayment of rent until a valid registration statement is filed.
Nov 3, 2022
Closed — Violation dismissed - ANon-hazardous
File annual bedbug report in accordance with hpd rule as described on the back of this notice of violation or as described on hpds website, www.nyc.gov\hpd, search bed bugs.
Apr 20, 2021
Closed — Violation dismissed
DOB building violations · 57
- Low pressure boiler boiler required
Violation issued-failure to file 2020 external low pressure inspection
Jun 30, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2020 external low pressure inspection
Jun 30, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2020 external low pressure inspection
Jun 30, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2020 external low pressure inspection
Jun 30, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2021 external low pressure inspection
Jun 30, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2021 external low pressure inspection
Jun 30, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2021 external low pressure inspection
Jun 30, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2021 external low pressure inspection
Jun 30, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2018 external low pressure inspection
Jun 20, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2018 external low pressure inspection
Jun 20, 2023
Dob violation - active
Show 40 more ↓
- Low pressure boiler boiler required
Violation issued-failure to file 2018 external low pressure inspection
Jun 20, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2018 external low pressure inspection
Jun 20, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2019 external low pressure inspection
Jun 20, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2019 external low pressure inspection
Jun 20, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2019 external low pressure inspection
Jun 20, 2023
Dob violation - active - Low pressure boiler boiler required
Violation issued-failure to file 2019 external low pressure inspection
Jun 20, 2023
Dob violation - active - Failure to benchmark none
Failure to file benchmarking report of energy use as per ad. code sec. 28-309.4
May 2, 2023
Dob violation - active - Construction other optional
Vio22-50084
May 23, 2022
Dob violation - active - No report and / or late filing (facade) facade required
Failed to file fisp cycle 9a technical report by 02/21/2022
Feb 22, 2022
Dob violation - active - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 16, 2021
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 16, 2021
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 16, 2021
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 15, 2020
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 15, 2020
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 15, 2020
Dob violation - resolved - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2017 inspection report
Jan 17, 2020
Dob violation - active - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2017 inspection report
Jan 17, 2020
Dob violation - active - Low pressure boiler boiler required
Violation issued for failure to file annual boiler 2017 inspection report
Jan 17, 2020
Dob violation - active - Elevator annual inspection / test elevatorrequired
Violation issued to elevator - failure to file category 1 2017 inspection/test
Apr 5, 2019
Dob violation - dismissed - Elevator annual inspection / test elevatorrequired
Violation issued to elevator - failure to file category 1 2017 inspection/test
Apr 5, 2019
Dob violation - dismissed - Elevator annual inspection / test elevatorrequired
Violation issued to elevator - failure to file category 1 2017 inspection/test
Apr 5, 2019
Dob violation - dismissed - Elevator annual inspection / test elevatorrequired
Violation issued to elevator - failure to file category 1 2017 inspection/test
Apr 5, 2019
Dob violation - dismissed - Elevator annual inspection / test elevatorrequired
Violation issued to elevator - failure to file category 1 2017 inspection/test
Apr 5, 2019
Dob violation - dismissed - Elevator elevatorrequired
Cease use
Feb 25, 2019
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 25, 2019
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 13, 2018
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 13, 2018
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 13, 2018
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 13, 2018
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 13, 2018
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 16, 2017
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 16, 2017
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 16, 2017
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 15, 2017
Dob violation - resolved - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 15, 2017
Dob violation - resolved - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2015 inspection/test
Dec 1, 2016
Dob violation - dismissed - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2015 inspection/test
Dec 1, 2016
Dob violation - dismissed - Elevator annual inspection / test elevatorrequired
Violation issued to elevator-failure to file category 1 2015 inspection/test
Dec 1, 2016
Dob violation - dismissed - Residential elevator periodic inspection/test elevatorrequired
Failure to perform category 5 inspection
Jun 1, 2016
Dob violation - dismissed - Elevator elevatorrequired
E-elevator elevatorrequired
Feb 4, 2016
Dob violation - resolved
ECB violations · 27
- Class - 3
Failure to post building exterior wall condition certificate as required under 1rcny 103-04.note:certificate was not posted in lobby or any conspicuous location.remedy:post building exterior wall certificate
Feb 2, 2023 · Penalty $500
Resolve - Class - 2
Failure to submit an acceptable required cycle 9a report of critical examination documenting condition of exterior wall and appurtenances required by 28-302.4 for control#917301.rem:917301.rem:submit acceptable
Dec 9, 2022 · Penalty $1,250
Resolve - Class - 1
Failure to safeguard all persons & property affected by construction operations.noted work taking place on the 17th fl east side section of bldg where masonry taking place.a vehicle was struck w/ cement motor c
May 1, 2015 · Penalty $12,000
Active - Class - 2
Failure to comply w/the commissioner's order to file a c of c w/the dept of buildings for notice of violation #35097026j issued on 9/13/14 pursuant to 28-204.4 & 1rcny 102-01. for failure to have site safety
Oct 30, 2014 · Penalty $400
Resolve - Class - 1
Failure to have site safety manager or coordinator present as requirednoted: at time of inspection observed 2 laborers working on elevator pit of 1st floor with no site safety manager present on site as requir
Sep 13, 2014 · Penalty $1,200
Resolve - Class - 1
Sec. 3310.8.3 failure to comply w/approved plans & application. note: at the time of my inspection construction work in progress. it was brought to my attention that site safety manager #899 is responsible for
Jul 24, 2014 · Penalty $800
Resolve - Class - 2
Sec. 3310.6 designated site safety manager. note: at the time of inspection construction work in progress,review of site safety logs reveal that site safety manager #899 was performing duties since 7-7-14 to
Jul 24, 2014 · Penalty $400
Resolve - Class - 1
3303.1.2 service line & conduit constitute a tripping hazard. @time of insp noted that a welding line was being used on the 26th flr runningdown to the 5th flr thru the door accross the stairs into the hall's.t
Jul 17, 2014 · Penalty $1,600
Resolve - Class - 1
Failure to safeguard persons and prop affected by const operations.@ time of insp noted that on the rooftop of bldg the are const materials @ expo 1 & 2 not straped down,plywood,duckvent tin,alc that can potenc
Jul 17, 2014 · Penalty $2,400
Resolve - Class - 1
Failure to maintain adequate housekeeping per section requirements.@ time of insp noted that the site has several areas that need housekeeping all the halls from 27 to 1st fl including removal of planking on st
Jul 17, 2014 · Penalty $2,400
Resolve
Show 17 more ↓
- Class - 1
Failure to provide unobstructed exit passageway.@ time of insp noted that the ingress & egress pasage from the elev to the stairs was obstructed by doors,sheetrock,trash bins ladders @ several loc throughout th
Jul 17, 2014 · Penalty $1,200
Resolve - Class - 2
Partial swo issued for suspended scaffold pursuant 28-207.2 & posted on premises.work does not conform to approved plans noted at time of inspec.material h oist attached to the same scaffold frame as outrigger
May 13, 2014 · Penalty $2,500
Resolve - Class - 1
Failure to maintain adequate housekeeping per section requirements. attime of inspection observed active jobsite - interior trades working throughout site. at time of inspection observed multiple piles of debri
Mar 11, 2014 · Penalty $400
Resolve - Class - 1
Sec. 3301.2;27-1009(a) holes/openings not covered. at time of inspection observed active jobsite,interior trades working throughout - exterior trades working on exposure 1. at time of the inspection i observed
Mar 11, 2014 · Penalty $1,600
Resolve - Class - 1
Work w/o a permit. at the time of inspection observed nb building under permit no. 120630825 using water from the fire hydrant on platt str.hose was connected to the hydrant. approach to see the permit. invalid
Feb 1, 2014
Resolve - Class - 1
Failure to safeguard all persins & property affected by construction ops. at time of inspection observed active jobsite. sidewalk shed beingremoved on pearl st. location of jobsite. contractor has sidewalk clos
Jan 6, 2014
Resolve - Class - 2
Work does not conform to approved construction documents and/or approved amendments. noted: at time of inspection anchors for outrigger beams, tiebacks are approx 4" x 4" when cd-5 plans show 10" x 5" at exp #1
Dec 17, 2013
Resolve - Class - 1
Use of supported scaffold w/o a scaffold user certificate. noted: at time of inspection following workers: 1. leonel valencia. 2. fabian erraez working on supported scaffolds at exp #4 w/o a scaffold user cert
Dec 17, 2013 · Penalty $400
Resolve - Class - 2
Jobsite fence not constructed or maintained pursuant to subsection. noted: construction site fence is painted light blue, does not have viewing panels, what's going on here sign posted on exposure 1,south si
Sep 24, 2013
Resolve - Class - 1
Bc3318.9 97## -cease use device #iv22794.replace cat head,replace damaged lacing & rewelded lacing.replace cwt rails that are twisted and damaged,replace cut rollers pins & bearings.provide proper running clear
Jul 18, 2013 · Penalty $1,200
Resolve - Class - 1
97## -illegal operation of personal hoist,upon arrival found hoist # iv22793 being operational by multiple job site personal.
Jul 18, 2013 · Penalty $1,600
Resolve - Class - 1
Bc3318.9 97## -cease use device #iv22793.replace cat head,replace damaged lacing & rewelded lacing.replace cwt rails that are twisted and damaged,replace cut rollers pins & bearings.provide proper running clear
Jul 18, 2013 · Penalty $1,200
Resolve - Class - 2
Failure to post permit for sidewalk closing. note at time of inspection observed. (2) workers directing pedestrian across the street from front of construction site which should be open to pedestrian on pearl
Mar 25, 2013
Resolve - Class - 2
Work w/o a permit. note power is being supply from 2 gold street to 6 platts for lighting of stairway & energizing alarm system installed atat basement level w/o obtain a permit for temporary power. stop all
Feb 20, 2013
Resolve - Class - 1
3310.8.2 site safety mgr failed to immediately notify the dept of conditions as req.note:site safety mgr didn't notify dept once bldg reached height of 75' & standpipe not in readiness after working hrs(5pm-7am
Feb 14, 2013
Resolve - Class - 1
1704.22.1.1 partial *swo* fail to file op 98 for hydrostatic test.note:work in progress.bldg complete to 10 stories.standpipe up to 8 stories as per dob record no op 98 has been filed.*stop all work above 75'*
Feb 14, 2013 · Penalty $1,600
Resolve - Class - 2
Sec. 28-116.2.3. failure to provide an adequate inspection program noted: at time of inspection concrete for foundation has been partially placed along exps 3 & 4 forming walls for elevator pit. tr2 - concrete
Aug 10, 2012 · Penalty $400
Resolve
Complaints
- Unsanitary condition
Pests
Jun 12, 2022 · Apt 1206
Close - Unsanitary condition
Pests
Dec 29, 2021 · Apt 1001
Close - Unsanitary condition
Pests
May 16, 2021 · Apt 1402
Close - Unsanitary condition
Pests
Apr 29, 2021 · Apt 1402AN
Close - Unsanitary condition
Pests
Dec 19, 2017 · Apt 1027
Close
Sales history
No recorded sales in our data
Building details
- Building type
- Hotel (H2)
- Year built
- 2012
- Floors
- 28
- Residential units
- —
- Building area
- 114,226 ft²
- Lot area
- 9,914 ft²
- Zoning
- C5-5
- Community board
- 101
- Council district
- 1
- Block / lot
- 69 / 30
- Assessed value
- $20,079,900
- Landmark / historic district
- No
HPD registration #144214, last renewed Jul 16, 2025.
Questions about 4 Platt Street
Who owns 4 Platt Street?
The owner of record in NYC Department of City Planning PLUTO data is Lam Platt Street Hotel LLC.
Does 4 Platt Street have violations?
Yes. NYC HPD has recorded 3 housing violations at this property.
Is 4 Platt Street rent stabilized?
No rent-stabilized units appear in its 2018–2024 tax bills. Individual apartments can still be regulated, so request the rent history from NYS Homes and Community Renewal if unsure.
When was 4 Platt Street built?
City records list 2012 as the year it was built.
Source: NYC Open Data (DCP PLUTO, HPD, DOB, ECB/OATH, DOF). Records can lag the city's systems. Data refreshed weekly.